{"title":"Firegear Round Fire Pit Burners","description":"\u003cdiv data-mnk-col-layout\u003e\u003cp\u003eFiregear round fire pit burner systems pair a pan with a Pro Series brass spur burner and TPSI safety ignition. Choose a drop-in pan from 19 to 33 inches or a flat pan from 26 to 34 inches, in natural gas or propane, to fit a round fire bowl or masonry pit.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"mnk-col-guide\"\u003e\n\u003ch2 id=\"round-sizes\"\u003eFiregear round burner sizes\u003c\/h2\u003e\n\u003cp\u003eEach size is sold in a natural gas (-N) and a propane (-P) version. Pan size, pan type and spur length come from the Firegear model numbers.\u003c\/p\u003e\n\u003cdiv class=\"mnk-table-wrap\"\u003e\n\u003ctable class=\"mnk-compare\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003ePan\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePan type\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBrass spur\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIgnition\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eNatural gas\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePropane\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e19-inch\u003c\/th\u003e\n\u003ctd\u003eDrop-in\u003c\/td\u003e\n\u003ctd\u003e14-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003eFPB-19RPSBR14TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003eFPB-19RPSBR14TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e25-inch\u003c\/th\u003e\n\u003ctd\u003eDrop-in\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003eFPB-25RPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003eFPB-25RPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e26-inch\u003c\/th\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003eFPB-26DPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003eFPB-26DPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e29-inch\u003c\/th\u003e\n\u003ctd\u003eDrop-in\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003eFPB-29RPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003eFPB-29RPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e29-inch\u003c\/th\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003eFPB-29DPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003eFPB-29DPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e33-inch\u003c\/th\u003e\n\u003ctd\u003eDrop-in\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003eFPB-33RPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003eFPB-33RPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e34-inch\u003c\/th\u003e\n\u003ctd\u003eFlat\u003c\/td\u003e\n\u003ctd\u003e21-inch\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003eFPB-34DPSBR21TPSI-N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003eFPB-34DPSBR21TPSI-P\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"choosing-round\"\u003eChoosing a round Firegear burner\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure the opening:\u003c\/strong\u003e pick the largest pan that fits inside your fire bowl or ring. The cut-out and fit for each pan are in its Firegear manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in or flat:\u003c\/strong\u003e the two pan types install differently. If you are unsure which suits your build, send us photos and we will confirm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e natural gas and propane are separate models; order the one that matches your line or tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeed square instead?\u003c\/strong\u003e See \u003ca href=\"\/collections\/firegear-square-fire-pit-burners\"\u003eFiregear square burners\u003c\/a\u003e, or \u003ca href=\"\/collections\/firegear-linear-fire-pit-burners\"\u003elinear burners\u003c\/a\u003e for long tables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGo back to \u003ca href=\"\/collections\/firegear\"\u003eall Firegear products\u003c\/a\u003e, or compare \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components from every brand\u003c\/a\u003e. Not sure which size fits your fire pit? Send us your measurements and photos and we will help.\u003c\/p\u003e\n\u003ch2 id=\"faq\"\u003eFiregear round burner FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat size round burner do I need?\u003c\/summary\u003e\u003cp\u003eMeasure the inside diameter of your fire pit opening and choose the pan that fits it. Firegear round systems we carry come in 19, 25, 26, 29, 33 and 34-inch pans. Confirm the cut-out against the Firegear manual, or send us your measurements.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow does Firegear TPSI ignition work?\u003c\/summary\u003e\u003cp\u003eTPSI stands for Thermocouple Piloted Safety Ignition. Firegear says the thermocouple-piloted safety valve turns the gas off if the flame is lost, and a battery spark igniter is included. You hold the igniter button, press and turn the knob to pilot, keep the knob pressed 30 to 60 seconds, then turn it to ON once the pilot is lit.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I convert a Firegear burner from propane to natural gas?\u003c\/summary\u003e\u003cp\u003eOrder the gas type you have, because each Firegear system on this page is sold as a separate natural gas or propane model. Firegear sells propane conversion kits matched to burner BTU, but whether your model can be converted, and who must do it, is set by its manual. Confirm with us before ordering.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat clearances and venting does a Firegear burner need?\u003c\/summary\u003e\u003cp\u003eClearances to combustibles, enclosure ventilation and fire media depth are set in the Firegear installation and operating manual for each burner system. We could not confirm those figures for this page, so confirm with us before you build: we will send the Firegear manual for your exact model, and the manual's requirements govern the install.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty do Firegear Pro Series burners have?\u003c\/summary\u003e\u003cp\u003eFiregear states that its Pro Series burners carry a limited lifetime warranty on parts and components. Terms and exclusions are in Firegear's warranty document; confirm with us for the coverage on your model.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-N is a complete round fire pit burner system for natural gas: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003eFPB-19RPSBR14TPSI-P\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-N\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on natural gas:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (natural gas); burner part FG-PSBR-BS14-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series natural gas Spur burner (FG-PSBR-BS14-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951520535,"sku":"FPB-19RPSBR14TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fpb-19rpsbr14tpsi-n-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Propane Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-P is a complete round fire pit burner system for propane: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003eFPB-19RPSBR14TPSI-N\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-P\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on propane:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (propane); burner part FG-PSBR-BS14-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series propane Spur burner (FG-PSBR-BS14-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951618839,"sku":"FPB-19RPSBR14TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-fpb-19rpsbr14tpsi-p-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003eFPB-25RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-N\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952044823,"sku":"FPB-25RPSBR21TPSI-N","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fpb-25rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342504"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003eFPB-25RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-P\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952175895,"sku":"FPB-25RPSBR21TPSI-P","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-fpb-25rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n","title":"Firegear Pro Series 26-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003eFPB-26DPSBR21TPSI-P\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch FPB-29DPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003e34-inch FPB-34DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952372503,"sku":"FPB-26DPSBR21TPSI-N","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-fpb-26dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p","title":"Firegear Pro Series 26-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003eFPB-26DPSBR21TPSI-N\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch FPB-29DPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003e34-inch FPB-34DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952438039,"sku":"FPB-26DPSBR21TPSI-P","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-fpb-26dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003eFPB-29DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954076439,"sku":"FPB-29DPSBR21TPSI-N","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-fpb-29dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003eFPB-29DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954240279,"sku":"FPB-29DPSBR21TPSI-P","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-fpb-29dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003eFPB-29RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954305815,"sku":"FPB-29RPSBR21TPSI-N","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fpb-29rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003eFPB-29RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954404119,"sku":"FPB-29RPSBR21TPSI-P","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-fpb-29rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003eFPB-33RPSBR21TPSI-P\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955026711,"sku":"FPB-33RPSBR21TPSI-N","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fpb-33rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003eFPB-33RPSBR21TPSI-N\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955125015,"sku":"FPB-33RPSBR21TPSI-P","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-fpb-33rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n","title":"Firegear Pro Series 34-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003eFPB-34DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955288855,"sku":"FPB-34DPSBR21TPSI-N","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-fpb-34dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p","title":"Firegear Pro Series 34-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003eFPB-34DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955354391,"sku":"FPB-34DPSBR21TPSI-P","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-fpb-34dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342537"}],"url":"https:\/\/mnkgrills.com\/collections\/firegear-round-fire-pit-burners.oembed","provider":"M\u0026K Grills","version":"1.0","type":"link"}