{"title":"Fire Pit Burners \u0026 Components","description":"\u003cdiv class=\"mnk-col-intro\" data-mnk-col-layout=\"1\"\u003e\n\u003cp\u003eGas fire pit burner systems for building a fire pit or replacing an old burner. Choose a drop-in pan insert or a flat pan, round, square or linear, in natural gas or propane, then size it to your enclosure opening.\u003c\/p\u003e\n\u003cul class=\"mnk-col-cats\"\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/firegear\"\u003eFiregear\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/fire-pits-and-tables\"\u003eFire pits \u0026amp; fire tables\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-col-guide\"\u003e\n\u003ch2 id=\"inserts\"\u003eDrop-in fire pit inserts and pan kits\u003c\/h2\u003e\n\u003cp\u003eA burner system is the part of a gas fire pit you build around: a stainless pan, a burner, a gas valve and an ignition. Firegear Pro Series systems come in three shapes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in pan, round or square:\u003c\/strong\u003e a recessed pan with a 21-inch or 14-inch brass spur burner that drops into the top of your enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat pan, round or square:\u003c\/strong\u003e the same spur burners on a flat pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinear flat pan:\u003c\/strong\u003e 10-inch-wide pans in 30, 36, 48 and 60-inch lengths with an H-shaped burner, for long, narrow fire features.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"sizing\"\u003eHow to size a fire pit burner\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the opening, not the pan name.\u003c\/strong\u003e Each drop-in pan fits a specific opening range in the manual. For example, Firegear lists 32-1\/4 to 33 in. per side for its 32-inch square drop-in pan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompare heat output.\u003c\/strong\u003e Firegear rates its 26 to 33-inch Pro Series drop-in systems with a 21-inch spur at 175,000 BTU. The 36 x 10-inch linear system is rated 95,000 BTU on natural gas and 115,000 BTU on propane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder the right fuel.\u003c\/strong\u003e Each system is a separate natural gas (-N) or propane (-P) model, so match it to your gas supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the right media.\u003c\/strong\u003e Firegear calls for 1 to 2-inch lava rock, no deeper than 1 inch over the burner ports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"venting\"\u003eEnclosure venting and clearances\u003c\/h2\u003e\n\u003cp\u003eEvery enclosure needs cross ventilation, and every burner has minimum clearances to combustibles; both are set in the manual for your model (see the questions below). These burners are for outdoor use only. Have a qualified installer connect the gas, following the manufacturer's installation manual and local codes.\u003c\/p\u003e\n\u003ch2 id=\"faq\"\u003eFire pit burner questions\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I put a gas fire pit burner under a covered patio?\u003c\/summary\u003e\u003cp\u003eOnly if you can meet the manual's clearances. Firegear's Pro Series drop-in TPSI manual lists 120 inches to a combustible ceiling and 36 inches to a side wall, and says the burners are for outdoor use only, never in an enclosed space. Follow the manufacturer's installation manual and your local codes.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I convert a natural gas fire pit burner to propane?\u003c\/summary\u003e\u003cp\u003ePlan to order the fuel you need instead. Firegear sells each Pro Series system as a separate natural gas (-N) or propane (-P) model, and its manual does not cover converting one to the other. Have a qualified installer make the gas connection, following the manual and local codes.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDo I need to vent my fire pit enclosure?\u003c\/summary\u003e\u003cp\u003eYes. Firegear requires at least 18 square inches of cross ventilation on each side of the enclosure, with the vents on opposite sides, for example two 6 x 12-inch vents. Without it the warranty is void. Follow the manufacturer's installation manual and local codes for your build.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow much lava rock goes over a fire pit burner?\u003c\/summary\u003e\u003cp\u003eNo more than 1 inch over the burner ports. Firegear's Pro Series manual calls for 1 to 2-inch lava rock that covers the burner, and warns not to block the injectors. It gives no fire glass depth, so ask our team before switching to glass on these systems.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDoes TPSI ignition need electricity?\u003c\/summary\u003e\u003cp\u003eNo wiring is needed. TPSI uses a battery-powered piezo igniter (Firegear's manual shows a AAA battery) to light a standing pilot, and a thermocouple monitors the pilot flame. When lighting, hold the knob at PILOT for 30 to 60 seconds, as the manual describes.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e","products":[{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-N is a complete round fire pit burner system for natural gas: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003eFPB-19RPSBR14TPSI-P\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-N\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on natural gas:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (natural gas); burner part FG-PSBR-BS14-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series natural gas Spur burner (FG-PSBR-BS14-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951520535,"sku":"FPB-19RPSBR14TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fpb-19rpsbr14tpsi-n-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Propane Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-P is a complete round fire pit burner system for propane: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003eFPB-19RPSBR14TPSI-N\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-P\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on propane:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (propane); burner part FG-PSBR-BS14-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series propane Spur burner (FG-PSBR-BS14-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951618839,"sku":"FPB-19RPSBR14TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-fpb-19rpsbr14tpsi-p-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n","title":"Firegear Pro Series 20-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-20SPSBR14TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-20SPSBR14TPSI-N is a complete square fire pit burner system for natural gas: a 20-inch square stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p\"\u003eFPB-20SPSBR14TPSI-P\u003c\/a\u003e; for a round pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-N\u003c\/a\u003e (also 125,000 Btu), or for a larger square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 20-1\/4 to 21 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on natural gas:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest square Pro Series drop-in pan, rated the same as the 19-inch round drop-in; the 26-inch and larger square pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 20-1\/4 to 21-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-20SPSBR14TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e20 in. square stainless drop-in pan (PAN-SS20S), 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e20-1\/4 in. minimum to 21 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (natural gas); burner part FG-PSBR-BS14-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e20 in. square stainless drop-in pan (PAN-SS20S) with 14 in. Pro Series natural gas Spur burner (FG-PSBR-BS14-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with a 20-1\/4 to 21 in. opening (Firegear's ready-to-finish square enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 20-1\/4 to 21 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951717143,"sku":"FPB-20SPSBR14TPSI-N","price":1929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fpb-20spsbr14tpsi-n-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p","title":"Firegear Pro Series 20-Inch Square Drop-In Pan Propane Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-20SPSBR14TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-20SPSBR14TPSI-P is a complete square fire pit burner system for propane: a 20-inch square stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n\"\u003eFPB-20SPSBR14TPSI-N\u003c\/a\u003e; for a round pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-P\u003c\/a\u003e (also 125,000 Btu), or for a larger square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 20-1\/4 to 21 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on propane:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest square Pro Series drop-in pan, rated the same as the 19-inch round drop-in; the 26-inch and larger square pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 20-1\/4 to 21-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-20SPSBR14TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e20 in. square stainless drop-in pan (PAN-SS20S), 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e20-1\/4 in. minimum to 21 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (propane); burner part FG-PSBR-BS14-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e20 in. square stainless drop-in pan (PAN-SS20S) with 14 in. Pro Series propane Spur burner (FG-PSBR-BS14-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with a 20-1\/4 to 21 in. opening (Firegear's ready-to-finish square enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 20-1\/4 to 21 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951979287,"sku":"FPB-20SPSBR14TPSI-P","price":1929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-fpb-20spsbr14tpsi-p-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003eFPB-25RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-N\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952044823,"sku":"FPB-25RPSBR21TPSI-N","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fpb-25rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342504"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003eFPB-25RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-P\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952175895,"sku":"FPB-25RPSBR21TPSI-P","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-fpb-25rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n","title":"Firegear Pro Series 25-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 25-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003eFPB-25SFPSBR21TPSI-P\u003c\/a\u003e; for a larger square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch FPB-30SFPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch FPB-34SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 23 inches across and no larger than the 25-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 30 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, in the smallest square disc of the range, for a compact square pit or table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 25-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 23 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. square flat stainless disc (Pan-SS25SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e23 in. minimum; do not exceed the 25 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. square flat stainless disc (Pan-SS25SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with an opening of 23 to 25 in. (Firegear's ready-to-finish square enclosures are cut for larger discs; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 23 inches and no larger than the 25-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952241431,"sku":"FPB-25SFPSBR21TPSI-N","price":2029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fpb-25sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342514"},{"product_id":"firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p","title":"Firegear Pro Series 25-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 25-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003eFPB-25SFPSBR21TPSI-N\u003c\/a\u003e; for a larger square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch FPB-30SFPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch FPB-34SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 23 inches across and no larger than the 25-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 30 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, in the smallest square disc of the range, for a compact square pit or table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 25-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 23 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. square flat stainless disc (Pan-SS25SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e23 in. minimum; do not exceed the 25 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. square flat stainless disc (Pan-SS25SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with an opening of 23 to 25 in. (Firegear's ready-to-finish square enclosures are cut for larger discs; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 23 inches and no larger than the 25-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952339735,"sku":"FPB-25SFPSBR21TPSI-P","price":2029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-fpb-25sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n","title":"Firegear Pro Series 26-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003eFPB-26DPSBR21TPSI-P\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch FPB-29DPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003e34-inch FPB-34DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952372503,"sku":"FPB-26DPSBR21TPSI-N","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-fpb-26dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p","title":"Firegear Pro Series 26-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003eFPB-26DPSBR21TPSI-N\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch FPB-29DPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003e34-inch FPB-34DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952438039,"sku":"FPB-26DPSBR21TPSI-P","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-fpb-26dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n","title":"Firegear Pro Series 26-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26SPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26SPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 26-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003eFPB-26SPSBR21TPSI-P\u003c\/a\u003e; for a larger square pit see the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e or \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 26-1\/4 to 27 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 32-inch square and 25, 29 and 33-inch round Spur drop-in systems, in a square pan 6 inches smaller per side than the 32-inch square.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 26-1\/4 to 27-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26SPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. square stainless drop-in pan (PAN-SS26S), 26 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e26-1\/4 in. minimum to 27 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. square stainless drop-in pan (PAN-SS26S) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 26-1\/4 to 27 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 26-1\/4 to 27 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952569111,"sku":"FPB-26SPSBR21TPSI-N","price":2199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fpb-26spsbr21tpsi-n-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p","title":"Firegear Pro Series 26-Inch Square Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26SPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26SPSBR21TPSI-P is a complete square fire pit burner system for propane: a 26-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003eFPB-26SPSBR21TPSI-N\u003c\/a\u003e; for a larger square pit see the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e or \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 26-1\/4 to 27 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 32-inch square and 25, 29 and 33-inch round Spur drop-in systems, in a square pan 6 inches smaller per side than the 32-inch square.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 26-1\/4 to 27-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26SPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. square stainless drop-in pan (PAN-SS26S), 26 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e26-1\/4 in. minimum to 27 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. square stainless drop-in pan (PAN-SS26S) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 26-1\/4 to 27 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 26-1\/4 to 27 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634953322775,"sku":"FPB-26SPSBR21TPSI-P","price":2199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-fpb-26spsbr21tpsi-p-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003eFPB-29DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954076439,"sku":"FPB-29DPSBR21TPSI-N","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-fpb-29dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003eFPB-29DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954240279,"sku":"FPB-29DPSBR21TPSI-P","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-fpb-29dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003eFPB-29RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954305815,"sku":"FPB-29RPSBR21TPSI-N","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fpb-29rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003eFPB-29RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954404119,"sku":"FPB-29RPSBR21TPSI-P","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-fpb-29rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n","title":"Firegear Pro Series 30-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-30SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-30SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 30-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003eFPB-30SFPSBR21TPSI-P\u003c\/a\u003e; for other square flat-pan pits see the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003e25-inch FPB-25SFPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch FPB-34SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 28 inches across and no larger than the 30-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, so the 30-inch disc gives that output in a mid-size square pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 30-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 28 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-30SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e30 in. square flat stainless disc (PAN-SS30SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e28 in. minimum; do not exceed the 30 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 in. square flat stainless disc (PAN-SS30SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 28 to 30 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 28 inches and no larger than the 30-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954469655,"sku":"FPB-30SFPSBR21TPSI-N","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fpb-30sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342526"},{"product_id":"firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p","title":"Firegear Pro Series 30-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-30SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-30SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 30-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003eFPB-30SFPSBR21TPSI-N\u003c\/a\u003e; for other square flat-pan pits see the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003e25-inch FPB-25SFPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch FPB-34SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 28 inches across and no larger than the 30-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, so the 30-inch disc gives that output in a mid-size square pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 30-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 28 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-30SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e30 in. square flat stainless disc (PAN-SS30SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e28 in. minimum; do not exceed the 30 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 in. square flat stainless disc (PAN-SS30SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 28 to 30 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 28 inches and no larger than the 30-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954666263,"sku":"FPB-30SFPSBR21TPSI-P","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-fpb-30sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n","title":"Firegear Pro Series 32-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-32SPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-32SPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 32-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003eFPB-32SPSBR21TPSI-P\u003c\/a\u003e; for a smaller square pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 32-1\/4 to 33 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25, 29 and 33-inch round and 26-inch square Spur drop-in systems, spread over the largest square pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 32-1\/4 to 33-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-32SPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e32 in. square stainless drop-in pan (PAN-SS32S), 32 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32-1\/4 in. minimum to 33 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e32 in. square stainless drop-in pan (PAN-SS32S) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32-1\/4 to 33 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 32-1\/4 to 33 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954764567,"sku":"FPB-32SPSBR21TPSI-N","price":2359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fpb-32spsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p","title":"Firegear Pro Series 32-Inch Square Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-32SPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-32SPSBR21TPSI-P is a complete square fire pit burner system for propane: a 32-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003eFPB-32SPSBR21TPSI-N\u003c\/a\u003e; for a smaller square pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 32-1\/4 to 33 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25, 29 and 33-inch round and 26-inch square Spur drop-in systems, spread over the largest square pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 32-1\/4 to 33-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-32SPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e32 in. square stainless drop-in pan (PAN-SS32S), 32 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32-1\/4 in. minimum to 33 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e32 in. square stainless drop-in pan (PAN-SS32S) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32-1\/4 to 33 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 32-1\/4 to 33 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954928407,"sku":"FPB-32SPSBR21TPSI-P","price":2359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-fpb-32spsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003eFPB-33RPSBR21TPSI-P\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955026711,"sku":"FPB-33RPSBR21TPSI-N","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fpb-33rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003eFPB-33RPSBR21TPSI-N\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955125015,"sku":"FPB-33RPSBR21TPSI-P","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-fpb-33rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n","title":"Firegear Pro Series 34-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003eFPB-34DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955288855,"sku":"FPB-34DPSBR21TPSI-N","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-fpb-34dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p","title":"Firegear Pro Series 34-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003eFPB-34DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955354391,"sku":"FPB-34DPSBR21TPSI-P","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-fpb-34dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342537"},{"product_id":"firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n","title":"Firegear Pro Series 34-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 34-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003eFPB-34SFPSBR21TPSI-P\u003c\/a\u003e; for a smaller square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003e34-inch round flat pan FPB-34DPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e Firegear's largest square flat-pan Spur system, at the same rating as its 25 and 30-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. square flat stainless disc (PAN-SS34SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc size (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. square flat stainless disc (PAN-SS34SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955452695,"sku":"FPB-34SFPSBR21TPSI-N","price":2189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fpb-34sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342537"},{"product_id":"firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p","title":"Firegear Pro Series 34-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 34-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003eFPB-34SFPSBR21TPSI-N\u003c\/a\u003e; for a smaller square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003e34-inch round flat pan FPB-34DPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e Firegear's largest square flat-pan Spur system, at the same rating as its 25 and 30-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. square flat stainless disc (PAN-SS34SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc size (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. square flat stainless disc (PAN-SS34SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955518231,"sku":"FPB-34SFPSBR21TPSI-P","price":2189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-fpb-34sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342538"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-N is a complete linear fire pit burner system for natural gas: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 80,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003eLOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80,000 Btu\/hr on natural gas:\u003c\/strong\u003e the smallest of Firegear's flat H TPSI systems, sized for a 30-inch linear fire pit or fire table; the 36-inch version is rated 95,000 Btu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 20 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., 20 individual injectors (natural gas); burner part FG-PSBR-H24-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e80,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series natural gas H burner (FG-PSBR-H24-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 80,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959417623,"sku":"LOF-3010PS246TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-lof-3010ps246tpsi-n-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-P is a complete linear fire pit burner system for propane: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 110,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003eLOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e110,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 30-inch linear fire pit or fire table, with more output than the 80,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H24-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e110,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series propane H burner (FG-PSBR-H24-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959450391,"sku":"LOF-3010PS246TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-lof-3010ps246tpsi-p-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-N is a complete linear fire pit burner system for natural gas: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 95,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003eLOF-3610PS306TPSI-P\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003e30 x 10-inch LOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e95,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (80,000 Btu) and 48-inch (120,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 24 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., 24 individual injectors (natural gas); burner part FG-PSBR-H30-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e95,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series natural gas H burner (FG-PSBR-H30-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 95,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959515927,"sku":"LOF-3610PS306TPSI-N","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-lof-3610ps306tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-P is a complete linear fire pit burner system for propane: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 115,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003eLOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003e30 x 10-inch propane LOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e115,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (110,000 Btu) and 48-inch (150,000 Btu) propane flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H30-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e115,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series propane H burner (FG-PSBR-H30-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959581463,"sku":"LOF-3610PS306TPSI-P","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-lof-3610ps306tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-N is a complete linear fire pit burner system for natural gas: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 120,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003eLOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003e60 x 10-inch LOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e120,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, between Firegear's 36-inch (95,000 Btu) and 60-inch (160,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 32 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., 32 individual injectors (natural gas); burner part FG-PSBR-H40-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e120,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series natural gas H burner (FG-PSBR-H40-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959614231,"sku":"LOF-4810PS406TPSI-N","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-lof-4810ps406tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-P is a complete linear fire pit burner system for propane: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 150,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003eLOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003e60 x 10-inch propane LOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, with more output than the 120,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H40-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e150,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series propane H burner (FG-PSBR-H40-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959646999,"sku":"LOF-4810PS406TPSI-P","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-lof-4810ps406tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-N is a complete linear fire pit burner system for natural gas: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 160,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors (40 on this natural gas model) instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003eLOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear does not offer conversion kits for Pro Series systems. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160,000 Btu\/hr on natural gas:\u003c\/strong\u003e the highest output of Firegear's 10-inch-wide Pro Series flat H systems, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 40 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete gas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, 40 individual injectors (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e160,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted (propane model LOF-6010PS506TPSI-P, 175,000 Btu\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series natural gas H burner\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for runs over 20 ft on units above 100,000 Btu; its product guide chart shows 3\/4 in. pipe at its 160,000 Btu limit on a 20 ft run, so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959712535,"sku":"LOF-6010PS506TPSI-N","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-lof-6010ps506tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-P is a complete linear fire pit burner system for propane: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003eLOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the highest rating in Firegear's Pro Series flat H TPSI model table, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in. (pan 78127)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, multiple individual brass injectors (propane); burner part FG-PSBR-H50-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series propane H burner (FG-PSBR-H50-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959745303,"sku":"LOF-6010PS506TPSI-P","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-lof-6010ps506tpsi-p-burner-and-gas.jpg?v=1794342538"}],"url":"https:\/\/mnkgrills.com\/collections\/fire-pit-burners-components.oembed?page=2","provider":"M\u0026K Grills","version":"1.0","type":"link"}