{"title":"Firegear All Weather Ignition Systems","description":"\u003cdiv data-mnk-col-layout\u003e\u003cp\u003eThe Firegear All Weather System (AWS) is an electronic fire pit ignition system built for demanding projects, from a single fire feature to groups of up to four, including features near a pool or spa. We carry the single-feature kit and 290K and 715K BTU 30VDC valve systems, each in natural gas or propane.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"mnk-col-guide\"\u003e\n\u003ch2 id=\"aws-options\"\u003eFiregear AWS options\u003c\/h2\u003e\n\u003cp\u003eFiregear sets which AWS configuration a project needs by the number of fire features and their distance from a pool or spa. The kits below come from the Firegear model numbers.\u003c\/p\u003e\n\u003cdiv class=\"mnk-table-wrap\"\u003e\n\u003ctable class=\"mnk-compare\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eListed as\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eGas versions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFG-AWS30VDC-GOEK\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n\"\u003eAll Weather ignition system for a single fire feature\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirm with us\u003c\/td\u003e\n\u003ctd\u003e-N natural gas, -P propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFG-AWS30VDC-K\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n\"\u003e30VDC All Weather valve system\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e290,000 BTU\u003c\/td\u003e\n\u003ctd\u003e-N, -P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFG-AWS30VDC-HC-K\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-715k-btu-high-capacity-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-hc-k-n\"\u003eHigh Capacity 30VDC All Weather valve system\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e715,000 BTU\u003c\/td\u003e\n\u003ctd\u003e-N, -P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"choosing-aws\"\u003eWhich AWS setup do you need?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle fire feature:\u003c\/strong\u003e Firegear says the single-feature AWS can only be installed in fire features more than 10 feet from a pool or spa, and all its components can be housed under the burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple features or near water:\u003c\/strong\u003e Firegear's multiple-feature AWS is used for 1 to 4 fire features, and for any fire feature within 5 feet of a pool or spa. It needs one kit per fire feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e the multiple-feature setup needs one power supply, sold separately, for every 4 fire features. Ask us which power supply and kit match your project.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner capacity:\u003c\/strong\u003e the 290K and 715K figures in the model names are each valve system's BTU rating. Send us your burner model and we will confirm which one fits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGo back to \u003ca href=\"\/collections\/firegear\"\u003eall Firegear products\u003c\/a\u003e, or compare \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components from every brand\u003c\/a\u003e. Not sure which size fits your fire pit? Send us your measurements and photos and we will help.\u003c\/p\u003e\n\u003ch2 id=\"faq\"\u003eFiregear AWS FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eCan a Firegear AWS be used next to a pool?\u003c\/summary\u003e\u003cp\u003eFiregear says fire features within 5 feet of a pool or spa use its multiple-feature AWS setup, and that the single-feature AWS can only be installed more than 10 feet from a pool or spa. Confirm your layout with us and follow the AWS manual.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow many fire features can one AWS run?\u003c\/summary\u003e\u003cp\u003eFiregear lists its multiple-feature AWS for 1 to 4 fire features, with one kit per fire feature and one separately sold power supply for every 4 features.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich AWS valve system should I choose?\u003c\/summary\u003e\u003cp\u003eWe carry the 290,000 BTU valve system and the 715,000 BTU High Capacity version. Which one your project needs depends on your burner, so send us the burner model and we will confirm.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the AWS sold for natural gas and propane?\u003c\/summary\u003e\u003cp\u003eYes. Each AWS kit we carry is a separate natural gas (-N) or propane (-P) model.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat clearances and venting does a Firegear burner need?\u003c\/summary\u003e\u003cp\u003eClearances to combustibles, enclosure ventilation and fire media depth are set in the Firegear installation and operating manual for each burner system. We could not confirm those figures for this page, so confirm with us before you build: we will send the Firegear manual for your exact model, and the manual's requirements govern the install.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n","title":"Firegear Natural Gas All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Single Fire Feature ignition kit for natural gas, model FG-AWS30VDC-GOEK-N: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in one custom-built gas fire pit or fire feature. It ships with its own GOE-30VDC power supply, which plugs into a 120VAC GFI outlet and converts it to 30VDC for the valve, so a single feature needs no separate power supply. Firegear's product guide notes that all of the kit's components can be housed underneath the burner.\u003c\/p\u003e\n\u003cp\u003eThe system is rated for up to 290,000 Btu\/hr at the burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. You turn it on and off with the weatherproof rocker switch on the faceplate, or add an optional remote, wall switch, timer or emergency stop.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this kit is for \u003cstrong\u003eone\u003c\/strong\u003e fire feature only, installed at least 10 feet from a pool or spa. For two to four features, or any feature within 5 feet of a pool or spa, Firegear specifies the \u003ca href=\"\/products\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n\"\u003eAWS multiple fire feature kit (FG-AWS30VDC-K-N)\u003c\/a\u003e with the FG-AWS-PS-30V320 pool-certified power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The propane version is FG-AWS30VDC-GOEK-P.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply included:\u003c\/strong\u003e the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-GOEK-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSingle fire feature ignition kit (power supply included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOne fire feature, installed 10 ft or more from a pool or spa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; Firegear notes only natural gas models can be converted to propane, by changing the pilot orifice (FG-AWS-PBO-P) and the main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eGOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eGOE-30VDC power supply for one fire feature\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-NG orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003ePropane conversion: pilot orifice kit FG-AWS-PBO-P plus a propane main burner orifice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Do not install the kit without a main burner orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-single-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Single Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947719447,"sku":"FG-AWS30VDC-GOEK-N","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-natural-gas-all-weather-ignition-system-for-single-fg-aws30vdc-goek-n-kit-components.jpg?v=1794342503"},{"product_id":"firegear-propane-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-p","title":"Firegear Propane All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Single Fire Feature ignition kit for propane, model FG-AWS30VDC-GOEK-P: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in one custom-built gas fire pit or fire feature. It ships with its own GOE-30VDC power supply, which plugs into a 120VAC GFI outlet and converts it to 30VDC for the valve, so a single feature needs no separate power supply. Firegear's product guide notes that all of the kit's components can be housed underneath the burner.\u003c\/p\u003e\n\u003cp\u003eThe system is rated for up to 290,000 Btu\/hr at the burner, and Firegear's propane orifice table runs from 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12). A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. You turn it on and off with the weatherproof rocker switch on the faceplate, or add an optional remote, wall switch, timer or emergency stop.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this kit is for \u003cstrong\u003eone\u003c\/strong\u003e fire feature only, installed at least 10 feet from a pool or spa. For two to four features, or any feature within 5 feet of a pool or spa, Firegear specifies the \u003ca href=\"\/products\/firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p\"\u003eAWS multiple fire feature kit for propane (FG-AWS30VDC-K-P)\u003c\/a\u003e with the FG-AWS-PS-30V320 pool-certified power supply. Propane needs its own planning: Firegear requires ventilation and drainage at the bottom of the feature, an LP tank of at least 100 lb kept outside the enclosure, and a 3-inch nipple in the burner ahead of the propane orifice. Order the fuel you will use: Firegear states that only natural gas models can be converted to propane. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The natural gas version is the \u003ca href=\"\/products\/firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n\"\u003eFG-AWS30VDC-GOEK-N\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply included:\u003c\/strong\u003e the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet up for propane:\u003c\/strong\u003e propane pilot orifice (FG-PBO-LP) on the pilot, with Firegear's LP orifice table (OAS-LP41 to OAS-LP12) for sizing the main burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-GOEK-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSingle fire feature ignition kit (power supply included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOne fire feature, installed 10 ft or more from a pool or spa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; propane orifice table 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane (LP). Models are ordered as natural gas or propane; Firegear states only natural gas models can be converted to propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi), low-pressure LP after regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLP supply\u003c\/th\u003e\n\u003ctd\u003eTank of 100 lb capacity or more, located outside the fire pit enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain burner orifice\u003c\/th\u003e\n\u003ctd\u003eNot included; LP orifices have vent holes at the base, and propane installs need a 3\" nipple in the burner before the orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with LP pilot orifice (FG-PBO-LP) and thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eGOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, LP tank and regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003ePilot burner assembly (FG-PBA) set up for propane, with heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eGOE-30VDC power supply for one fire feature\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA fire pit pan and burner, and the propane main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side); for propane, vents go at the bottom of the feature\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003eReplacement LP pilot orifice FG-PBO-LP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003ePropane ventilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure, at the bottom of the feature. Propane is heavier than air and settles, so Firegear requires drainage and ventilation at the bottom and a vent or drain line so gas cannot collect. Firegear states that failure to provide proper ventilation voids the warranty.\u003c\/li\u003e\n\u003cli\u003eLP tank: use a tank of at least 100 lb capacity, keep every LP tank outside the enclosure, and do not store an LP cylinder that is not connected near this or any other appliance.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner ports facing up, the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's LP pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi. Install a 3\" nipple in the burner before the LP orifice, and never run the kit without a main burner orifice. If the wrong pilot orifice is fitted, the pilot will not light.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-single-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Single Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947752215,"sku":"FG-AWS30VDC-GOEK-P","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-propane-all-weather-ignition-system-for-single-fg-aws30vdc-goek-p-kit-components-chart.jpg?v=1794342543"},{"product_id":"firegear-715k-btu-high-capacity-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-hc-k-n","title":"Firegear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System - FG-AWS30VDC-HC-K-N","description":"\u003ch2\u003eFiregear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System\u003c\/h2\u003e\n\u003cp\u003eA gas valve component for gas fire pits and fire features that controls the gas flow to the burner.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eThe Firegear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System controls the gas flow to the burner.\u003c\/p\u003e\n\u003cp\u003eHandles up to 715,000 BTU. 3\/4\" FIP gas inlet. Confirm compatibility with your burner system before ordering.\u003c\/p\u003e\n\u003cp\u003eGas and electrical connections should be made by a licensed professional following local codes.\u003c\/p\u003e\n\u003cp\u003eNot sure it works with your system? Send us your burner model and our team will confirm compatibility. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve component for gas fire features\u003c\/li\u003e\n\u003cli\u003eWeatherproof housing\u003c\/li\u003e\n\u003cli\u003e715,000 BTU capacity\u003c\/li\u003e\n\u003cli\u003eNatural gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-HC-K-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eGas valve component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e715,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight (as listed by distributor)\u003c\/th\u003e\n\u003ctd\u003e12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947784983,"sku":"FG-AWS30VDC-HC-K-N","price":4489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-715k-btu-high-capacity-natural-gas-30vdc-all-fg-aws30vdc-hc-k-n-kit-components-chart.jpg?v=1794342490"},{"product_id":"firegear-715k-btu-high-capacity-propane-30vdc-all-weather-valve-system-fg-aws30vdc-hc-k-p","title":"Firegear 715K BTU High Capacity Propane 30VDC All Weather Valve System - FG-AWS30VDC-HC-K-P","description":"\u003ch2\u003eFiregear 715K BTU High Capacity Propane 30VDC All Weather Valve System\u003c\/h2\u003e\n\u003cp\u003eA gas valve component for gas fire pits and fire features that controls the gas flow to the burner.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eThe Firegear 715K BTU High Capacity Propane 30VDC All Weather Valve System controls the gas flow to the burner.\u003c\/p\u003e\n\u003cp\u003eHandles up to 715,000 BTU. 3\/4\" FIP gas inlet. Confirm compatibility with your burner system before ordering.\u003c\/p\u003e\n\u003cp\u003eGas and electrical connections should be made by a licensed professional following local codes.\u003c\/p\u003e\n\u003cp\u003eNot sure it works with your system? Send us your burner model and our team will confirm compatibility. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve component for gas fire features\u003c\/li\u003e\n\u003cli\u003eWeatherproof housing\u003c\/li\u003e\n\u003cli\u003e715,000 BTU capacity\u003c\/li\u003e\n\u003cli\u003ePropane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-HC-K-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eGas valve component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e715,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight (as listed by distributor)\u003c\/th\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947948823,"sku":"FG-AWS30VDC-HC-K-P","price":4489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-715k-btu-high-capacity-propane-30vdc-all-weather-fg-aws30vdc-hc-k-p-kit-components.jpg?v=1794342490"},{"product_id":"firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n","title":"Firegear 290K BTU Natural Gas 30VDC All Weather Valve System - FG-AWS30VDC-K-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Multiple Fire Feature valve kit for natural gas, model FG-AWS30VDC-K-N: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in a custom-built gas fire pit or fire feature. It is the kit Firegear specifies when you run one to four fire features from one power supply, and for any fire feature within 5 feet of a pool or spa. One kit goes in each fire feature.\u003c\/p\u003e\n\u003cp\u003eEach kit is rated for up to 290,000 Btu\/hr at its burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu; one valve can serve a linear burner from 24 inches up to 14 feet long. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. Turn it on with the faceplate rocker switch, or with an optional remote, wall switch, timer or emergency stop; on a switched supply the feature turns on when power is applied and off when it is removed.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: the power supply is \u003cstrong\u003enot included\u003c\/strong\u003e. Each FG-AWS-PS-30V320 30VDC pool-certified power supply runs up to four fire features up to 500 feet away. For a single feature at least 10 feet from a pool or spa, the \u003ca href=\"\/products\/firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n\"\u003esingle fire feature kit (FG-AWS30VDC-GOEK-N)\u003c\/a\u003e includes its own power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The propane version is FG-AWS30VDC-K-P.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for multiple features and pools:\u003c\/strong\u003e up to four fire features share one FG-AWS-PS-30V320 supply up to 500 feet away, and it is the kit Firegear specifies within 5 feet of a pool or spa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-K-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eMultiple fire feature valve kit (power supply not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003e1 to 4 fire features per power supply, and any feature within 5 ft of a pool or spa; one kit per fire feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; Firegear notes only natural gas models can be converted to propane, by changing the pilot orifice (FG-AWS-PBO-P) and the main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eNot included: FG-AWS-PS-30V320 (30VDC, 320 W pool-certified; output +30 V, 10.7 A), up to 4 features up to 500 ft away\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eFG-AWS-PS-30V320 30VDC pool-certified power supply (required; one per four fire features); ask us to order\u003c\/li\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-NG orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003ePropane conversion: pilot orifice kit FG-AWS-PBO-P plus a propane main burner orifice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Do not install the kit without a main burner orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. Features within 5 ft of a pool or spa require the FG-AWS-PS-30V320 low-voltage supply, set at least 10 ft from the water, with the junction box and gas pipe bonded with 8 AWG or larger copper. Keep polarity the same on every daisy-chained feature (four maximum).\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-multiple-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Multiple Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634948014359,"sku":"FG-AWS30VDC-K-N","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n-kit-components.jpg?v=1794342478"},{"product_id":"firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p","title":"Firegear 290K BTU Propane 30VDC All Weather Valve System - FG-AWS30VDC-K-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Multiple Fire Feature valve kit for propane (LP), model FG-AWS30VDC-K-P: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in a custom-built gas fire pit or fire feature. It is the kit Firegear specifies when you run one to four fire features from one power supply, and for any fire feature within 5 feet of a pool or spa. One kit goes in each fire feature.\u003c\/p\u003e\n\u003cp\u003eEach kit is rated for up to 290,000 Btu\/hr at its burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu; one valve can serve a linear burner from 24 inches up to 14 feet long. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. Turn it on with the faceplate rocker switch, or with an optional remote, wall switch, timer or emergency stop; on a switched supply the feature turns on when power is applied and off when it is removed.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: the power supply is \u003cstrong\u003enot included\u003c\/strong\u003e. Each FG-AWS-PS-30V320 30VDC pool-certified power supply runs up to four fire features up to 500 feet away. For a single feature at least 10 feet from a pool or spa, the \u003ca href=\"\/products\/firegear-propane-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-p\"\u003esingle fire feature kit (FG-AWS30VDC-GOEK-P)\u003c\/a\u003e includes its own power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The natural gas version is FG-AWS30VDC-K-N.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for multiple features and pools:\u003c\/strong\u003e up to four fire features share one FG-AWS-PS-30V320 supply up to 500 feet away, and it is the kit Firegear specifies within 5 feet of a pool or spa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-K-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eMultiple fire feature valve kit (power supply not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003e1 to 4 fire features per power supply, and any feature within 5 ft of a pool or spa; one kit per fire feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eNot included: FG-AWS-PS-30V320 (30VDC, 320 W pool-certified; output +30 V, 10.7 A), up to 4 features up to 500 ft away\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003ePropane pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eFG-AWS-PS-30V320 30VDC pool-certified power supply (required; one per four fire features); ask us to order\u003c\/li\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Never place an LP tank inside the enclosure; Firegear's instructions call for a tank of at least 100 lb outside it. Propane installs need a 3\" nipple in the burner before the LP orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. Features within 5 ft of a pool or spa require the FG-AWS-PS-30V320 low-voltage supply, set at least 10 ft from the water, with the junction box and gas pipe bonded with 8 AWG or larger copper. Keep polarity the same on every daisy-chained feature (four maximum).\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-multiple-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Multiple Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634948112663,"sku":"FG-AWS30VDC-K-P","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p-kit-components-chart.jpg?v=1794342478"}],"url":"https:\/\/mnkgrills.com\/collections\/firegear-fire-pit-ignition-systems.oembed","provider":"M\u0026K Grills","version":"1.0","type":"link"}