{"title":"Firegear Linear Fire Pit Burners","description":"\u003cdiv data-mnk-col-layout\u003e\u003cp\u003eFiregear linear fire pit burners spread a line of flame along long fire tables, troughs and rectangular pits. Choose a Pro Series flat-pan system from 30 to 60 inches long with TPSI safety ignition, or the 80-inch H-burner kit for larger builds. Each comes as a separate natural gas or propane model.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"mnk-col-guide\"\u003e\n\u003ch2 id=\"linear-sizes\"\u003eFiregear linear burner sizes\u003c\/h2\u003e\n\u003cp\u003eFiregear groups its H and T burners under its linear burner systems. Sizes below come from the Firegear model numbers; each is sold as a natural gas and a propane model.\u003c\/p\u003e\n\u003cdiv class=\"mnk-table-wrap\"\u003e\n\u003ctable class=\"mnk-compare\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModel\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePan or kit\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIgnition\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eGas versions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003eLOF-3010PS246TPSI\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eLinear flat pan system\u003c\/td\u003e\n\u003ctd\u003e30 x 10 inches\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e-N natural gas, -P propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003eLOF-3610PS306TPSI\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eLinear flat pan system\u003c\/td\u003e\n\u003ctd\u003e36 x 10 inches\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e-N, -P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003eLOF-4810PS406TPSI\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eLinear flat pan system\u003c\/td\u003e\n\u003ctd\u003e48 x 10 inches\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e-N, -P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e\u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003eLOF-6010PS506TPSI\u003c\/a\u003e\u003c\/th\u003e\n\u003ctd\u003eLinear flat pan system\u003c\/td\u003e\n\u003ctd\u003e60 x 10 inches\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e-N, -P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFG-PSBR-H80\u003c\/th\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk\"\u003eH-burner kit\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e80 x 6.75 inches\u003c\/td\u003e\n\u003ctd\u003eConfirm with us\u003c\/td\u003e\n\u003ctd\u003eNGK natural gas, LPK propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"choosing-linear\"\u003eChoosing a linear Firegear burner\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e pick the system that fits the inside length of your table or trough. The flat-pan systems run 30, 36, 48 and 60 inches; the H-burner kit is 80 inches long.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete system or kit:\u003c\/strong\u003e the LOF systems include the pan and TPSI ignition. The H-burner kit is the burner assembly; ask us what else your build needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e Firegear lists its H-shaped Pro Series burners from 24 to 80 inches long and 80,000 to 250,000 BTU. Confirm the rating of your exact model with us.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Firegear makes \u003ca href=\"\/collections\/firegear-fire-pit-enclosures\"\u003elinear ready-to-finish enclosures\u003c\/a\u003e from 42 to 108 inches long.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGo back to \u003ca href=\"\/collections\/firegear\"\u003eall Firegear products\u003c\/a\u003e, or compare \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components from every brand\u003c\/a\u003e. Not sure which size fits your fire pit? Send us your measurements and photos and we will help.\u003c\/p\u003e\n\u003ch2 id=\"faq\"\u003eFiregear linear burner FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the difference between the LOF systems and the H-burner kit?\u003c\/summary\u003e\u003cp\u003eThe LOF models are complete linear flat-pan burner systems with TPSI ignition, 30 to 60 inches long. The FG-PSBR-H80 is an 80 x 6.75-inch Pro Series H-burner kit. Ask us which parts the H-burner kit needs for your fire feature.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow does Firegear TPSI ignition work?\u003c\/summary\u003e\u003cp\u003eTPSI stands for Thermocouple Piloted Safety Ignition. Firegear says the thermocouple-piloted safety valve turns the gas off if the flame is lost, and a battery spark igniter is included. You hold the igniter button, press and turn the knob to pilot, keep the knob pressed 30 to 60 seconds, then turn it to ON once the pilot is lit.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I convert a Firegear burner from propane to natural gas?\u003c\/summary\u003e\u003cp\u003eOrder the gas type you have, because each Firegear system on this page is sold as a separate natural gas or propane model. Firegear sells propane conversion kits matched to burner BTU, but whether your model can be converted, and who must do it, is set by its manual. Confirm with us before ordering.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat clearances and venting does a Firegear burner need?\u003c\/summary\u003e\u003cp\u003eClearances to combustibles, enclosure ventilation and fire media depth are set in the Firegear installation and operating manual for each burner system. We could not confirm those figures for this page, so confirm with us before you build: we will send the Firegear manual for your exact model, and the manual's requirements govern the install.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty do Firegear Pro Series burners have?\u003c\/summary\u003e\u003cp\u003eFiregear states that its Pro Series burners carry a limited lifetime warranty on parts and components. Terms and exclusions are in Firegear's warranty document; confirm with us for the coverage on your model.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk","title":"Firegear Pro Series 80 x 6.75-Inch Propane H-Burner Kit - FG-PSBR-H80-LPK","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FG-PSBR-H80-LPK is an 80 x 6-3\/4 inch brass H burner kit for propane, rated at 240,000 Btu\/hr, for long linear fire pits and fire tables that you or your builder make. The kit pairs Firegear's Pro Series H burner, which feeds the flame through 64 individual brass injectors instead of a single orifice, with a manual key valve, a 12-inch chrome key and a 46-inch stainless flex line. It is lit by hand: you hold a long match or butane lighter at the burner and open the key valve.\u003c\/p\u003e\n\u003cp\u003eThis is the longest H burner in Firegear's Pro Series range, which runs from 24 to 80 inches. It mounts on brass supports in a stainless pan or disc that you supply, with an inside size of at least 80 x 10 inches and a depth of 2-1\/2 to 3 inches; Firegear lists its 84 x 16 inch linear flat pan (78053) for the 80-inch burner. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk\"\u003eFG-PSBR-H80-NGK\u003c\/a\u003e, rated at 250,000 Btu\/hr. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors, and its Pro Series burners have no conversion kit, so choose the gas type before you order. This kit has no pilot, flame-sensing safety valve or electronic ignition. The burner pan, the enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e240,000 Btu\/hr on propane:\u003c\/strong\u003e the highest-rated burner in Firegear's Pro Series H range, sized for a long linear fire feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e64 brass injectors:\u003c\/strong\u003e the Pro Series H burner spreads its flame across many individual injectors (size #72, 0.025 in. on propane) for a fuller flame along the full 80-inch length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey valve kit:\u003c\/strong\u003e a manual key valve (BVL2S) with a chrome flange cover and a 12-inch chrome key lets you set the flame from the side of the enclosure, with no wiring or batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46-inch stainless flex line in the box:\u003c\/strong\u003e connects the key valve to the burner fitting, so you only bring the supply line to a shut-off valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass supports and hardware:\u003c\/strong\u003e the burner bolts to your stainless pan, so it stays level and centered under the media.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series H burners and kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-PSBR-H80-LPK (propane kit); burner only: FG-PSBR-H80-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear H burner kit with manual key valve (match-lit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e80 x 6-3\/4 in. Pro Series brass H burner; replacement burner part 10808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjectors\u003c\/th\u003e\n\u003ctd\u003e64, size #72 (0.025 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e240,000 Btu\/hr (70.33 kW), rated at 11.0 in. WC at the burner orifice; flex line and pipe sizing can change the actual output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models, no conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 10.5 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eManual: long match or butane lighter at the burner while opening the key valve; no pilot or flame safety device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eManual key valve BVL2S with chrome flange cover CVR-BVL2CP and 12 in. chrome key KEY-PC-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e46 in. stainless flex line (T200-9898-46) to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner pan (not included)\u003c\/th\u003e\n\u003ctd\u003eStainless, 16 gauge recommended; at least 80 x 10 in. inside, 2-1\/2 to 3 in. deep; Firegear lists the 84 x 16 in. linear flat pan 78053 for this burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKey valve mounting\u003c\/th\u003e\n\u003ctd\u003e1-1\/4 in. round hole in the enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation on opposite sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor; the manual's diagram shows a 24 in. maximum overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003eLava rock or lava stone, 1 in. or larger at the base, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eBurner pan, enclosure, manual shut-off valve, vents, fire media, propane tank and regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e80 x 6-3\/4 in. Pro Series brass H burner, propane (10808)\u003c\/li\u003e\n\u003cli\u003e3\/8 in. x 2 in. stainless nipple (10858) and 1\/2 in. flare to 3\/8 in. FIP fitting (46-86)\u003c\/li\u003e\n\u003cli\u003eBrass burner supports with screws, nuts and washers (10850)\u003c\/li\u003e\n\u003cli\u003eManual key valve (BVL2S) with chrome flange cover (CVR-BVL2CP) and 12 in. chrome key (KEY-PC-12)\u003c\/li\u003e\n\u003cli\u003e46 in. stainless flex gas line (T200-9898-46) and 1\/2 in. flare to 1\/2 in. MIP fitting (U1-8D-S)\u003c\/li\u003e\n\u003cli\u003eFiregear Pro H-Burners and Kits installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eStainless burner pan or disc, at least 80 x 10 in. inside and 2-1\/2 to 3 in. deep, with 1\/4 in. drain holes; Firegear lists its 84 x 16 in. linear flat pan 78053 for this burner (ask us)\u003c\/li\u003e\n\u003cli\u003eA non-combustible linear enclosure, with a 1-1\/4 in. hole for the key valve\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. on opposite sides, for example two 6 x 12 in. vents per side\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock or lava stone, 1 in. or larger at the base\u003c\/li\u003e\n\u003cli\u003ePropane supply: tank and regulator, planned with your gas supplier (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch the fire pit. Do not set it directly on grass, dirt or rocks, keep it level, and build in drainage. Do not fill the enclosure cavity with gravel, rock or sand.\u003c\/li\u003e\n\u003cli\u003eBurner pan: Firegear recommends a 16 gauge stainless pan with 1\/4 in. drain holes and a center hole of at least 7\/8 in. Fit the nipple to the burner with gas-rated thread sealant, fit the brass supports on the legs about 2 in. from each end, mark and drill 1\/4 in. holes in the pan and fasten the supports with the screws, nuts and washers (5\/32 in. Allen wrench). Flared fittings need no sealant.\u003c\/li\u003e\n\u003cli\u003eKey valve: mount it through a 1-1\/4 in. round hole in the enclosure wall; a 1-1\/4 x 2 in. black iron nipple can be used as a spacer. Connect the 46 in. flex line between the valve and the burner fitting without kinking it.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on opposite sides of the enclosure, for example three 2 x 3 in. slots, two 1 x 9 in. slots or two 6 x 12 in. vents per side. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a ceiling and 18 in. to a floor; the manual's diagram shows a 24 in. maximum overhang.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior wall, with a 1\/2 in. male flare fitting for the flex line. Size the supply pipe to NFPA 54 or local code, adding about 5 ft of equivalent length for each fitting; Firegear's charts are for reference only, so at 240,000 Btu\/hr have a licensed plumber or gas fitter size the line. Isolate the appliance for pressure tests at or below 1\/2 psi (3.5 kPa) and leak-test every connection with soapy water before use. Plan the propane supply and regulator with your gas supplier; the kit does not include a regulator or tank, and Firegear says never to store an LP cylinder that is not connected for use near this or any other appliance.\u003c\/li\u003e\n\u003cli\u003eMedia: use lava rock or lava stone at least 1 in. across as the base, never stone or river rock. Place it loosely by hand, not poured from the bag or packed tight, cover the burner completely so it is not visible but no more than about 1 in. above it, and never block the injectors. Avoid materials that absorb moisture and release it slowly.\u003c\/li\u003e\n\u003cli\u003eLighting: insert the key and seat it, hold a lit long match or butane lighter near the end of the burner, then slowly turn the key counter-clockwise to ON. If the burner does not light within 10 seconds, turn the key clockwise to off, remove excess media, wait 5 minutes and try again. To shut down, turn the key clockwise until it stops and fit the cover once the unit has cooled.\u003c\/li\u003e\n\u003cli\u003eWeather: after heavy rain let the fire pit dry out before use. In wet conditions media can crack or pop; watch it from a distance for at least 30 minutes after lighting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the fire pit before first use and at least once a year. Clean the injectors with compressed air, wearing eye protection, and replace an injector if debris or nests will not clear. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Never leave it unattended, use it for cooking or burn solid fuels in it, and do not use it if it has been under water until a technician has inspected it. Do not store it indoors unless it is disconnected from the gas supply.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component; its Pro H-Burner instructions give no term in years, so ask us to confirm the term for the burner and key valve before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support. Not covered: accident, misuse, improper installation or maintenance, severe weather, chemical exposure, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification voids all warranties, and installation without proper ventilation voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/4-Burners-Burner-Kits\/Burners-and-Burner-Kits_Pro_H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Outdoor Fire Pit Pro H-Burners and Kits, installation and operating instructions, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/burners-and-kits\/h-pro-burners\" target=\"_blank\" rel=\"noopener\"\u003eFiregear H Pro Burners product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (chromium). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634949521687,"sku":"FG-PSBR-H80-LPK","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk-burner-and-gas-fitting.jpg?v=1794342543"},{"product_id":"firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk","title":"Firegear Pro Series 80 x 6.75-Inch Natural Gas H-Burner Kit - FG-PSBR-H80-NGK","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FG-PSBR-H80-NGK is an 80 x 6-3\/4 inch brass H burner kit for natural gas, rated at 250,000 Btu\/hr, for long linear fire pits and fire tables that you or your builder make. The kit pairs Firegear's Pro Series H burner, which feeds the flame through 64 individual brass injectors instead of a single orifice, with a manual key valve, a 12-inch chrome key and a 46-inch stainless flex line. It is lit by hand: you hold a long match or butane lighter at the burner and open the key valve.\u003c\/p\u003e\n\u003cp\u003eThis is the longest H burner in Firegear's Pro Series range, which runs from 24 to 80 inches. It mounts on brass supports in a stainless pan or disc that you supply, with an inside size of at least 80 x 10 inches and a depth of 2-1\/2 to 3 inches; Firegear lists its 84 x 16 inch linear flat pan (78053) for the 80-inch burner. The propane version is \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk\"\u003eFG-PSBR-H80-LPK\u003c\/a\u003e, rated at 240,000 Btu\/hr. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors, and its Pro Series burners have no conversion kit, so choose the gas type before you order. This kit has no pilot, flame-sensing safety valve or electronic ignition. The burner pan, the enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250,000 Btu\/hr on natural gas:\u003c\/strong\u003e the highest-rated burner in Firegear's Pro Series H range, sized for a long linear fire feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e64 brass injectors:\u003c\/strong\u003e the Pro Series H burner spreads its flame across many individual injectors (size #68, 0.031 in. on natural gas) for a fuller flame along the full 80-inch length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey valve kit:\u003c\/strong\u003e a manual key valve (BVL2S) with a chrome flange cover and a 12-inch chrome key lets you set the flame from the side of the enclosure, with no wiring or batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46-inch stainless flex line in the box:\u003c\/strong\u003e connects the key valve to the burner fitting, so you only bring the supply line to a shut-off valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass supports and hardware:\u003c\/strong\u003e the burner bolts to your stainless pan, so it stays level and centered under the media.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series H burners and kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-PSBR-H80-NGK (natural gas kit); burner only: FG-PSBR-H80-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear H burner kit with manual key valve (match-lit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e80 x 6-3\/4 in. Pro Series brass H burner; replacement burner part 10635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjectors\u003c\/th\u003e\n\u003ctd\u003e64, size #68 (0.031 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e250,000 Btu\/hr (73.27 kW), rated at 7.0 in. WC at the burner orifice; flex line and pipe sizing can change the actual output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models, no conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 5.0 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eManual: long match or butane lighter at the burner while opening the key valve; no pilot or flame safety device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eManual key valve BVL2S with chrome flange cover CVR-BVL2CP and 12 in. chrome key KEY-PC-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e46 in. stainless flex line (T200-9898-46) to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner pan (not included)\u003c\/th\u003e\n\u003ctd\u003eStainless, 16 gauge recommended; at least 80 x 10 in. inside, 2-1\/2 to 3 in. deep; Firegear lists the 84 x 16 in. linear flat pan 78053 for this burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKey valve mounting\u003c\/th\u003e\n\u003ctd\u003e1-1\/4 in. round hole in the enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation on opposite sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor; the manual's diagram shows a 24 in. maximum overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003eLava rock or lava stone, 1 in. or larger at the base, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eBurner pan, enclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e80 x 6-3\/4 in. Pro Series brass H burner, natural gas (10635)\u003c\/li\u003e\n\u003cli\u003e3\/8 in. x 2 in. stainless nipple (10858) and 1\/2 in. flare to 3\/8 in. FIP fitting (46-86)\u003c\/li\u003e\n\u003cli\u003eBrass burner supports with screws, nuts and washers (10850)\u003c\/li\u003e\n\u003cli\u003eManual key valve (BVL2S) with chrome flange cover (CVR-BVL2CP) and 12 in. chrome key (KEY-PC-12)\u003c\/li\u003e\n\u003cli\u003e46 in. stainless flex gas line (T200-9898-46) and 1\/2 in. flare to 1\/2 in. MIP fitting (U1-8D-S)\u003c\/li\u003e\n\u003cli\u003eFiregear Pro H-Burners and Kits installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eStainless burner pan or disc, at least 80 x 10 in. inside and 2-1\/2 to 3 in. deep, with 1\/4 in. drain holes; Firegear lists its 84 x 16 in. linear flat pan 78053 for this burner (ask us)\u003c\/li\u003e\n\u003cli\u003eA non-combustible linear enclosure, with a 1-1\/4 in. hole for the key valve\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. on opposite sides, for example two 6 x 12 in. vents per side\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock or lava stone, 1 in. or larger at the base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch the fire pit. Do not set it directly on grass, dirt or rocks, keep it level, and build in drainage. Do not fill the enclosure cavity with gravel, rock or sand.\u003c\/li\u003e\n\u003cli\u003eBurner pan: Firegear recommends a 16 gauge stainless pan with 1\/4 in. drain holes and a center hole of at least 7\/8 in. Fit the nipple to the burner with gas-rated thread sealant, fit the brass supports on the legs about 2 in. from each end, mark and drill 1\/4 in. holes in the pan and fasten the supports with the screws, nuts and washers (5\/32 in. Allen wrench). Flared fittings need no sealant.\u003c\/li\u003e\n\u003cli\u003eKey valve: mount it through a 1-1\/4 in. round hole in the enclosure wall; a 1-1\/4 x 2 in. black iron nipple can be used as a spacer. Connect the 46 in. flex line between the valve and the burner fitting without kinking it.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on opposite sides of the enclosure, for example three 2 x 3 in. slots, two 1 x 9 in. slots or two 6 x 12 in. vents per side. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a ceiling and 18 in. to a floor; the manual's diagram shows a 24 in. maximum overhang.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior wall, with a 1\/2 in. male flare fitting for the flex line. Size the supply pipe to NFPA 54 or local code, adding about 5 ft of equivalent length for each fitting; Firegear's charts are for reference only, so at 250,000 Btu\/hr have a licensed plumber or gas fitter size the line. Isolate the appliance for pressure tests at or below 1\/2 psi (3.5 kPa) and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use lava rock or lava stone at least 1 in. across as the base, never stone or river rock. Place it loosely by hand, not poured from the bag or packed tight, cover the burner completely so it is not visible but no more than about 1 in. above it, and never block the injectors. Avoid materials that absorb moisture and release it slowly.\u003c\/li\u003e\n\u003cli\u003eLighting: insert the key and seat it, hold a lit long match or butane lighter near the end of the burner, then slowly turn the key counter-clockwise to ON. If the burner does not light within 10 seconds, turn the key clockwise to off, remove excess media, wait 5 minutes and try again. To shut down, turn the key clockwise until it stops and fit the cover once the unit has cooled.\u003c\/li\u003e\n\u003cli\u003eWeather: after heavy rain let the fire pit dry out before use. In wet conditions media can crack or pop; watch it from a distance for at least 30 minutes after lighting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the fire pit before first use and at least once a year. Clean the injectors with compressed air, wearing eye protection, and replace an injector if debris or nests will not clear. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Never leave it unattended, use it for cooking or burn solid fuels in it, and do not use it if it has been under water until a technician has inspected it. Do not store it indoors unless it is disconnected from the gas supply.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component; its Pro H-Burner instructions give no term in years, so ask us to confirm the term for the burner and key valve before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support. Not covered: accident, misuse, improper installation or maintenance, severe weather, chemical exposure, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification voids all warranties, and installation without proper ventilation voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/4-Burners-Burner-Kits\/Burners-and-Burner-Kits_Pro_H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Outdoor Fire Pit Pro H-Burners and Kits, installation and operating instructions, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/burners-and-kits\/h-pro-burners\" target=\"_blank\" rel=\"noopener\"\u003eFiregear H Pro Burners product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (chromium). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634949619991,"sku":"FG-PSBR-H80-NGK","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-N is a complete linear fire pit burner system for natural gas: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 80,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003eLOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80,000 Btu\/hr on natural gas:\u003c\/strong\u003e the smallest of Firegear's flat H TPSI systems, sized for a 30-inch linear fire pit or fire table; the 36-inch version is rated 95,000 Btu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 20 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., 20 individual injectors (natural gas); burner part FG-PSBR-H24-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e80,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series natural gas H burner (FG-PSBR-H24-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 80,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959417623,"sku":"LOF-3010PS246TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-lof-3010ps246tpsi-n-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-P is a complete linear fire pit burner system for propane: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 110,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003eLOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e110,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 30-inch linear fire pit or fire table, with more output than the 80,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H24-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e110,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series propane H burner (FG-PSBR-H24-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959450391,"sku":"LOF-3010PS246TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-lof-3010ps246tpsi-p-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-N is a complete linear fire pit burner system for natural gas: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 95,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003eLOF-3610PS306TPSI-P\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003e30 x 10-inch LOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e95,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (80,000 Btu) and 48-inch (120,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 24 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., 24 individual injectors (natural gas); burner part FG-PSBR-H30-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e95,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series natural gas H burner (FG-PSBR-H30-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 95,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959515927,"sku":"LOF-3610PS306TPSI-N","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-lof-3610ps306tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-P is a complete linear fire pit burner system for propane: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 115,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003eLOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003e30 x 10-inch propane LOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e115,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (110,000 Btu) and 48-inch (150,000 Btu) propane flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H30-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e115,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series propane H burner (FG-PSBR-H30-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959581463,"sku":"LOF-3610PS306TPSI-P","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-lof-3610ps306tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-N is a complete linear fire pit burner system for natural gas: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 120,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003eLOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003e60 x 10-inch LOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e120,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, between Firegear's 36-inch (95,000 Btu) and 60-inch (160,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 32 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., 32 individual injectors (natural gas); burner part FG-PSBR-H40-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e120,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series natural gas H burner (FG-PSBR-H40-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959614231,"sku":"LOF-4810PS406TPSI-N","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-lof-4810ps406tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-P is a complete linear fire pit burner system for propane: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 150,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003eLOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003e60 x 10-inch propane LOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, with more output than the 120,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H40-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e150,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series propane H burner (FG-PSBR-H40-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959646999,"sku":"LOF-4810PS406TPSI-P","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-lof-4810ps406tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-N is a complete linear fire pit burner system for natural gas: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 160,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors (40 on this natural gas model) instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003eLOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear does not offer conversion kits for Pro Series systems. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160,000 Btu\/hr on natural gas:\u003c\/strong\u003e the highest output of Firegear's 10-inch-wide Pro Series flat H systems, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 40 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete gas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, 40 individual injectors (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e160,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted (propane model LOF-6010PS506TPSI-P, 175,000 Btu\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series natural gas H burner\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for runs over 20 ft on units above 100,000 Btu; its product guide chart shows 3\/4 in. pipe at its 160,000 Btu limit on a 20 ft run, so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959712535,"sku":"LOF-6010PS506TPSI-N","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-lof-6010ps506tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-P is a complete linear fire pit burner system for propane: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003eLOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the highest rating in Firegear's Pro Series flat H TPSI model table, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in. (pan 78127)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, multiple individual brass injectors (propane); burner part FG-PSBR-H50-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series propane H burner (FG-PSBR-H50-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959745303,"sku":"LOF-6010PS506TPSI-P","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-lof-6010ps506tpsi-p-burner-and-gas.jpg?v=1794342538"}],"url":"https:\/\/mnkgrills.com\/collections\/firegear-linear-fire-pit-burners.oembed","provider":"M\u0026K Grills","version":"1.0","type":"link"}