{"title":"Firegear","description":"\u003cdiv data-mnk-col-layout\u003e\u003cp\u003eFiregear makes gas fire pit components for custom outdoor fire features: Pro Series brass burner systems in round, square and linear shapes, All Weather electronic ignition, Ironwood steel log sets and ready-to-finish enclosures. Every Firegear burner we carry is sold as a separate natural gas or propane model, so start with your gas supply.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"mnk-col-guide\"\u003e\n\u003ch2 id=\"firegear-product-lines\"\u003eFiregear product lines compared\u003c\/h2\u003e\n\u003cp\u003eFiregear says its Pro Series burners are manufactured in Huntington Beach, California, use brass burners with an injector-style orifice, and are offered with match throw, safety (TPSI) or All Weather System ignition. The lines we carry are below; sizes come from the Firegear model numbers.\u003c\/p\u003e\n\u003cdiv class=\"mnk-table-wrap\"\u003e\n\u003ctable class=\"mnk-compare\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eLine\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eWhat it is\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSizes we carry\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eIgnition\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eShop\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRound burner systems\u003c\/th\u003e\n\u003ctd\u003ePan with brass spur burner\u003c\/td\u003e\n\u003ctd\u003e19 to 34-inch drop-in and flat pans\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-round-fire-pit-burners\"\u003eRound burners\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSquare burner systems\u003c\/th\u003e\n\u003ctd\u003ePan with brass spur burner\u003c\/td\u003e\n\u003ctd\u003e20 to 34-inch drop-in and flat pans\u003c\/td\u003e\n\u003ctd\u003eTPSI\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-square-fire-pit-burners\"\u003eSquare burners\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burners\u003c\/th\u003e\n\u003ctd\u003eFlat-pan systems and H-burner kit\u003c\/td\u003e\n\u003ctd\u003e30 to 60-inch pans; 80-inch H-burner\u003c\/td\u003e\n\u003ctd\u003eTPSI on pan systems\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-linear-fire-pit-burners\"\u003eLinear burners\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAll Weather System (AWS)\u003c\/th\u003e\n\u003ctd\u003eElectronic ignition and 30VDC valve systems\u003c\/td\u003e\n\u003ctd\u003eSingle-feature kit; 290K and 715K BTU valve systems\u003c\/td\u003e\n\u003ctd\u003eAWS\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-fire-pit-ignition-systems\"\u003eAWS ignition\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReady-to-finish enclosures\u003c\/th\u003e\n\u003ctd\u003eFire pit base you finish yourself\u003c\/td\u003e\n\u003ctd\u003e42 to 108 inches, round, square or linear\u003c\/td\u003e\n\u003ctd\u003eAdd a burner\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-fire-pit-enclosures\"\u003eRTF enclosures\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIronwood log sets\u003c\/th\u003e\n\u003ctd\u003eSteel log sets\u003c\/td\u003e\n\u003ctd\u003e11-piece, large, 14-piece XL\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/firegear-fire-pit-log-sets\"\u003eLog sets\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 id=\"shop-firegear-by-category\"\u003eShop Firegear by category\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/firegear-fire-pit-burners\"\u003eFiregear fire pit burners\u003c\/a\u003e: every Pro Series burner system and kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/firegear-fire-pit-enclosures\"\u003eFiregear ready-to-finish enclosures\u003c\/a\u003e for a new fire pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/firegear-fire-pit-ignition-systems\"\u003eFiregear All Weather ignition systems\u003c\/a\u003e for pool-side and multi-feature projects.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/firegear-fire-pit-log-sets\"\u003eFiregear Ironwood steel log sets\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eFiregear Lume fire pit surround, a wood-burning metal smokeless fire pit inside a GFRC enclosure, in \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar\"\u003eArctic White\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch\"\u003eChocolate\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra\"\u003eRaven\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl\"\u003eSlate\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"how-to-build-a-firegear-fire-pit\"\u003eHow to plan a Firegear fire pit\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e use your own masonry pit or a Firegear ready-to-finish enclosure, then measure the opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner:\u003c\/strong\u003e pick the round, square or linear system whose pan fits the opening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas:\u003c\/strong\u003e order natural gas or propane to match your supply; they are separate models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnition:\u003c\/strong\u003e the burner systems we carry use TPSI. For fire features near a pool or spa, or several features on one system, Firegear specifies its All Weather System.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish:\u003c\/strong\u003e add Ironwood steel logs or fire media and follow the Firegear manual for your burner.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComparing brands? See all \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or \u003ca href=\"\/collections\/fire-pits-and-tables\"\u003efire pits and tables\u003c\/a\u003e. Send us your measurements and photos and we will help you size the burner, enclosure and ignition. Can't find a Firegear part? Contact us and we will track it down.\u003c\/p\u003e\n\u003ch2 id=\"faq\"\u003eFiregear FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat warranty do Firegear Pro Series burners have?\u003c\/summary\u003e\u003cp\u003eFiregear states that its Pro Series burners carry a limited lifetime warranty on parts and components. Terms and exclusions are in Firegear's warranty document; confirm with us for the coverage on your model.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhere are Firegear burners made?\u003c\/summary\u003e\u003cp\u003eFiregear says its Pro Series burners are manufactured in Huntington Beach, California.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow does Firegear TPSI ignition work?\u003c\/summary\u003e\u003cp\u003eTPSI stands for Thermocouple Piloted Safety Ignition. Firegear says the thermocouple-piloted safety valve turns the gas off if the flame is lost, and a battery spark igniter is included. You hold the igniter button, press and turn the knob to pilot, keep the knob pressed 30 to 60 seconds, then turn it to ON once the pilot is lit.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhich Firegear ignition do I need near a pool?\u003c\/summary\u003e\u003cp\u003eFiregear says fire features within 5 feet of a pool or spa use its multiple-feature All Weather System, and that the single-feature AWS can only be installed more than 10 feet from a pool or spa. Confirm your layout with us and follow the AWS manual.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I convert a Firegear burner from propane to natural gas?\u003c\/summary\u003e\u003cp\u003eOrder the gas type you have, because each Firegear system on this page is sold as a separate natural gas or propane model. Firegear sells propane conversion kits matched to burner BTU, but whether your model can be converted, and who must do it, is set by its manual. Confirm with us before ordering.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat clearances and venting does a Firegear burner need?\u003c\/summary\u003e\u003cp\u003eClearances to combustibles, enclosure ventilation and fire media depth are set in the Firegear installation and operating manual for each burner system. We could not confirm those figures for this page, so confirm with us before you build: we will send the Firegear manual for your exact model, and the manual's requirements govern the install.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eIs the Firegear Lume gas or wood burning?\u003c\/summary\u003e\u003cp\u003eFiregear describes the Lume surround as a wood-burning fire feature with a metal smoke-less fire pit inside a GFRC enclosure.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n","title":"Firegear Natural Gas All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Single Fire Feature ignition kit for natural gas, model FG-AWS30VDC-GOEK-N: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in one custom-built gas fire pit or fire feature. It ships with its own GOE-30VDC power supply, which plugs into a 120VAC GFI outlet and converts it to 30VDC for the valve, so a single feature needs no separate power supply. Firegear's product guide notes that all of the kit's components can be housed underneath the burner.\u003c\/p\u003e\n\u003cp\u003eThe system is rated for up to 290,000 Btu\/hr at the burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. You turn it on and off with the weatherproof rocker switch on the faceplate, or add an optional remote, wall switch, timer or emergency stop.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this kit is for \u003cstrong\u003eone\u003c\/strong\u003e fire feature only, installed at least 10 feet from a pool or spa. For two to four features, or any feature within 5 feet of a pool or spa, Firegear specifies the \u003ca href=\"\/products\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n\"\u003eAWS multiple fire feature kit (FG-AWS30VDC-K-N)\u003c\/a\u003e with the FG-AWS-PS-30V320 pool-certified power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The propane version is FG-AWS30VDC-GOEK-P.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply included:\u003c\/strong\u003e the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-GOEK-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSingle fire feature ignition kit (power supply included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOne fire feature, installed 10 ft or more from a pool or spa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; Firegear notes only natural gas models can be converted to propane, by changing the pilot orifice (FG-AWS-PBO-P) and the main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eGOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eGOE-30VDC power supply for one fire feature\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-NG orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003ePropane conversion: pilot orifice kit FG-AWS-PBO-P plus a propane main burner orifice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Do not install the kit without a main burner orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-single-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Single Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947719447,"sku":"FG-AWS30VDC-GOEK-N","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-natural-gas-all-weather-ignition-system-for-single-fg-aws30vdc-goek-n-kit-components.jpg?v=1794342503"},{"product_id":"firegear-propane-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-p","title":"Firegear Propane All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Single Fire Feature ignition kit for propane, model FG-AWS30VDC-GOEK-P: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in one custom-built gas fire pit or fire feature. It ships with its own GOE-30VDC power supply, which plugs into a 120VAC GFI outlet and converts it to 30VDC for the valve, so a single feature needs no separate power supply. Firegear's product guide notes that all of the kit's components can be housed underneath the burner.\u003c\/p\u003e\n\u003cp\u003eThe system is rated for up to 290,000 Btu\/hr at the burner, and Firegear's propane orifice table runs from 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12). A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. You turn it on and off with the weatherproof rocker switch on the faceplate, or add an optional remote, wall switch, timer or emergency stop.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this kit is for \u003cstrong\u003eone\u003c\/strong\u003e fire feature only, installed at least 10 feet from a pool or spa. For two to four features, or any feature within 5 feet of a pool or spa, Firegear specifies the \u003ca href=\"\/products\/firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p\"\u003eAWS multiple fire feature kit for propane (FG-AWS30VDC-K-P)\u003c\/a\u003e with the FG-AWS-PS-30V320 pool-certified power supply. Propane needs its own planning: Firegear requires ventilation and drainage at the bottom of the feature, an LP tank of at least 100 lb kept outside the enclosure, and a 3-inch nipple in the burner ahead of the propane orifice. Order the fuel you will use: Firegear states that only natural gas models can be converted to propane. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The natural gas version is the \u003ca href=\"\/products\/firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n\"\u003eFG-AWS30VDC-GOEK-N\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply included:\u003c\/strong\u003e the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet up for propane:\u003c\/strong\u003e propane pilot orifice (FG-PBO-LP) on the pilot, with Firegear's LP orifice table (OAS-LP41 to OAS-LP12) for sizing the main burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-GOEK-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSingle fire feature ignition kit (power supply included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOne fire feature, installed 10 ft or more from a pool or spa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; propane orifice table 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane (LP). Models are ordered as natural gas or propane; Firegear states only natural gas models can be converted to propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi), low-pressure LP after regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLP supply\u003c\/th\u003e\n\u003ctd\u003eTank of 100 lb capacity or more, located outside the fire pit enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMain burner orifice\u003c\/th\u003e\n\u003ctd\u003eNot included; LP orifices have vent holes at the base, and propane installs need a 3\" nipple in the burner before the orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with LP pilot orifice (FG-PBO-LP) and thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eGOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, LP tank and regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003ePilot burner assembly (FG-PBA) set up for propane, with heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eGOE-30VDC power supply for one fire feature\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA fire pit pan and burner, and the propane main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side); for propane, vents go at the bottom of the feature\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003eReplacement LP pilot orifice FG-PBO-LP\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003ePropane ventilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure, at the bottom of the feature. Propane is heavier than air and settles, so Firegear requires drainage and ventilation at the bottom and a vent or drain line so gas cannot collect. Firegear states that failure to provide proper ventilation voids the warranty.\u003c\/li\u003e\n\u003cli\u003eLP tank: use a tank of at least 100 lb capacity, keep every LP tank outside the enclosure, and do not store an LP cylinder that is not connected near this or any other appliance.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner ports facing up, the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's LP pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi. Install a 3\" nipple in the burner before the LP orifice, and never run the kit without a main burner orifice. If the wrong pilot orifice is fitted, the pilot will not light.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-single-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Single Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947752215,"sku":"FG-AWS30VDC-GOEK-P","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-propane-all-weather-ignition-system-for-single-fg-aws30vdc-goek-p-kit-components-chart.jpg?v=1794342543"},{"product_id":"firegear-715k-btu-high-capacity-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-hc-k-n","title":"Firegear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System - FG-AWS30VDC-HC-K-N","description":"\u003ch2\u003eFiregear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System\u003c\/h2\u003e\n\u003cp\u003eA gas valve component for gas fire pits and fire features that controls the gas flow to the burner.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eThe Firegear 715K BTU High Capacity Natural Gas 30VDC All Weather Valve System controls the gas flow to the burner.\u003c\/p\u003e\n\u003cp\u003eHandles up to 715,000 BTU. 3\/4\" FIP gas inlet. Confirm compatibility with your burner system before ordering.\u003c\/p\u003e\n\u003cp\u003eGas and electrical connections should be made by a licensed professional following local codes.\u003c\/p\u003e\n\u003cp\u003eNot sure it works with your system? Send us your burner model and our team will confirm compatibility. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve component for gas fire features\u003c\/li\u003e\n\u003cli\u003eWeatherproof housing\u003c\/li\u003e\n\u003cli\u003e715,000 BTU capacity\u003c\/li\u003e\n\u003cli\u003eNatural gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-HC-K-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eGas valve component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e715,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight (as listed by distributor)\u003c\/th\u003e\n\u003ctd\u003e12 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947784983,"sku":"FG-AWS30VDC-HC-K-N","price":4489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-715k-btu-high-capacity-natural-gas-30vdc-all-fg-aws30vdc-hc-k-n-kit-components-chart.jpg?v=1794342490"},{"product_id":"firegear-715k-btu-high-capacity-propane-30vdc-all-weather-valve-system-fg-aws30vdc-hc-k-p","title":"Firegear 715K BTU High Capacity Propane 30VDC All Weather Valve System - FG-AWS30VDC-HC-K-P","description":"\u003ch2\u003eFiregear 715K BTU High Capacity Propane 30VDC All Weather Valve System\u003c\/h2\u003e\n\u003cp\u003eA gas valve component for gas fire pits and fire features that controls the gas flow to the burner.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eThe Firegear 715K BTU High Capacity Propane 30VDC All Weather Valve System controls the gas flow to the burner.\u003c\/p\u003e\n\u003cp\u003eHandles up to 715,000 BTU. 3\/4\" FIP gas inlet. Confirm compatibility with your burner system before ordering.\u003c\/p\u003e\n\u003cp\u003eGas and electrical connections should be made by a licensed professional following local codes.\u003c\/p\u003e\n\u003cp\u003eNot sure it works with your system? Send us your burner model and our team will confirm compatibility. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve component for gas fire features\u003c\/li\u003e\n\u003cli\u003eWeatherproof housing\u003c\/li\u003e\n\u003cli\u003e715,000 BTU capacity\u003c\/li\u003e\n\u003cli\u003ePropane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-HC-K-P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eGas valve component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCapacity\u003c\/th\u003e\n\u003ctd\u003e715,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight (as listed by distributor)\u003c\/th\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634947948823,"sku":"FG-AWS30VDC-HC-K-P","price":4489.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-715k-btu-high-capacity-propane-30vdc-all-weather-fg-aws30vdc-hc-k-p-kit-components.jpg?v=1794342490"},{"product_id":"firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n","title":"Firegear 290K BTU Natural Gas 30VDC All Weather Valve System - FG-AWS30VDC-K-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Multiple Fire Feature valve kit for natural gas, model FG-AWS30VDC-K-N: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in a custom-built gas fire pit or fire feature. It is the kit Firegear specifies when you run one to four fire features from one power supply, and for any fire feature within 5 feet of a pool or spa. One kit goes in each fire feature.\u003c\/p\u003e\n\u003cp\u003eEach kit is rated for up to 290,000 Btu\/hr at its burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu; one valve can serve a linear burner from 24 inches up to 14 feet long. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. Turn it on with the faceplate rocker switch, or with an optional remote, wall switch, timer or emergency stop; on a switched supply the feature turns on when power is applied and off when it is removed.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: the power supply is \u003cstrong\u003enot included\u003c\/strong\u003e. Each FG-AWS-PS-30V320 30VDC pool-certified power supply runs up to four fire features up to 500 feet away. For a single feature at least 10 feet from a pool or spa, the \u003ca href=\"\/products\/firegear-natural-gas-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-n\"\u003esingle fire feature kit (FG-AWS30VDC-GOEK-N)\u003c\/a\u003e includes its own power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The propane version is FG-AWS30VDC-K-P.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for multiple features and pools:\u003c\/strong\u003e up to four fire features share one FG-AWS-PS-30V320 supply up to 500 feet away, and it is the kit Firegear specifies within 5 feet of a pool or spa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-K-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eMultiple fire feature valve kit (power supply not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003e1 to 4 fire features per power supply, and any feature within 5 ft of a pool or spa; one kit per fire feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; Firegear notes only natural gas models can be converted to propane, by changing the pilot orifice (FG-AWS-PBO-P) and the main burner orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eNot included: FG-AWS-PS-30V320 (30VDC, 320 W pool-certified; output +30 V, 10.7 A), up to 4 features up to 500 ft away\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eFG-AWS-PS-30V320 30VDC pool-certified power supply (required; one per four fire features); ask us to order\u003c\/li\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-NG orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003cli\u003ePropane conversion: pilot orifice kit FG-AWS-PBO-P plus a propane main burner orifice\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Do not install the kit without a main burner orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. Features within 5 ft of a pool or spa require the FG-AWS-PS-30V320 low-voltage supply, set at least 10 ft from the water, with the junction box and gas pipe bonded with 8 AWG or larger copper. Keep polarity the same on every daisy-chained feature (four maximum).\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-multiple-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Multiple Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634948014359,"sku":"FG-AWS30VDC-K-N","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n-kit-components.jpg?v=1794342478"},{"product_id":"firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p","title":"Firegear 290K BTU Propane 30VDC All Weather Valve System - FG-AWS30VDC-K-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThis is Firegear's AWS (All Weather System) Multiple Fire Feature valve kit for propane (LP), model FG-AWS30VDC-K-P: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in a custom-built gas fire pit or fire feature. It is the kit Firegear specifies when you run one to four fire features from one power supply, and for any fire feature within 5 feet of a pool or spa. One kit goes in each fire feature.\u003c\/p\u003e\n\u003cp\u003eEach kit is rated for up to 290,000 Btu\/hr at its burner, and Firegear's orifice table runs from 75,000 to 250,000 Btu; one valve can serve a linear burner from 24 inches up to 14 feet long. A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. Turn it on with the faceplate rocker switch, or with an optional remote, wall switch, timer or emergency stop; on a switched supply the feature turns on when power is applied and off when it is removed.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: the power supply is \u003cstrong\u003enot included\u003c\/strong\u003e. Each FG-AWS-PS-30V320 30VDC pool-certified power supply runs up to four fire features up to 500 feet away. For a single feature at least 10 feet from a pool or spa, the \u003ca href=\"\/products\/firegear-propane-all-weather-ignition-system-for-single-fire-feature-fg-aws30vdc-goek-p\"\u003esingle fire feature kit (FG-AWS30VDC-GOEK-P)\u003c\/a\u003e includes its own power supply. The pan, burner and main burner orifice are not included; see our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e. The natural gas version is FG-AWS30VDC-K-N.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e30VDC all-weather electronic ignition:\u003c\/strong\u003e low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt for multiple features and pools:\u003c\/strong\u003e up to four fire features share one FG-AWS-PS-30V320 supply up to 500 feet away, and it is the kit Firegear specifies within 5 feet of a pool or spa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUp to 290,000 Btu\/hr per fire feature:\u003c\/strong\u003e sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic relight and lockout:\u003c\/strong\u003e the controller makes three relight attempts, then locks out until it is switched off and on again.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with your choice of switch:\u003c\/strong\u003e faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertified for the USA and Canada:\u003c\/strong\u003e tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eAWS (All Weather Electronic Ignition System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-AWS30VDC-K-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eMultiple fire feature valve kit (power supply not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003e1 to 4 fire features per power supply, and any feature within 5 ft of a pool or spa; one kit per fire feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum input\u003c\/th\u003e\n\u003ctd\u003e290,000 Btu\/hr per fire feature; orifice table 75,000 to 250,000 Btu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLinear burner length\u003c\/th\u003e\n\u003ctd\u003e24 in. to 14 ft per valve (longer systems: custom quote)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane (LP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, natural gas\u003c\/th\u003e\n\u003ctd\u003eMin 3.5\" WC (1\/8 psi), normal 7.0\" WC (1\/4 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure, propane\u003c\/th\u003e\n\u003ctd\u003eMin 8.0\" WC (1\/4 psi), normal 11.0\" WC (3\/8 psi), max 14.0\" WC (1\/2 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2\" flare x 1\/2\" MIP fitting (U1-8D-S) at the valve inlet; a 3\/4\" burner needs a reducer; 46\" flex connector from the valve box to the manual key valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eHot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValve power\u003c\/th\u003e\n\u003ctd\u003e30VDC from the power supply; never connect 120VAC directly to the valve wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003eNot included: FG-AWS-PS-30V320 (30VDC, 320 W pool-certified; output +30 V, 10.7 A), up to 4 features up to 500 ft away\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWiring\u003c\/th\u003e\n\u003ctd\u003e12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot placement\u003c\/th\u003e\n\u003ctd\u003ePilot assembly within 22\" of the valve box (24\" pilot gas lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eManual key valve\u003c\/th\u003e\n\u003ctd\u003eNeeds a 1-1\/4\" round clearance hole in the non-combustible enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003eListed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eLab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003ePan, burner, main burner orifice, power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30VDC AWS gas valve with ignition control box (FG-ICB)\u003c\/li\u003e\n\u003cli\u003ePropane pilot burner assembly (FG-PBA) and heat shield (FG-HEATSHIELD)\u003c\/li\u003e\n\u003cli\u003ePower wire to the valve (10626)\u003c\/li\u003e\n\u003cli\u003eKey valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)\u003c\/li\u003e\n\u003cli\u003eHardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3\/4\" screws, brass nut, two 8-18 x 1\/2\" screws, 1\/2\" NPT x 1\/2\" flare fitting\u003c\/li\u003e\n\u003cli\u003eFiregear AWS installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eFG-AWS-PS-30V320 30VDC pool-certified power supply (required; one per four fire features); ask us to order\u003c\/li\u003e\n\u003cli\u003eA fire pit pan and burner, and the main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e or the \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn\/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order\u003c\/li\u003e\n\u003cli\u003eEnclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS \/ PAVER-VENT-6LNTS (each gives 18 sq. in. per side)\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock (1 to 2 in.) or fire glass (1\/2 to 3\/4 in.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).\u003c\/li\u003e\n\u003cli\u003eEnclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1\/4\" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure; Firegear states that failure to provide proper ventilation voids the warranty. Propane needs ventilation at the bottom (LP is heavier than air); natural gas bowls need ventilation at the top through the disc or pan.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36\" side wall, 96\" ceiling, 18\" floor; 150,000 to 250,000 Btu needs a 120\" ceiling. Pan depth 2-1\/2\" to 3\". Keep the burner at least 3\" inside the pan or bowl and at least 6\" from its edge, and mount the pilot within 22\" of the valve box using the supplied template.\u003c\/li\u003e\n\u003cli\u003eGas: size the supply pipe with Firegear's pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1\/2 psi; buried lines may be tested up to 60 psi. Never place an LP tank inside the enclosure; Firegear's instructions call for a tank of at least 100 lb outside it. Propane installs need a 3\" nipple in the burner before the LP orifice.\u003c\/li\u003e\n\u003cli\u003eElectrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. Features within 5 ft of a pool or spa require the FG-AWS-PS-30V320 low-voltage supply, set at least 10 ft from the water, with the junction box and gas pipe bonded with 8 AWG or larger copper. Keep polarity the same on every daisy-chained feature (four maximum).\u003c\/li\u003e\n\u003cli\u003eMedia: lava rock at least 1 to 2 in. or glass at least 1\/2 to 3\/4 in., no more than 1\" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.\u003c\/li\u003e\n\u003cli\u003eLighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01\/01\/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition_AWS30VDC-K-L.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, AWS a la carte systems (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/aws-ignition-system\/aws-multiple-fire-feature-ignition-system\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS Multiple Fire Feature Ignition System product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634948112663,"sku":"FG-AWS30VDC-K-P","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-290k-btu-propane-30vdc-all-weather-valve-system-fg-aws30vdc-k-p-kit-components-chart.jpg?v=1794342478"},{"product_id":"firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk","title":"Firegear Pro Series 80 x 6.75-Inch Propane H-Burner Kit - FG-PSBR-H80-LPK","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FG-PSBR-H80-LPK is an 80 x 6-3\/4 inch brass H burner kit for propane, rated at 240,000 Btu\/hr, for long linear fire pits and fire tables that you or your builder make. The kit pairs Firegear's Pro Series H burner, which feeds the flame through 64 individual brass injectors instead of a single orifice, with a manual key valve, a 12-inch chrome key and a 46-inch stainless flex line. It is lit by hand: you hold a long match or butane lighter at the burner and open the key valve.\u003c\/p\u003e\n\u003cp\u003eThis is the longest H burner in Firegear's Pro Series range, which runs from 24 to 80 inches. It mounts on brass supports in a stainless pan or disc that you supply, with an inside size of at least 80 x 10 inches and a depth of 2-1\/2 to 3 inches; Firegear lists its 84 x 16 inch linear flat pan (78053) for the 80-inch burner. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk\"\u003eFG-PSBR-H80-NGK\u003c\/a\u003e, rated at 250,000 Btu\/hr. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors, and its Pro Series burners have no conversion kit, so choose the gas type before you order. This kit has no pilot, flame-sensing safety valve or electronic ignition. The burner pan, the enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e240,000 Btu\/hr on propane:\u003c\/strong\u003e the highest-rated burner in Firegear's Pro Series H range, sized for a long linear fire feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e64 brass injectors:\u003c\/strong\u003e the Pro Series H burner spreads its flame across many individual injectors (size #72, 0.025 in. on propane) for a fuller flame along the full 80-inch length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey valve kit:\u003c\/strong\u003e a manual key valve (BVL2S) with a chrome flange cover and a 12-inch chrome key lets you set the flame from the side of the enclosure, with no wiring or batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46-inch stainless flex line in the box:\u003c\/strong\u003e connects the key valve to the burner fitting, so you only bring the supply line to a shut-off valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass supports and hardware:\u003c\/strong\u003e the burner bolts to your stainless pan, so it stays level and centered under the media.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series H burners and kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-PSBR-H80-LPK (propane kit); burner only: FG-PSBR-H80-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear H burner kit with manual key valve (match-lit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e80 x 6-3\/4 in. Pro Series brass H burner; replacement burner part 10808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjectors\u003c\/th\u003e\n\u003ctd\u003e64, size #72 (0.025 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e240,000 Btu\/hr (70.33 kW), rated at 11.0 in. WC at the burner orifice; flex line and pipe sizing can change the actual output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models, no conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 10.5 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eManual: long match or butane lighter at the burner while opening the key valve; no pilot or flame safety device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eManual key valve BVL2S with chrome flange cover CVR-BVL2CP and 12 in. chrome key KEY-PC-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e46 in. stainless flex line (T200-9898-46) to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner pan (not included)\u003c\/th\u003e\n\u003ctd\u003eStainless, 16 gauge recommended; at least 80 x 10 in. inside, 2-1\/2 to 3 in. deep; Firegear lists the 84 x 16 in. linear flat pan 78053 for this burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKey valve mounting\u003c\/th\u003e\n\u003ctd\u003e1-1\/4 in. round hole in the enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation on opposite sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor; the manual's diagram shows a 24 in. maximum overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003eLava rock or lava stone, 1 in. or larger at the base, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eBurner pan, enclosure, manual shut-off valve, vents, fire media, propane tank and regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e80 x 6-3\/4 in. Pro Series brass H burner, propane (10808)\u003c\/li\u003e\n\u003cli\u003e3\/8 in. x 2 in. stainless nipple (10858) and 1\/2 in. flare to 3\/8 in. FIP fitting (46-86)\u003c\/li\u003e\n\u003cli\u003eBrass burner supports with screws, nuts and washers (10850)\u003c\/li\u003e\n\u003cli\u003eManual key valve (BVL2S) with chrome flange cover (CVR-BVL2CP) and 12 in. chrome key (KEY-PC-12)\u003c\/li\u003e\n\u003cli\u003e46 in. stainless flex gas line (T200-9898-46) and 1\/2 in. flare to 1\/2 in. MIP fitting (U1-8D-S)\u003c\/li\u003e\n\u003cli\u003eFiregear Pro H-Burners and Kits installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eStainless burner pan or disc, at least 80 x 10 in. inside and 2-1\/2 to 3 in. deep, with 1\/4 in. drain holes; Firegear lists its 84 x 16 in. linear flat pan 78053 for this burner (ask us)\u003c\/li\u003e\n\u003cli\u003eA non-combustible linear enclosure, with a 1-1\/4 in. hole for the key valve\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. on opposite sides, for example two 6 x 12 in. vents per side\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock or lava stone, 1 in. or larger at the base\u003c\/li\u003e\n\u003cli\u003ePropane supply: tank and regulator, planned with your gas supplier (not included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch the fire pit. Do not set it directly on grass, dirt or rocks, keep it level, and build in drainage. Do not fill the enclosure cavity with gravel, rock or sand.\u003c\/li\u003e\n\u003cli\u003eBurner pan: Firegear recommends a 16 gauge stainless pan with 1\/4 in. drain holes and a center hole of at least 7\/8 in. Fit the nipple to the burner with gas-rated thread sealant, fit the brass supports on the legs about 2 in. from each end, mark and drill 1\/4 in. holes in the pan and fasten the supports with the screws, nuts and washers (5\/32 in. Allen wrench). Flared fittings need no sealant.\u003c\/li\u003e\n\u003cli\u003eKey valve: mount it through a 1-1\/4 in. round hole in the enclosure wall; a 1-1\/4 x 2 in. black iron nipple can be used as a spacer. Connect the 46 in. flex line between the valve and the burner fitting without kinking it.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on opposite sides of the enclosure, for example three 2 x 3 in. slots, two 1 x 9 in. slots or two 6 x 12 in. vents per side. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a ceiling and 18 in. to a floor; the manual's diagram shows a 24 in. maximum overhang.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior wall, with a 1\/2 in. male flare fitting for the flex line. Size the supply pipe to NFPA 54 or local code, adding about 5 ft of equivalent length for each fitting; Firegear's charts are for reference only, so at 240,000 Btu\/hr have a licensed plumber or gas fitter size the line. Isolate the appliance for pressure tests at or below 1\/2 psi (3.5 kPa) and leak-test every connection with soapy water before use. Plan the propane supply and regulator with your gas supplier; the kit does not include a regulator or tank, and Firegear says never to store an LP cylinder that is not connected for use near this or any other appliance.\u003c\/li\u003e\n\u003cli\u003eMedia: use lava rock or lava stone at least 1 in. across as the base, never stone or river rock. Place it loosely by hand, not poured from the bag or packed tight, cover the burner completely so it is not visible but no more than about 1 in. above it, and never block the injectors. Avoid materials that absorb moisture and release it slowly.\u003c\/li\u003e\n\u003cli\u003eLighting: insert the key and seat it, hold a lit long match or butane lighter near the end of the burner, then slowly turn the key counter-clockwise to ON. If the burner does not light within 10 seconds, turn the key clockwise to off, remove excess media, wait 5 minutes and try again. To shut down, turn the key clockwise until it stops and fit the cover once the unit has cooled.\u003c\/li\u003e\n\u003cli\u003eWeather: after heavy rain let the fire pit dry out before use. In wet conditions media can crack or pop; watch it from a distance for at least 30 minutes after lighting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the fire pit before first use and at least once a year. Clean the injectors with compressed air, wearing eye protection, and replace an injector if debris or nests will not clear. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Never leave it unattended, use it for cooking or burn solid fuels in it, and do not use it if it has been under water until a technician has inspected it. Do not store it indoors unless it is disconnected from the gas supply.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component; its Pro H-Burner instructions give no term in years, so ask us to confirm the term for the burner and key valve before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support. Not covered: accident, misuse, improper installation or maintenance, severe weather, chemical exposure, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification voids all warranties, and installation without proper ventilation voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/4-Burners-Burner-Kits\/Burners-and-Burner-Kits_Pro_H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Outdoor Fire Pit Pro H-Burners and Kits, installation and operating instructions, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/burners-and-kits\/h-pro-burners\" target=\"_blank\" rel=\"noopener\"\u003eFiregear H Pro Burners product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (chromium). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634949521687,"sku":"FG-PSBR-H80-LPK","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk-burner-and-gas-fitting.jpg?v=1794342543"},{"product_id":"firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk","title":"Firegear Pro Series 80 x 6.75-Inch Natural Gas H-Burner Kit - FG-PSBR-H80-NGK","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FG-PSBR-H80-NGK is an 80 x 6-3\/4 inch brass H burner kit for natural gas, rated at 250,000 Btu\/hr, for long linear fire pits and fire tables that you or your builder make. The kit pairs Firegear's Pro Series H burner, which feeds the flame through 64 individual brass injectors instead of a single orifice, with a manual key valve, a 12-inch chrome key and a 46-inch stainless flex line. It is lit by hand: you hold a long match or butane lighter at the burner and open the key valve.\u003c\/p\u003e\n\u003cp\u003eThis is the longest H burner in Firegear's Pro Series range, which runs from 24 to 80 inches. It mounts on brass supports in a stainless pan or disc that you supply, with an inside size of at least 80 x 10 inches and a depth of 2-1\/2 to 3 inches; Firegear lists its 84 x 16 inch linear flat pan (78053) for the 80-inch burner. The propane version is \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-propane-h-burner-kit-fg-psbr-h80-lpk\"\u003eFG-PSBR-H80-LPK\u003c\/a\u003e, rated at 240,000 Btu\/hr. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors, and its Pro Series burners have no conversion kit, so choose the gas type before you order. This kit has no pilot, flame-sensing safety valve or electronic ignition. The burner pan, the enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e250,000 Btu\/hr on natural gas:\u003c\/strong\u003e the highest-rated burner in Firegear's Pro Series H range, sized for a long linear fire feature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e64 brass injectors:\u003c\/strong\u003e the Pro Series H burner spreads its flame across many individual injectors (size #68, 0.031 in. on natural gas) for a fuller flame along the full 80-inch length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey valve kit:\u003c\/strong\u003e a manual key valve (BVL2S) with a chrome flange cover and a 12-inch chrome key lets you set the flame from the side of the enclosure, with no wiring or batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e46-inch stainless flex line in the box:\u003c\/strong\u003e connects the key valve to the burner fitting, so you only bring the supply line to a shut-off valve.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass supports and hardware:\u003c\/strong\u003e the burner bolts to your stainless pan, so it stays level and centered under the media.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series H burners and kits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFG-PSBR-H80-NGK (natural gas kit); burner only: FG-PSBR-H80-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear H burner kit with manual key valve (match-lit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e80 x 6-3\/4 in. Pro Series brass H burner; replacement burner part 10635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjectors\u003c\/th\u003e\n\u003ctd\u003e64, size #68 (0.031 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e250,000 Btu\/hr (73.27 kW), rated at 7.0 in. WC at the burner orifice; flex line and pipe sizing can change the actual output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models, no conversion kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 5.0 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eManual: long match or butane lighter at the burner while opening the key valve; no pilot or flame safety device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eManual key valve BVL2S with chrome flange cover CVR-BVL2CP and 12 in. chrome key KEY-PC-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e46 in. stainless flex line (T200-9898-46) to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner pan (not included)\u003c\/th\u003e\n\u003ctd\u003eStainless, 16 gauge recommended; at least 80 x 10 in. inside, 2-1\/2 to 3 in. deep; Firegear lists the 84 x 16 in. linear flat pan 78053 for this burner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eKey valve mounting\u003c\/th\u003e\n\u003ctd\u003e1-1\/4 in. round hole in the enclosure wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation on opposite sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor; the manual's diagram shows a 24 in. maximum overhang\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003eLava rock or lava stone, 1 in. or larger at the base, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eBurner pan, enclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e80 x 6-3\/4 in. Pro Series brass H burner, natural gas (10635)\u003c\/li\u003e\n\u003cli\u003e3\/8 in. x 2 in. stainless nipple (10858) and 1\/2 in. flare to 3\/8 in. FIP fitting (46-86)\u003c\/li\u003e\n\u003cli\u003eBrass burner supports with screws, nuts and washers (10850)\u003c\/li\u003e\n\u003cli\u003eManual key valve (BVL2S) with chrome flange cover (CVR-BVL2CP) and 12 in. chrome key (KEY-PC-12)\u003c\/li\u003e\n\u003cli\u003e46 in. stainless flex gas line (T200-9898-46) and 1\/2 in. flare to 1\/2 in. MIP fitting (U1-8D-S)\u003c\/li\u003e\n\u003cli\u003eFiregear Pro H-Burners and Kits installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eStainless burner pan or disc, at least 80 x 10 in. inside and 2-1\/2 to 3 in. deep, with 1\/4 in. drain holes; Firegear lists its 84 x 16 in. linear flat pan 78053 for this burner (ask us)\u003c\/li\u003e\n\u003cli\u003eA non-combustible linear enclosure, with a 1-1\/4 in. hole for the key valve\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. on opposite sides, for example two 6 x 12 in. vents per side\u003c\/li\u003e\n\u003cli\u003eFire media: lava rock or lava stone, 1 in. or larger at the base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch the fire pit. Do not set it directly on grass, dirt or rocks, keep it level, and build in drainage. Do not fill the enclosure cavity with gravel, rock or sand.\u003c\/li\u003e\n\u003cli\u003eBurner pan: Firegear recommends a 16 gauge stainless pan with 1\/4 in. drain holes and a center hole of at least 7\/8 in. Fit the nipple to the burner with gas-rated thread sealant, fit the brass supports on the legs about 2 in. from each end, mark and drill 1\/4 in. holes in the pan and fasten the supports with the screws, nuts and washers (5\/32 in. Allen wrench). Flared fittings need no sealant.\u003c\/li\u003e\n\u003cli\u003eKey valve: mount it through a 1-1\/4 in. round hole in the enclosure wall; a 1-1\/4 x 2 in. black iron nipple can be used as a spacer. Connect the 46 in. flex line between the valve and the burner fitting without kinking it.\u003c\/li\u003e\n\u003cli\u003eVentilation: provide at least 18 sq. in. of cross ventilation on opposite sides of the enclosure, for example three 2 x 3 in. slots, two 1 x 9 in. slots or two 6 x 12 in. vents per side. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a ceiling and 18 in. to a floor; the manual's diagram shows a 24 in. maximum overhang.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior wall, with a 1\/2 in. male flare fitting for the flex line. Size the supply pipe to NFPA 54 or local code, adding about 5 ft of equivalent length for each fitting; Firegear's charts are for reference only, so at 250,000 Btu\/hr have a licensed plumber or gas fitter size the line. Isolate the appliance for pressure tests at or below 1\/2 psi (3.5 kPa) and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use lava rock or lava stone at least 1 in. across as the base, never stone or river rock. Place it loosely by hand, not poured from the bag or packed tight, cover the burner completely so it is not visible but no more than about 1 in. above it, and never block the injectors. Avoid materials that absorb moisture and release it slowly.\u003c\/li\u003e\n\u003cli\u003eLighting: insert the key and seat it, hold a lit long match or butane lighter near the end of the burner, then slowly turn the key counter-clockwise to ON. If the burner does not light within 10 seconds, turn the key clockwise to off, remove excess media, wait 5 minutes and try again. To shut down, turn the key clockwise until it stops and fit the cover once the unit has cooled.\u003c\/li\u003e\n\u003cli\u003eWeather: after heavy rain let the fire pit dry out before use. In wet conditions media can crack or pop; watch it from a distance for at least 30 minutes after lighting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the fire pit before first use and at least once a year. Clean the injectors with compressed air, wearing eye protection, and replace an injector if debris or nests will not clear. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Never leave it unattended, use it for cooking or burn solid fuels in it, and do not use it if it has been under water until a technician has inspected it. Do not store it indoors unless it is disconnected from the gas supply.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component; its Pro H-Burner instructions give no term in years, so ask us to confirm the term for the burner and key valve before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support. Not covered: accident, misuse, improper installation or maintenance, severe weather, chemical exposure, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification voids all warranties, and installation without proper ventilation voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/4-Burners-Burner-Kits\/Burners-and-Burner-Kits_Pro_H.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Outdoor Fire Pit Pro H-Burners and Kits, installation and operating instructions, Rev. D (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/burners-and-kits\/h-pro-burners\" target=\"_blank\" rel=\"noopener\"\u003eFiregear H Pro Burners product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (chromium). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634949619991,"sku":"FG-PSBR-H80-NGK","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-N is a complete round fire pit burner system for natural gas: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003eFPB-19RPSBR14TPSI-P\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-N\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on natural gas:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (natural gas); burner part FG-PSBR-BS14-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series natural gas Spur burner (FG-PSBR-BS14-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951520535,"sku":"FPB-19RPSBR14TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fpb-19rpsbr14tpsi-n-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p","title":"Firegear Pro Series 19-Inch Round Drop-In Pan Propane Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-19RPSBR14TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-19RPSBR14TPSI-P is a complete round fire pit burner system for propane: a 19-inch round stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003eFPB-19RPSBR14TPSI-N\u003c\/a\u003e; for a square pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p\"\u003e20-inch square drop-in FPB-20SPSBR14TPSI-P\u003c\/a\u003e (also 125,000 Btu), or for a larger round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 19-1\/4 to 20 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on propane:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest round Pro Series drop-in pan, rated the same as the 20-inch square drop-in; the 25-inch and larger pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 19-1\/4 to 20-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-19RPSBR14TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e19 in. round stainless drop-in pan (PAN-SS19R), 19 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e19-1\/4 in. minimum to 20 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (propane); burner part FG-PSBR-BS14-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e19 in. round stainless drop-in pan (PAN-SS19R) with 14 in. Pro Series propane Spur burner (FG-PSBR-BS14-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure with a 19-1\/4 to 20 in. opening (Firegear's ready-to-finish round enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 19-1\/4 to 20 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951618839,"sku":"FPB-19RPSBR14TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-fpb-19rpsbr14tpsi-p-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n","title":"Firegear Pro Series 20-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-20SPSBR14TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-20SPSBR14TPSI-N is a complete square fire pit burner system for natural gas: a 20-inch square stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p\"\u003eFPB-20SPSBR14TPSI-P\u003c\/a\u003e; for a round pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-N\u003c\/a\u003e (also 125,000 Btu), or for a larger square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 20-1\/4 to 21 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on natural gas:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest square Pro Series drop-in pan, rated the same as the 19-inch round drop-in; the 26-inch and larger square pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 20-1\/4 to 21-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-20SPSBR14TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e20 in. square stainless drop-in pan (PAN-SS20S), 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e20-1\/4 in. minimum to 21 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (natural gas); burner part FG-PSBR-BS14-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e20 in. square stainless drop-in pan (PAN-SS20S) with 14 in. Pro Series natural gas Spur burner (FG-PSBR-BS14-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with a 20-1\/4 to 21 in. opening (Firegear's ready-to-finish square enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 20-1\/4 to 21 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951717143,"sku":"FPB-20SPSBR14TPSI-N","price":1929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fpb-20spsbr14tpsi-n-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-p","title":"Firegear Pro Series 20-Inch Square Drop-In Pan Propane Fire Pit Burner System with 14-Inch Brass Spur and TPSI Ignition - FPB-20SPSBR14TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-20SPSBR14TPSI-P is a complete square fire pit burner system for propane: a 20-inch square stainless drop-in pan carrying a 14-inch Pro Series brass Spur burner rated at 125,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, three on each leg of the 14-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-20-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-20spsbr14tpsi-n\"\u003eFPB-20SPSBR14TPSI-N\u003c\/a\u003e; for a round pit of the same output see the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-P\u003c\/a\u003e (also 125,000 Btu), or for a larger square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e (21-inch burner, 175,000 Btu). You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 20-1\/4 to 21 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e125,000 Btu\/hr on propane:\u003c\/strong\u003e the 14-inch burner in Firegear's smallest square Pro Series drop-in pan, rated the same as the 19-inch round drop-in; the 26-inch and larger square pans use the 21-inch burner at 175,000 Btu\/hr.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e14-inch brass Spur burner, three injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 20-1\/4 to 21-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-20SPSBR14TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e20 in. square stainless drop-in pan (PAN-SS20S), 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e20-1\/4 in. minimum to 21 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e14 in. Pro Series brass Spur burner, three injectors per leg (propane); burner part FG-PSBR-BS14-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e125,000 Btu\/hr (36.63 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e20 in. square stainless drop-in pan (PAN-SS20S) with 14 in. Pro Series propane Spur burner (FG-PSBR-BS14-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with a 20-1\/4 to 21 in. opening (Firegear's ready-to-finish square enclosures are cut for larger pans; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 20-1\/4 to 21 inches and do not exceed the maximum. Firegear highly recommends a FlexFrame kit for every installation. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 125,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (including carbon monoxide from fuel combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634951979287,"sku":"FPB-20SPSBR14TPSI-P","price":1929.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-20-inch-square-drop-in-pan-propane-fire-fpb-20spsbr14tpsi-p-burner-pan-top.jpg?v=1794342503"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003eFPB-25RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-n\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-N\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952044823,"sku":"FPB-25RPSBR21TPSI-N","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fpb-25rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342504"},{"product_id":"firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p","title":"Firegear Pro Series 25-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 25-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003eFPB-25RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-19-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-14-inch-brass-spur-and-tpsi-ignition-fpb-19rpsbr14tpsi-p\"\u003e19-inch round drop-in FPB-19RPSBR14TPSI-P\u003c\/a\u003e (14-inch burner, 125,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 25-1\/4 to 26 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in the smallest round pan that takes the 21-inch burner (Firegear's 19-inch round uses a 14-inch burner rated at 125,000 Btu\/hr).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 25-1\/4 to 26-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. round stainless drop-in pan (PAN-SS25R), 25 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e25-1\/4 in. minimum to 26 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. round stainless drop-in pan (PAN-SS25R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 25-1\/4 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 25-1\/4 to 26 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952175895,"sku":"FPB-25RPSBR21TPSI-P","price":2169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-fpb-25rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n","title":"Firegear Pro Series 25-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 25-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003eFPB-25SFPSBR21TPSI-P\u003c\/a\u003e; for a larger square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch FPB-30SFPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch FPB-34SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 23 inches across and no larger than the 25-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 30 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, in the smallest square disc of the range, for a compact square pit or table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 25-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 23 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. square flat stainless disc (Pan-SS25SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e23 in. minimum; do not exceed the 25 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. square flat stainless disc (Pan-SS25SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with an opening of 23 to 25 in. (Firegear's ready-to-finish square enclosures are cut for larger discs; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 23 inches and no larger than the 25-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952241431,"sku":"FPB-25SFPSBR21TPSI-N","price":2029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fpb-25sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342514"},{"product_id":"firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p","title":"Firegear Pro Series 25-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-25SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-25SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 25-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003eFPB-25SFPSBR21TPSI-N\u003c\/a\u003e; for a larger square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch FPB-30SFPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch FPB-34SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 23 inches across and no larger than the 25-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 30 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, in the smallest square disc of the range, for a compact square pit or table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 25-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 23 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-25SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e25 in. square flat stainless disc (Pan-SS25SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e23 in. minimum; do not exceed the 25 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e25 in. square flat stainless disc (Pan-SS25SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure with an opening of 23 to 25 in. (Firegear's ready-to-finish square enclosures are cut for larger discs; ask us before you order one)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 23 inches and no larger than the 25-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952339735,"sku":"FPB-25SFPSBR21TPSI-P","price":2029.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-fpb-25sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n","title":"Firegear Pro Series 26-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003eFPB-26DPSBR21TPSI-P\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch FPB-29DPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003e34-inch FPB-34DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952372503,"sku":"FPB-26DPSBR21TPSI-N","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-fpb-26dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p","title":"Firegear Pro Series 26-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 26-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003eFPB-26DPSBR21TPSI-N\u003c\/a\u003e; for a larger round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch FPB-29DPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003e34-inch FPB-34DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003e25-inch square flat pan FPB-25SFPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 24 inches across and no larger than the 26-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 29, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 26-inch disc gives that output in a smaller round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 26-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 24 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. round flat stainless disc (PAN-SS26D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e24 in. minimum; do not exceed the 26 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. round flat stainless disc (PAN-SS26D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 24 to 26 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 24 inches and no larger than the 26-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952438039,"sku":"FPB-26DPSBR21TPSI-P","price":2069.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-fpb-26dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n","title":"Firegear Pro Series 26-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26SPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26SPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 26-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003eFPB-26SPSBR21TPSI-P\u003c\/a\u003e; for a larger square pit see the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e or \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 26-1\/4 to 27 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 32-inch square and 25, 29 and 33-inch round Spur drop-in systems, in a square pan 6 inches smaller per side than the 32-inch square.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 26-1\/4 to 27-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26SPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. square stainless drop-in pan (PAN-SS26S), 26 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e26-1\/4 in. minimum to 27 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. square stainless drop-in pan (PAN-SS26S) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 26-1\/4 to 27 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 26-1\/4 to 27 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634952569111,"sku":"FPB-26SPSBR21TPSI-N","price":2199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fpb-26spsbr21tpsi-n-burner-pan-top.jpg?v=1794342514"},{"product_id":"firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p","title":"Firegear Pro Series 26-Inch Square Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-26SPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-26SPSBR21TPSI-P is a complete square fire pit burner system for propane: a 26-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003eFPB-26SPSBR21TPSI-N\u003c\/a\u003e; for a larger square pit see the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e or \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 26-1\/4 to 27 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 32-inch square and 25, 29 and 33-inch round Spur drop-in systems, in a square pan 6 inches smaller per side than the 32-inch square.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 26-1\/4 to 27-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-26SPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e26 in. square stainless drop-in pan (PAN-SS26S), 26 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e26-1\/4 in. minimum to 27 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e26 in. square stainless drop-in pan (PAN-SS26S) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 26-1\/4 to 27 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 26-1\/4 to 27 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634953322775,"sku":"FPB-26SPSBR21TPSI-P","price":2199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-fpb-26spsbr21tpsi-p-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003eFPB-29DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-n\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954076439,"sku":"FPB-29DPSBR21TPSI-N","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-fpb-29dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003eFPB-29DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26dpsbr21tpsi-p\"\u003e26-inch round flat pan FPB-26DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 27 inches across and no larger than the 29-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 26, 32 and 34-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner, so the 29-inch disc gives that output in a mid-size round pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 29-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 27 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round flat stainless disc (PAN-SS29D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e27 in. minimum; do not exceed the 29 in. disc diameter (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round flat stainless disc (PAN-SS29D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 27 to 29 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 27 inches and no larger than the 29-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954240279,"sku":"FPB-29DPSBR21TPSI-P","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-fpb-29dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003eFPB-29RPSBR21TPSI-P\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-n\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954305815,"sku":"FPB-29RPSBR21TPSI-N","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fpb-29rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p","title":"Firegear Pro Series 29-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-29RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-29RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 29-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003eFPB-29RPSBR21TPSI-N\u003c\/a\u003e; for a larger round pit see the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e, for a smaller one the \u003ca href=\"\/products\/firegear-pro-series-25-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25rpsbr21tpsi-p\"\u003e25-inch round drop-in FPB-25RPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 30-1\/4 to 31 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 33-inch round and 26 and 32-inch square Spur drop-in systems, in a mid-size 29-inch pan between the 25 and 33-inch rounds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 30-1\/4 to 31-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-29RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e29 in. round stainless drop-in pan (PAN-GV29R), 29 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e30-1\/4 in. minimum to 31 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e29 in. round stainless drop-in pan (PAN-GV29R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 30-1\/4 to 31 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 30-1\/4 to 31 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954404119,"sku":"FPB-29RPSBR21TPSI-P","price":2259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-fpb-29rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342515"},{"product_id":"firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n","title":"Firegear Pro Series 30-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-30SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-30SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 30-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003eFPB-30SFPSBR21TPSI-P\u003c\/a\u003e; for other square flat-pan pits see the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-n\"\u003e25-inch FPB-25SFPSBR21TPSI-N\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch FPB-34SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-N\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 28 inches across and no larger than the 30-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, so the 30-inch disc gives that output in a mid-size square pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 30-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 28 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-30SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e30 in. square flat stainless disc (PAN-SS30SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e28 in. minimum; do not exceed the 30 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 in. square flat stainless disc (PAN-SS30SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 28 to 30 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 28 inches and no larger than the 30-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954469655,"sku":"FPB-30SFPSBR21TPSI-N","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fpb-30sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342526"},{"product_id":"firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p","title":"Firegear Pro Series 30-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-30SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-30SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 30-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003eFPB-30SFPSBR21TPSI-N\u003c\/a\u003e; for other square flat-pan pits see the \u003ca href=\"\/products\/firegear-pro-series-25-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-25sfpsbr21tpsi-p\"\u003e25-inch FPB-25SFPSBR21TPSI-P\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch FPB-34SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-P\u003c\/a\u003e (all also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 28 inches across and no larger than the 30-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, so the 30-inch disc gives that output in a mid-size square pit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 30-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 28 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-30SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e30 in. square flat stainless disc (PAN-SS30SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e28 in. minimum; do not exceed the 30 in. disc size (Firegear Table 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 in. square flat stainless disc (PAN-SS30SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 28 to 30 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 28 inches and no larger than the 30-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954666263,"sku":"FPB-30SFPSBR21TPSI-P","price":2129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-fpb-30sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n","title":"Firegear Pro Series 32-Inch Square Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-32SPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-32SPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 32-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003eFPB-32SPSBR21TPSI-P\u003c\/a\u003e; for a smaller square pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-n\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 32-1\/4 to 33 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25, 29 and 33-inch round and 26-inch square Spur drop-in systems, spread over the largest square pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 32-1\/4 to 33-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-32SPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e32 in. square stainless drop-in pan (PAN-SS32S), 32 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32-1\/4 in. minimum to 33 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e32 in. square stainless drop-in pan (PAN-SS32S) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32-1\/4 to 33 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 32-1\/4 to 33 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954764567,"sku":"FPB-32SPSBR21TPSI-N","price":2359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fpb-32spsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p","title":"Firegear Pro Series 32-Inch Square Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-32SPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-32SPSBR21TPSI-P is a complete square fire pit burner system for propane: a 32-inch square stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003eFPB-32SPSBR21TPSI-N\u003c\/a\u003e; for a smaller square pit see the \u003ca href=\"\/products\/firegear-pro-series-26-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-26spsbr21tpsi-p\"\u003e26-inch square drop-in FPB-26SPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a round pit the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 32-1\/4 to 33 inches on each side, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25, 29 and 33-inch round and 26-inch square Spur drop-in systems, spread over the largest square pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 32-1\/4 to 33-inch square opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-32SPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e32 in. square stainless drop-in pan (PAN-SS32S), 32 in. square inside dimension, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32-1\/4 in. minimum to 33 in. maximum, each side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e32 in. square stainless drop-in pan (PAN-SS32S) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32-1\/4 to 33 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 32-1\/4 to 33 inches on each side and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634954928407,"sku":"FPB-32SPSBR21TPSI-P","price":2359.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-fpb-32spsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003eFPB-33RPSBR21TPSI-P\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-n\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-N\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955026711,"sku":"FPB-33RPSBR21TPSI-N","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fpb-33rpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p","title":"Firegear Pro Series 33-Inch Round Drop-In Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-33RPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-33RPSBR21TPSI-P is a complete round fire pit burner system for propane: a 33-inch round stainless drop-in pan carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The pan drops into the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003eFPB-33RPSBR21TPSI-N\u003c\/a\u003e; for a smaller round pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29rpsbr21tpsi-p\"\u003e29-inch round drop-in FPB-29RPSBR21TPSI-P\u003c\/a\u003e (also 175,000 Btu), or for a square pit the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be 34-1\/4 to 35 inches across, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the same rating as Firegear's 25 and 29-inch round and 26 and 32-inch square Spur drop-in systems, spread over the largest pan in Firegear's Spur drop-in range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrop-in stainless pan, 2-1\/2 inches deep:\u003c\/strong\u003e it sits in a 34-1\/4 to 35-inch opening and lifts out, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, drop-in pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-33RPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: drop-in pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e33 in. round stainless drop-in pan (PAN-GV33R), 33 in. inside diameter, 2-1\/2 in. deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e34-1\/4 in. minimum to 35 in. maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e16 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; 24 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e33 in. round stainless drop-in pan (PAN-GV33R) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (#20-025)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 34-1\/4 to 35 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to 34-1\/4 to 35 inches and do not exceed the maximum. Keep the pan removable for service, and do not let the coping or cap overlap the pan unless it lifts off easily; the pan lip must stay unobstructed.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 16 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, with a 24 in. maximum overhang, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the pan, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Drop-In_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burner, Round and Square Drop-In Pans with TPSI System, installation and operating instructions #20-025, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955125015,"sku":"FPB-33RPSBR21TPSI-P","price":2369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-fpb-33rpsbr21tpsi-p-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n","title":"Firegear Pro Series 34-Inch Round Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-N is a complete round fire pit burner system for natural gas: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003eFPB-34DPSBR21TPSI-P\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-n\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-N\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-n\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955288855,"sku":"FPB-34DPSBR21TPSI-N","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-fpb-34dpsbr21tpsi-n-burner-pan-top.jpg?v=1794342526"},{"product_id":"firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p","title":"Firegear Pro Series 34-Inch Round Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34DPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34DPSBR21TPSI-P is a complete round fire pit burner system for propane: a 34-inch round flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a round fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003eFPB-34DPSBR21TPSI-N\u003c\/a\u003e; for a smaller round flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-29-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-29dpsbr21tpsi-p\"\u003e29-inch round flat pan FPB-29DPSBR21TPSI-P\u003c\/a\u003e, for a square pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003e34-inch square flat pan FPB-34SFPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-33-inch-round-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-33rpsbr21tpsi-p\"\u003e33-inch round drop-in FPB-33RPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e Firegear's largest round flat-pan Spur system, at the same rating as its 26, 29 and 32-inch round and 25, 30 and 34-inch square flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series round burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34DPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eRound fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. round flat stainless disc (PAN-SS34D), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc diameter (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. round flat stainless disc (PAN-SS34D) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible round enclosure; Firegear's ready-to-finish round enclosures include the \u003ca href=\"\/products\/firegear-42-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r42\"\u003e42 in. RTF-R42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r48\"\u003e48 in. RTF-R48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-inch-round-ready-to-finish-fire-pit-enclosure-rtf-r60\"\u003e60 in. RTF-R60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc diameter. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/round-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Round Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955354391,"sku":"FPB-34DPSBR21TPSI-P","price":2229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-fpb-34dpsbr21tpsi-p-burner-pan-top.jpg?v=1794342537"},{"product_id":"firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n","title":"Firegear Pro Series 34-Inch Square Flat Pan Natural Gas Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34SFPSBR21TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34SFPSBR21TPSI-N is a complete square fire pit burner system for natural gas: a 34-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The propane version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p\"\u003eFPB-34SFPSBR21TPSI-P\u003c\/a\u003e; for a smaller square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-n\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-N\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-n\"\u003e34-inch round flat pan FPB-34DPSBR21TPSI-N\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-n\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on natural gas:\u003c\/strong\u003e Firegear's largest square flat-pan Spur system, at the same rating as its 25 and 30-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34SFPSBR21TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. square flat stainless disc (PAN-SS34SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc size (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (natural gas); burner part FG-PSBR-BS21-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#61 (0.039 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. square flat stainless disc (PAN-SS34SF) with 21 in. Pro Series natural gas Spur burner (FG-PSBR-BS21-NG)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955452695,"sku":"FPB-34SFPSBR21TPSI-N","price":2189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fpb-34sfpsbr21tpsi-n-burner-pan-top-view.jpg?v=1794342537"},{"product_id":"firegear-pro-series-34-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-p","title":"Firegear Pro Series 34-Inch Square Flat Pan Propane Fire Pit Burner System with 21-Inch Brass Spur and TPSI Ignition - FPB-34SFPSBR21TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series FPB-34SFPSBR21TPSI-P is a complete square fire pit burner system for propane: a 34-inch square flat stainless disc carrying a 21-inch Pro Series brass Spur burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. The flat disc sits over the opening of a square fire pit or fire table enclosure that you or your builder make from non-combustible materials, and the burner is then covered with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series Spur burner feeds its flame through many individual brass injectors, four on each leg of the 21-inch burner, instead of one main orifice, for a fuller flame across the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-34-inch-square-flat-pan-natural-gas-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34sfpsbr21tpsi-n\"\u003eFPB-34SFPSBR21TPSI-N\u003c\/a\u003e; for a smaller square flat-pan pit see the \u003ca href=\"\/products\/firegear-pro-series-30-inch-square-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-30sfpsbr21tpsi-p\"\u003e30-inch square flat pan FPB-30SFPSBR21TPSI-P\u003c\/a\u003e, for a round pit the \u003ca href=\"\/products\/firegear-pro-series-34-inch-round-flat-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-34dpsbr21tpsi-p\"\u003e34-inch round flat pan FPB-34DPSBR21TPSI-P\u003c\/a\u003e (both also 175,000 Btu), or for a recessed drop-in pan the \u003ca href=\"\/products\/firegear-pro-series-32-inch-square-drop-in-pan-propane-fire-pit-burner-system-with-21-inch-brass-spur-and-tpsi-ignition-fpb-32spsbr21tpsi-p\"\u003e32-inch square drop-in FPB-32SPSBR21TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: Firegear builds separate natural gas and propane models with different injectors and gas pressures, and its instructions give no conversion procedure, so choose the gas type before you order. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure opening must be at least 32 inches across and no larger than the 34-inch disc, the enclosure needs at least 18 sq. in. of cross ventilation on each side, and the gas installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e Firegear's largest square flat-pan Spur system, at the same rating as its 25 and 30-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e21-inch brass Spur burner, four injectors per leg:\u003c\/strong\u003e individual brass injectors spread the flame across the burner instead of feeding it from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat 34-inch stainless disc:\u003c\/strong\u003e it covers an opening of at least 32 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series square burner systems, flat pan, Spur burner, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eFPB-34SFPSBR21TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eSquare fire pit burner system: flat pan (disc), burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan\u003c\/th\u003e\n\u003ctd\u003e34 in. square flat stainless disc (PAN-SS34SF), 1\/16 in. listed disc depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure opening\u003c\/th\u003e\n\u003ctd\u003e32 in. minimum; do not exceed the 34 in. disc size (Firegear Table 1, dimension B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003e21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (51.28 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane only; natural gas and propane are separate models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media\u003c\/th\u003e\n\u003ctd\u003e1 to 2 in. lava rock or media, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e34 in. square flat stainless disc (PAN-SS34SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)\u003c\/li\u003e\n\u003cli\u003eHardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188) and 5-1\/2 x 3 in. TPSI cover plate (78116)\u003c\/li\u003e\n\u003cli\u003eFittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the \u003ca href=\"\/products\/firegear-42-x-42-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s42\"\u003e42 x 42 in. RTF-S42\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-48-x-48-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s48\"\u003e48 x 48 in. RTF-S48\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-60-inch-square-ready-to-finish-fire-pit-enclosure-rtf-s60\"\u003e60 x 60 in. RTF-S60\u003c\/a\u003e (ask us to confirm the cut-out for a 32 to 34 in. opening before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (not supplied)\u003c\/li\u003e\n\u003cli\u003eVents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS\u003c\/li\u003e\n\u003cli\u003eFiregear FlexFrame installation brackets, which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer shut-off valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: 1 to 2 in. lava rock, lava stones or fire glass\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 32 inches and no larger than the 34-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu\/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1\/2 psig and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_RoundSquare_Spur_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/square-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Square Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/support\/all-instructions\" target=\"_blank\" rel=\"noopener\"\u003eFiregear installation instructions library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634955518231,"sku":"FPB-34SFPSBR21TPSI-P","price":2189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-34-inch-square-flat-pan-propane-fire-fpb-34sfpsbr21tpsi-p-burner-pan-top.jpg?v=1794342538"},{"product_id":"firegear-pro-series-ironwood-steel-fire-pit-log-set-large-l-iw-lg","title":"Firegear Pro Series Ironwood Steel Fire Pit Log Set, Large - L-IW-LG","description":"\u003ch2\u003eFiregear Pro Series Ironwood Steel Fire Pit Log Set, Large\u003c\/h2\u003e\n\u003cp\u003eA decorative log set that gives a gas fire pit the look of a wood fire.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eArranged over the burner, the Firegear Pro Series Ironwood Steel Fire Pit Log Set, Large adds the shape and texture of a campfire to a gas fire feature, without hauling wood or cleaning out ash.\u003c\/p\u003e\n\u003cp\u003eThe logs are steel, a modern alternative to refractory concrete log sets.\u003c\/p\u003e\n\u003cp\u003eCheck the set size against your burner pan before ordering.\u003c\/p\u003e\n\u003cp\u003eNot sure which set fits your burner? Our team can help you match it. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eSteel construction\u003c\/li\u003e\n\u003cli\u003eFor gas fire pits and fire tables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eL-IW-LG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eFire pit log set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634958663959,"sku":"L-IW-LG","price":2459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-ironwood-steel-fire-pit-log-set-large-l-iw-lg-log-set.jpg?v=1794342543"},{"product_id":"firegear-pro-series-ironwood-steel-fire-pit-log-set-11-piece-l-iw-med","title":"Firegear Pro Series Ironwood Steel Fire Pit Log Set, 11-Piece - L-IW-MED","description":"\u003ch2\u003eFiregear Pro Series Ironwood Steel Fire Pit Log Set, 11-Piece\u003c\/h2\u003e\n\u003cp\u003eA decorative log set that gives a gas fire pit the look of a wood fire.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eArranged over the burner, the Firegear Pro Series Ironwood Steel Fire Pit Log Set, 11-Piece adds the shape and texture of a campfire to a gas fire feature, without hauling wood or cleaning out ash.\u003c\/p\u003e\n\u003cp\u003eThe logs are steel, a modern alternative to refractory concrete log sets.\u003c\/p\u003e\n\u003cp\u003eRecommended for 29\" and 33\" Round Drop-In Pans, 29\" \u0026amp; 34\" Round Discs, 30\", 34\" Square Flat Pans.\u003c\/p\u003e\n\u003cp\u003eNot sure which set fits your burner? Our team can help you match it. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eSteel construction\u003c\/li\u003e\n\u003cli\u003e11-Piece\u003c\/li\u003e\n\u003cli\u003eFor gas fire pits and fire tables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eL-IW-MED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eFire pit log set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight (as listed by distributor)\u003c\/th\u003e\n\u003ctd\u003e27 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634958696727,"sku":"L-IW-MED","price":1549.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-ironwood-steel-fire-pit-log-set-11-piece-l-iw-med-log-set.jpg?v=1794342543"},{"product_id":"firegear-pro-series-ironwood-steel-fire-pit-log-set-14-piece-xl-l-iw-xl","title":"Firegear Pro Series Ironwood Steel Fire Pit Log Set, 14-Piece XL - L-IW-XL","description":"\u003ch2\u003eFiregear Pro Series Ironwood Steel Fire Pit Log Set, 14-Piece XL\u003c\/h2\u003e\n\u003cp\u003eA decorative log set that gives a gas fire pit the look of a wood fire.\u003c\/p\u003e\n\u003ch6\u003eDescription\u003c\/h6\u003e\n\u003cp\u003eArranged over the burner, the Firegear Pro Series Ironwood Steel Fire Pit Log Set, 14-Piece XL adds the shape and texture of a campfire to a gas fire feature, without hauling wood or cleaning out ash.\u003c\/p\u003e\n\u003cp\u003eThe logs are steel, a modern alternative to refractory concrete log sets.\u003c\/p\u003e\n\u003cp\u003eCheck the set size against your burner pan before ordering.\u003c\/p\u003e\n\u003cp\u003eNot sure which set fits your burner? Our team can help you match it. M\u0026amp;K Grills is an authorized Firegear dealer. Free shipping.\u003c\/p\u003e\n\u003ch6\u003eFeatures\u003c\/h6\u003e\n\u003cul\u003e\n\u003cli\u003eSteel construction\u003c\/li\u003e\n\u003cli\u003e14-Piece\u003c\/li\u003e\n\u003cli\u003eFor gas fire pits and fire tables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eSpecifications\u003c\/h6\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eL-IW-XL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eFire pit log set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePieces\u003c\/th\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634958926103,"sku":"L-IW-XL","price":2899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-ironwood-steel-fire-pit-log-set-14-l-iw-xl-log-set.jpg?v=1794342543"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-N is a complete linear fire pit burner system for natural gas: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 80,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003eLOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e80,000 Btu\/hr on natural gas:\u003c\/strong\u003e the smallest of Firegear's flat H TPSI systems, sized for a 30-inch linear fire pit or fire table; the 36-inch version is rated 95,000 Btu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 20 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., 20 individual injectors (natural gas); burner part FG-PSBR-H24-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e80,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series natural gas H burner (FG-PSBR-H24-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 80,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959417623,"sku":"LOF-3010PS246TPSI-N","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-lof-3010ps246tpsi-n-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p","title":"Firegear Pro Series 30 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3010PS246TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3010PS246TPSI-P is a complete linear fire pit burner system for propane: a 30 x 10-inch flat pan carrying a Pro Series brass H burner rated at 110,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003eLOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e110,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 30-inch linear fire pit or fire table, with more output than the 80,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 24-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3010PS246TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e30 in. x 10 in. (pan 78124)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 24 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H24-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e110,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 40 lb fire glass, or 20 lb lava stones (Firegear media chart for 30 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e30 x 10 in. flat pan (78124) with Pro Series propane H burner (FG-PSBR-H24-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 30 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959450391,"sku":"LOF-3010PS246TPSI-P","price":1969.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-lof-3010ps246tpsi-p-burner-and-gas.jpg?v=1794342526"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-N is a complete linear fire pit burner system for natural gas: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 95,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003eLOF-3610PS306TPSI-P\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-n\"\u003e30 x 10-inch LOF-3010PS246TPSI-N (80,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e95,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (80,000 Btu) and 48-inch (120,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 24 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., 24 individual injectors (natural gas); burner part FG-PSBR-H30-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e95,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series natural gas H burner (FG-PSBR-H30-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 75,000 Btu\/hr for 1\/2 in. and 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so at 95,000 Btu\/hr have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959515927,"sku":"LOF-3610PS306TPSI-N","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-lof-3610ps306tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p","title":"Firegear Pro Series 36 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-3610PS306TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-3610PS306TPSI-P is a complete linear fire pit burner system for propane: a 36 x 10-inch flat pan carrying a Pro Series brass H burner rated at 115,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003eLOF-3610PS306TPSI-N (95,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-30-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3010ps246tpsi-p\"\u003e30 x 10-inch propane LOF-3010PS246TPSI-P (110,000 Btu)\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e115,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 36-inch linear fire pit or fire table, between Firegear's 30-inch (110,000 Btu) and 48-inch (150,000 Btu) propane flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 30-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-3610PS306TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e36 in. x 10 in. (pan 78125)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 30 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H30-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e115,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 96 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e20 lb lava rock, or 50 lb fire glass, or 20 lb lava stones (Firegear media chart for 36 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e36 x 10 in. flat pan (78125) with Pro Series propane H burner (FG-PSBR-H30-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit for a 36 x 10 in. pan before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 96 in. to a combustible ceiling (30 and 36 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959581463,"sku":"LOF-3610PS306TPSI-P","price":2299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-lof-3610ps306tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-N is a complete linear fire pit burner system for natural gas: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 120,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003eLOF-4810PS406TPSI-P (150,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003e60 x 10-inch LOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-n\"\u003e36 x 10-inch LOF-3610PS306TPSI-N\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e120,000 Btu\/hr on natural gas:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, between Firegear's 36-inch (95,000 Btu) and 60-inch (160,000 Btu) flat H systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 32 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, natural gas pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., 32 individual injectors (natural gas); burner part FG-PSBR-H40-NG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e120,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series natural gas H burner (FG-PSBR-H40-NG)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its product guide chart lists 160,000 Btu\/hr for 3\/4 in. natural gas pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959614231,"sku":"LOF-4810PS406TPSI-N","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-lof-4810ps406tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p","title":"Firegear Pro Series 48 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-4810PS406TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-4810PS406TPSI-P is a complete linear fire pit burner system for propane: a 48 x 10-inch flat pan carrying a Pro Series brass H burner rated at 150,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003eLOF-4810PS406TPSI-N (120,000 Btu)\u003c\/a\u003e; for a longer pit see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003e60 x 10-inch propane LOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e, or for a shorter one the \u003ca href=\"\/products\/firegear-pro-series-36-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-3610ps306tpsi-p\"\u003e36 x 10-inch propane LOF-3610PS306TPSI-P\u003c\/a\u003e. You can also browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150,000 Btu\/hr on propane:\u003c\/strong\u003e sized for a 48-inch linear fire pit or fire table, with more output than the 120,000 Btu natural gas version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 40-inch burner instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-4810PS406TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e48 in. x 10 in. (pan 78126)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 40 in. x 6-3\/4 in., multiple individual brass injectors (propane); burner part FG-PSBR-H40-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e150,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e30 lb lava rock, or 60 lb fire glass, or 30 lb lava stones (Firegear media chart for 48 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e48 x 10 in. flat pan (78126) with Pro Series propane H burner (FG-PSBR-H40-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-60-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6024\"\u003e60 x 24 in. RTF-L6024\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-60-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l6034\"\u003e60 x 34 in. RTF-L6034\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959646999,"sku":"LOF-4810PS406TPSI-P","price":2399.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-lof-4810ps406tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Natural Gas Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-N","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-N is a complete linear fire pit burner system for natural gas: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 160,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors (40 on this natural gas model) instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The propane version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p\"\u003eLOF-6010PS506TPSI-P (175,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI-N\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear does not offer conversion kits for Pro Series systems. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e160,000 Btu\/hr on natural gas:\u003c\/strong\u003e the highest output of Firegear's 10-inch-wide Pro Series flat H systems, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner with 40 injectors:\u003c\/strong\u003e individual injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete gas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-N (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, 40 individual injectors (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#68 (0.031 in.), natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e160,000 Btu\/hr (natural gas)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eNatural gas; ships set for NG and cannot be field converted (propane model LOF-6010PS506TPSI-P, 175,000 Btu\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003eNatural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series natural gas H burner\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003eNatural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for runs over 20 ft on units above 100,000 Btu; its product guide chart shows 3\/4 in. pipe at its 160,000 Btu limit on a 20 ft run, so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959712535,"sku":"LOF-6010PS506TPSI-N","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-lof-6010ps506tpsi-n-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-p","title":"Firegear Pro Series 60 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-P","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear Pro Series LOF-6010PS506TPSI-P is a complete linear fire pit burner system for propane: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 175,000 Btu\/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.\u003c\/p\u003e\n\u003cp\u003eFiregear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003eLOF-6010PS506TPSI-N (160,000 Btu)\u003c\/a\u003e; for a shorter pit see the \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-propane-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-p\"\u003e48 x 10-inch propane LOF-4810PS406TPSI-P\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e175,000 Btu\/hr on propane:\u003c\/strong\u003e the highest rating in Firegear's Pro Series flat H TPSI model table, for a long linear fire pit or fire table.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrass Pro Series H burner:\u003c\/strong\u003e many individual brass injectors spread the flame along the 60-inch pan instead of feeding from one orifice.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTPSI safety pilot:\u003c\/strong\u003e a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas train in the box:\u003c\/strong\u003e Copreci high-capacity valve, 46-inch 1\/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable pan for service:\u003c\/strong\u003e the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eListed for 0 to 4,500 ft:\u003c\/strong\u003e in the U.S. and Canada, installed to NFPA 54 \/ ANSI Z223.1 or CSA B149.1 where there is no local code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ePro Series linear H burner systems, flat pan, TPSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLOF-6010PS506TPSI-P (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eLinear fire pit burner system: flat pan, burner and ignition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePan size\u003c\/th\u003e\n\u003ctd\u003e60 in. x 10 in. (pan 78127)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner\u003c\/th\u003e\n\u003ctd\u003ePro Series brass H burner, 6-3\/4 in. wide, multiple individual brass injectors (propane); burner part FG-PSBR-H50-LP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInjector size\u003c\/th\u003e\n\u003ctd\u003e#72 (0.025 in.), propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e175,000 Btu\/hr (propane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003ePropane; ships set for LP and cannot be field converted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInlet gas pressure\u003c\/th\u003e\n\u003ctd\u003ePropane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIgnition\u003c\/th\u003e\n\u003ctd\u003eTPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas valve\u003c\/th\u003e\n\u003ctd\u003eCopreci high capacity valve (68001599) with control knob CN-ALHC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas connection\u003c\/th\u003e\n\u003ctd\u003e1\/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1\/2 in. male flare fitting on your shut-off valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePilot leads\u003c\/th\u003e\n\u003ctd\u003e48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEnclosure ventilation\u003c\/th\u003e\n\u003ctd\u003eAt least 18 sq. in. of cross ventilation per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearances to combustibles\u003c\/th\u003e\n\u003ctd\u003e36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElevation\u003c\/th\u003e\n\u003ctd\u003e0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eOutdoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInstallation codes\u003c\/th\u003e\n\u003ctd\u003eLocal codes; otherwise ANSI Z223.1\/NFPA 54 (U.S.) or CSA B149.1 (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFire media (approx.)\u003c\/th\u003e\n\u003ctd\u003e40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNot included\u003c\/th\u003e\n\u003ctd\u003eEnclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e60 x 10 in. flat pan (78127) with Pro Series propane H burner (FG-PSBR-H50-LP)\u003c\/li\u003e\n\u003cli\u003eBrass burner support and hardware bag (10850), including injector hoods\u003c\/li\u003e\n\u003cli\u003eCopreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)\u003c\/li\u003e\n\u003cli\u003e1\/2 in. stainless flex gas line, 46 in. (T-200-9898-46)\u003c\/li\u003e\n\u003cli\u003ePropane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)\u003c\/li\u003e\n\u003cli\u003eManual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab\u003c\/li\u003e\n\u003cli\u003eTPSI faceplate \/ control panel (78188)\u003c\/li\u003e\n\u003cli\u003eFlare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers\u003c\/li\u003e\n\u003cli\u003eFiregear installation and operating instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eA non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the \u003ca href=\"\/products\/firegear-84-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8424\"\u003e84 x 24 in. RTF-L8424\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-84-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l8434\"\u003e84 x 34 in. RTF-L8434\u003c\/a\u003e (ask us to confirm the fit before you order)\u003c\/li\u003e\n\u003cli\u003eManual gas shut-off valve with a 1\/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS \/ PAVER-VENT-6-LNTS\u003c\/li\u003e\n\u003cli\u003eFlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation\u003c\/li\u003e\n\u003cli\u003ePaver control panel plate PAVER-CP-TPSI\u003c\/li\u003e\n\u003cli\u003eE-Stop 1-hour timer valve ESTOP1-0H\u003c\/li\u003e\n\u003cli\u003eFire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWho installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1\/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.\u003c\/li\u003e\n\u003cli\u003eEnclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.\u003c\/li\u003e\n\u003cli\u003eVentilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.\u003c\/li\u003e\n\u003cli\u003eClearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.\u003c\/li\u003e\n\u003cli\u003eGas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1\/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3\/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu\/hr for 1\/2 in. pipe and 393,000 Btu\/hr for 3\/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.\u003c\/li\u003e\n\u003cli\u003eMedia: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.\u003c\/li\u003e\n\u003cli\u003eWeather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.\u003c\/li\u003e\n\u003cli\u003eLighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.\u003c\/p\u003e\n\u003cp\u003eCoverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/5-Burner-Systems\/Pro-Series\/Burner-Systems_Pro_Flat_H_TPSI.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/firepit-burner-systems\/linear-h-pro-burner-systems\" target=\"_blank\" rel=\"noopener\"\u003eFiregear Linear H Pro Burner Systems product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634959745303,"sku":"LOF-6010PS506TPSI-P","price":2669.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-pro-series-60-x-10-inch-linear-flat-pan-propane-lof-6010ps506tpsi-p-burner-and-gas.jpg?v=1794342538"},{"product_id":"firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar","title":"Firegear Lume Fire Pit Surround Package - Arctic White - LUME-SUR1-AR","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear LUME Surround 1 in Arctic, LUME-SUR1-AR, is a smoke-less wood-burning fire pit package: a 42-inch GFRC (glass fiber reinforced concrete) fire bowl paired with a LUME smoke-less wood-burning insert and a stainless steel lid. Firegear lists the surround at 42 in. wide and 18 in. tall, on a 20-inch-wide base, with a 23-1\/2-inch interior diameter and a weight of 200 lb.\u003c\/p\u003e\n\u003cp\u003eThe LUME is Firegear's smoke-less wood fire pit, built from 100% commercial-grade stainless steel and designed to burn more efficiently and emit less smoke. Firegear explains that LUME fire pits use the smoke as fuel: air heated between two walls is forced out through the upper holes, adding oxygen to the fire, and that heat ignites the smoke (unburned fuel). The same package comes in four GFRC colors; see \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch\"\u003eChocolate (LUME-SUR1-CH)\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra\"\u003eRaven (LUME-SUR1-RA)\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl\"\u003eSlate (LUME-SUR1-SL)\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e and \u003ca href=\"\/collections\/fire-pits-and-tables\"\u003efire pits and fire tables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this is a wood-burning fire pit, not a gas fire feature, so it needs no gas line, burner or ignition, and it needs a place where you are allowed to burn wood. Firegear does not publish clearances, a placement surface or an owner's manual for the Surround 1 in the documents we found, so ask us before you order if your site has a specific requirement. A custom-fitted weather cover, COV-SUR1, is available separately.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke-less wood burning:\u003c\/strong\u003e heated air from between the walls is forced into the fire through the upper holes and ignites the smoke, so the fire burns more efficiently and emits less smoke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-inch GFRC fire bowl, 18 inches tall:\u003c\/strong\u003e a finished GFRC surround around the stainless insert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade stainless steel LUME insert:\u003c\/strong\u003e Firegear builds the LUME from 100% commercial-grade stainless steel and describes it as low maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel lid included:\u003c\/strong\u003e part of the Surround 1 package, so the fire pit can be closed when it is not in use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour colors:\u003c\/strong\u003e Arctic, Chocolate, Raven and Slate GFRC, each 200 lb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitted weather cover available:\u003c\/strong\u003e Firegear's COV-SUR1 is 100% water-resistant, UV-protected to prevent fading and custom fitted to the Surround 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eLUME smoke-less wood-burning fire pits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackage\u003c\/th\u003e\n\u003ctd\u003eLUME Surround 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-AR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning fire pit: GFRC fire bowl with smoke-less insert and lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eWood (no gas connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eArctic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e42 in. W x 18 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase width\u003c\/th\u003e\n\u003ctd\u003e20 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterior diameter\u003c\/th\u003e\n\u003ctd\u003e23-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e200 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSurround (bowl) material\u003c\/th\u003e\n\u003ctd\u003eGFRC (glass fiber reinforced concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsert material\u003c\/th\u003e\n\u003ctd\u003e100% commercial-grade stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLid\u003c\/th\u003e\n\u003ctd\u003eStainless steel, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmoke reduction\u003c\/th\u003e\n\u003ctd\u003eHeated air is forced into the fire through the upper holes and ignites the smoke (Firegear LUME design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther colors\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-AR (Arctic), LUME-SUR1-CH (Chocolate), LUME-SUR1-RA (Raven), LUME-SUR1-SL (Slate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeather cover\u003c\/th\u003e\n\u003ctd\u003eCOV-SUR1, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e42 in. GFRC fire bowl in Arctic\u003c\/li\u003e\n\u003cli\u003eLUME smoke-less wood-burning insert, commercial-grade stainless steel\u003c\/li\u003e\n\u003cli\u003eStainless steel lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eWeather cover COV-SUR1: 100% water-resistant, UV-protected, custom fitted to the Surround 1 (ask us to order it)\u003c\/li\u003e\n\u003cli\u003eFirewood\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhat Firegear publishes: the LUME literature gives the size, weight, materials, colors and how the smoke-less design works. It does not publish clearances to combustibles, a required base surface, wood size or an owner's manual for the Surround 1, so ask us before you order if you need any of these for your site.\u003c\/li\u003e\n\u003cli\u003eNo gas or electrical work: the Surround 1 burns wood, so there is no gas line, shut-off, burner or ignition to plan.\u003c\/li\u003e\n\u003cli\u003eLocal rules: wood burning is subject to local burn rules and any HOA or landlord rules; check them for your address before you order.\u003c\/li\u003e\n\u003cli\u003eWeight and handling: each surround weighs 200 lb; plan the delivery path to its final spot and the help you need to set it.\u003c\/li\u003e\n\u003cli\u003eCare: Firegear describes the LUME as low maintenance, and describes the COV-SUR1 cover as 100% water-resistant and UV-protected to prevent fading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe LUME Surround 1 is covered by Firegear's limited warranty. Firegear's warranty lists terms by component and does not name the LUME or its GFRC surround separately in the terms we have, so ask us to confirm the term for each part before you file.\u003c\/p\u003e\n\u003cp\u003eFiregear warrants its products to the end user against defects in material and workmanship. Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\/lume-surround-1\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME Surround 1 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME smoke-less fire pit range\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0354\/7607\/8636\/files\/Firegear-Lume-92822.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME literature: how the smoke-less design works, LUME models (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023, LUME, page 6 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634961187095,"sku":"LUME-SUR1-AR","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar-bowl-with-firewood.png?v=1794342490"},{"product_id":"firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch","title":"Firegear Lume Fire Pit Surround Package - Chocolate - LUME-SUR1-CH","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear LUME Surround 1 in Chocolate, LUME-SUR1-CH, is a smoke-less wood-burning fire pit package: a 42-inch GFRC (glass fiber reinforced concrete) fire bowl paired with a LUME smoke-less wood-burning insert and a stainless steel lid. Firegear lists the surround at 42 in. wide and 18 in. tall, on a 20-inch-wide base, with a 23-1\/2-inch interior diameter and a weight of 200 lb.\u003c\/p\u003e\n\u003cp\u003eThe LUME is Firegear's smoke-less wood fire pit, built from 100% commercial-grade stainless steel and designed to burn more efficiently and emit less smoke. Firegear explains that LUME fire pits use the smoke as fuel: air heated between two walls is forced out through the upper holes, adding oxygen to the fire, and that heat ignites the smoke (unburned fuel). The same package comes in four GFRC colors; see \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar\"\u003eArctic (LUME-SUR1-AR)\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra\"\u003eRaven (LUME-SUR1-RA)\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl\"\u003eSlate (LUME-SUR1-SL)\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e and \u003ca href=\"\/collections\/fire-pits-and-tables\"\u003efire pits and fire tables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this is a wood-burning fire pit, not a gas fire feature, so it needs no gas line, burner or ignition, and it needs a place where you are allowed to burn wood. Firegear does not publish clearances, a placement surface or an owner's manual for the Surround 1 in the documents we found, so ask us before you order if your site has a specific requirement. A custom-fitted weather cover, COV-SUR1, is available separately.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke-less wood burning:\u003c\/strong\u003e heated air from between the walls is forced into the fire through the upper holes and ignites the smoke, so the fire burns more efficiently and emits less smoke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-inch GFRC fire bowl, 18 inches tall:\u003c\/strong\u003e a finished GFRC surround in Chocolate around the stainless insert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade stainless steel LUME insert:\u003c\/strong\u003e Firegear builds the LUME from 100% commercial-grade stainless steel and describes it as low maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel lid included:\u003c\/strong\u003e part of the Surround 1 package, so the fire pit can be closed when it is not in use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour colors:\u003c\/strong\u003e Arctic, Chocolate, Raven and Slate GFRC, each 200 lb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitted weather cover available:\u003c\/strong\u003e Firegear's COV-SUR1 is 100% water-resistant, UV-protected to prevent fading and custom fitted to the Surround 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eLUME smoke-less wood-burning fire pits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackage\u003c\/th\u003e\n\u003ctd\u003eLUME Surround 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning fire pit: GFRC fire bowl with smoke-less insert and lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eWood (no gas connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eChocolate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e42 in. W x 18 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase width\u003c\/th\u003e\n\u003ctd\u003e20 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterior diameter\u003c\/th\u003e\n\u003ctd\u003e23-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e200 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSurround (bowl) material\u003c\/th\u003e\n\u003ctd\u003eGFRC (glass fiber reinforced concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsert material\u003c\/th\u003e\n\u003ctd\u003e100% commercial-grade stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLid\u003c\/th\u003e\n\u003ctd\u003eStainless steel, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmoke reduction\u003c\/th\u003e\n\u003ctd\u003eHeated air is forced into the fire through the upper holes and ignites the smoke (Firegear LUME design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther colors\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-AR (Arctic), LUME-SUR1-CH (Chocolate), LUME-SUR1-RA (Raven), LUME-SUR1-SL (Slate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeather cover\u003c\/th\u003e\n\u003ctd\u003eCOV-SUR1, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e42 in. GFRC fire bowl in Chocolate\u003c\/li\u003e\n\u003cli\u003eLUME smoke-less wood-burning insert, commercial-grade stainless steel\u003c\/li\u003e\n\u003cli\u003eStainless steel lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eWeather cover COV-SUR1: 100% water-resistant, UV-protected, custom fitted to the Surround 1 (ask us to order it)\u003c\/li\u003e\n\u003cli\u003eFirewood\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhat Firegear publishes: the LUME literature gives the size, weight, materials, colors and how the smoke-less design works. It does not publish clearances to combustibles, a required base surface, wood size or an owner's manual for the Surround 1, so ask us before you order if you need any of these for your site.\u003c\/li\u003e\n\u003cli\u003eNo gas or electrical work: the Surround 1 burns wood, so there is no gas line, shut-off, burner or ignition to plan.\u003c\/li\u003e\n\u003cli\u003eLocal rules: wood burning is subject to local burn rules and any HOA or landlord rules; check them for your address before you order.\u003c\/li\u003e\n\u003cli\u003eWeight and handling: each surround weighs 200 lb; plan the delivery path to its final spot and the help you need to set it.\u003c\/li\u003e\n\u003cli\u003eCare: Firegear describes the LUME as low maintenance, and describes the COV-SUR1 cover as 100% water-resistant and UV-protected to prevent fading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe LUME Surround 1 is covered by Firegear's limited warranty. Firegear's warranty lists terms by component and does not name the LUME or its GFRC surround separately in the terms we have, so ask us to confirm the term for each part before you file.\u003c\/p\u003e\n\u003cp\u003eFiregear warrants its products to the end user against defects in material and workmanship. Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\/lume-surround-1\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME Surround 1 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME smoke-less fire pit range\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0354\/7607\/8636\/files\/Firegear-Lume-92822.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME literature: how the smoke-less design works, LUME models (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023, LUME, page 6 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634961219863,"sku":"LUME-SUR1-CH","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch-bowl-with-firewood.png?v=1794342491"},{"product_id":"firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra","title":"Firegear Lume Fire Pit Surround Package - Raven - LUME-SUR1-RA","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear LUME Surround 1 in Raven, LUME-SUR1-RA, is a smoke-less wood-burning fire pit package: a 42-inch GFRC (glass fiber reinforced concrete) fire bowl paired with a LUME smoke-less wood-burning insert and a stainless steel lid. Firegear lists the surround at 42 in. wide and 18 in. tall, on a 20-inch-wide base, with a 23-1\/2-inch interior diameter and a weight of 200 lb.\u003c\/p\u003e\n\u003cp\u003eThe LUME is Firegear's smoke-less wood fire pit, built from 100% commercial-grade stainless steel and designed to burn more efficiently and emit less smoke. Firegear explains that LUME fire pits use the smoke as fuel: air heated between two walls is forced out through the upper holes, adding oxygen to the fire, and that heat ignites the smoke (unburned fuel). The same package comes in four GFRC colors; see \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar\"\u003eArctic (LUME-SUR1-AR)\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch\"\u003eChocolate (LUME-SUR1-CH)\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl\"\u003eSlate (LUME-SUR1-SL)\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e and \u003ca href=\"\/collections\/fire-pits-and-tables\"\u003efire pits and fire tables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this is a wood-burning fire pit, not a gas fire feature, so it needs no gas line, burner or ignition, and it needs a place where you are allowed to burn wood. Firegear does not publish clearances, a placement surface or an owner's manual for the Surround 1 in the documents we found, so ask us before you order if your site has a specific requirement. A custom-fitted weather cover, COV-SUR1, is available separately.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke-less wood burning:\u003c\/strong\u003e heated air from between the walls is forced into the fire through the upper holes and ignites the smoke, so the fire burns more efficiently and emits less smoke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-inch GFRC fire bowl, 18 inches tall:\u003c\/strong\u003e a finished GFRC surround in Raven around the stainless insert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade stainless steel LUME insert:\u003c\/strong\u003e Firegear builds the LUME from 100% commercial-grade stainless steel and describes it as low maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel lid included:\u003c\/strong\u003e part of the Surround 1 package, so the fire pit can be closed when it is not in use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour colors:\u003c\/strong\u003e Arctic, Chocolate, Raven and Slate GFRC, each 200 lb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitted weather cover available:\u003c\/strong\u003e Firegear's COV-SUR1 is 100% water-resistant, UV-protected to prevent fading and custom fitted to the Surround 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eLUME smoke-less wood-burning fire pits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackage\u003c\/th\u003e\n\u003ctd\u003eLUME Surround 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-RA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning fire pit: GFRC fire bowl with smoke-less insert and lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eWood (no gas connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eRaven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e42 in. W x 18 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase width\u003c\/th\u003e\n\u003ctd\u003e20 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterior diameter\u003c\/th\u003e\n\u003ctd\u003e23-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e200 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSurround (bowl) material\u003c\/th\u003e\n\u003ctd\u003eGFRC (glass fiber reinforced concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsert material\u003c\/th\u003e\n\u003ctd\u003e100% commercial-grade stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLid\u003c\/th\u003e\n\u003ctd\u003eStainless steel, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmoke reduction\u003c\/th\u003e\n\u003ctd\u003eHeated air is forced into the fire through the upper holes and ignites the smoke (Firegear LUME design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther colors\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-AR (Arctic), LUME-SUR1-CH (Chocolate), LUME-SUR1-RA (Raven), LUME-SUR1-SL (Slate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeather cover\u003c\/th\u003e\n\u003ctd\u003eCOV-SUR1, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e42 in. GFRC fire bowl in Raven\u003c\/li\u003e\n\u003cli\u003eLUME smoke-less wood-burning insert, commercial-grade stainless steel\u003c\/li\u003e\n\u003cli\u003eStainless steel lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eWeather cover COV-SUR1: 100% water-resistant, UV-protected, custom fitted to the Surround 1 (ask us to order it)\u003c\/li\u003e\n\u003cli\u003eFirewood\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhat Firegear publishes: the LUME literature gives the size, weight, materials, colors and how the smoke-less design works. It does not publish clearances to combustibles, a required base surface, wood size or an owner's manual for the Surround 1, so ask us before you order if you need any of these for your site.\u003c\/li\u003e\n\u003cli\u003eNo gas or electrical work: the Surround 1 burns wood, so there is no gas line, shut-off, burner or ignition to plan.\u003c\/li\u003e\n\u003cli\u003eLocal rules: wood burning is subject to local burn rules and any HOA or landlord rules; check them for your address before you order.\u003c\/li\u003e\n\u003cli\u003eWeight and handling: each surround weighs 200 lb; plan the delivery path to its final spot and the help you need to set it.\u003c\/li\u003e\n\u003cli\u003eCare: Firegear describes the LUME as low maintenance, and describes the COV-SUR1 cover as 100% water-resistant and UV-protected to prevent fading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe LUME Surround 1 is covered by Firegear's limited warranty. Firegear's warranty lists terms by component and does not name the LUME or its GFRC surround separately in the terms we have, so ask us to confirm the term for each part before you file.\u003c\/p\u003e\n\u003cp\u003eFiregear warrants its products to the end user against defects in material and workmanship. Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\/lume-surround-1\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME Surround 1 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME smoke-less fire pit range\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0354\/7607\/8636\/files\/Firegear-Lume-92822.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME literature: how the smoke-less design works, LUME models (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023, LUME, page 6 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634961252631,"sku":"LUME-SUR1-RA","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra-bowl.png?v=1794342491"},{"product_id":"firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl","title":"Firegear Lume Fire Pit Surround Package - Slate - LUME-SUR1-SL","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear LUME Surround 1 in Slate, LUME-SUR1-SL, is a smoke-less wood-burning fire pit package: a 42-inch GFRC (glass fiber reinforced concrete) fire bowl paired with a LUME smoke-less wood-burning insert and a stainless steel lid. Firegear lists the surround at 42 in. wide and 18 in. tall, on a 20-inch-wide base, with a 23-1\/2-inch interior diameter and a weight of 200 lb.\u003c\/p\u003e\n\u003cp\u003eThe LUME is Firegear's smoke-less wood fire pit, built from 100% commercial-grade stainless steel and designed to burn more efficiently and emit less smoke. Firegear explains that LUME fire pits use the smoke as fuel: air heated between two walls is forced out through the upper holes, adding oxygen to the fire, and that heat ignites the smoke (unburned fuel). The same package comes in four GFRC colors; see \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-arctic-white-lume-sur1-ar\"\u003eArctic (LUME-SUR1-AR)\u003c\/a\u003e, \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-chocolate-lume-sur1-ch\"\u003eChocolate (LUME-SUR1-CH)\u003c\/a\u003e and \u003ca href=\"\/products\/firegear-lume-fire-pit-surround-package-raven-lume-sur1-ra\"\u003eRaven (LUME-SUR1-RA)\u003c\/a\u003e, or browse our \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e and \u003ca href=\"\/collections\/fire-pits-and-tables\"\u003efire pits and fire tables\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this is a wood-burning fire pit, not a gas fire feature, so it needs no gas line, burner or ignition, and it needs a place where you are allowed to burn wood. Firegear does not publish clearances, a placement surface or an owner's manual for the Surround 1 in the documents we found, so ask us before you order if your site has a specific requirement. A custom-fitted weather cover, COV-SUR1, is available separately.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke-less wood burning:\u003c\/strong\u003e heated air from between the walls is forced into the fire through the upper holes and ignites the smoke, so the fire burns more efficiently and emits less smoke.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e42-inch GFRC fire bowl, 18 inches tall:\u003c\/strong\u003e a finished GFRC surround around the stainless insert.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommercial-grade stainless steel LUME insert:\u003c\/strong\u003e Firegear builds the LUME from 100% commercial-grade stainless steel and describes it as low maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel lid included:\u003c\/strong\u003e part of the Surround 1 package, so the fire pit can be closed when it is not in use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour colors:\u003c\/strong\u003e Arctic, Chocolate, Raven and Slate GFRC, each 200 lb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitted weather cover available:\u003c\/strong\u003e Firegear's COV-SUR1 is 100% water-resistant, UV-protected to prevent fading and custom fitted to the Surround 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eLUME smoke-less wood-burning fire pits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePackage\u003c\/th\u003e\n\u003ctd\u003eLUME Surround 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-SL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eWood-burning fire pit: GFRC fire bowl with smoke-less insert and lid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eWood (no gas connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColor\u003c\/th\u003e\n\u003ctd\u003eSlate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e42 in. W x 18 in. H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBase width\u003c\/th\u003e\n\u003ctd\u003e20 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInterior diameter\u003c\/th\u003e\n\u003ctd\u003e23-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e200 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSurround (bowl) material\u003c\/th\u003e\n\u003ctd\u003eGFRC (glass fiber reinforced concrete)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eInsert material\u003c\/th\u003e\n\u003ctd\u003e100% commercial-grade stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLid\u003c\/th\u003e\n\u003ctd\u003eStainless steel, included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSmoke reduction\u003c\/th\u003e\n\u003ctd\u003eHeated air is forced into the fire through the upper holes and ignites the smoke (Firegear LUME design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther colors\u003c\/th\u003e\n\u003ctd\u003eLUME-SUR1-AR (Arctic), LUME-SUR1-CH (Chocolate), LUME-SUR1-RA (Raven), LUME-SUR1-SL (Slate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeather cover\u003c\/th\u003e\n\u003ctd\u003eCOV-SUR1, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eFiregear limited warranty; see Warranty below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003e42 in. GFRC fire bowl in Slate\u003c\/li\u003e\n\u003cli\u003eLUME smoke-less wood-burning insert, commercial-grade stainless steel\u003c\/li\u003e\n\u003cli\u003eStainless steel lid\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eWeather cover COV-SUR1: 100% water-resistant, UV-protected, custom fitted to the Surround 1 (ask us to order it)\u003c\/li\u003e\n\u003cli\u003eFirewood\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhat Firegear publishes: the LUME literature gives the size, weight, materials, colors and how the smoke-less design works. It does not publish clearances to combustibles, a required base surface, wood size or an owner's manual for the Surround 1, so ask us before you order if you need any of these for your site.\u003c\/li\u003e\n\u003cli\u003eNo gas or electrical work: the Surround 1 burns wood, so there is no gas line, shut-off, burner or ignition to plan.\u003c\/li\u003e\n\u003cli\u003eLocal rules: wood burning is subject to local burn rules and any HOA or landlord rules; check them for your address before you order.\u003c\/li\u003e\n\u003cli\u003eWeight and handling: each surround weighs 200 lb; plan the delivery path to its final spot and the help you need to set it.\u003c\/li\u003e\n\u003cli\u003eCare: Firegear describes the LUME as low maintenance, and describes the COV-SUR1 cover as 100% water-resistant and UV-protected to prevent fading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe LUME Surround 1 is covered by Firegear's limited warranty. Firegear's warranty lists terms by component and does not name the LUME or its GFRC surround separately in the terms we have, so ask us to confirm the term for each part before you file.\u003c\/p\u003e\n\u003cp\u003eFiregear warrants its products to the end user against defects in material and workmanship. Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\/lume-surround-1\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME Surround 1 product page\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.firegearoutdoors.com\/products\/the-lume\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME smoke-less fire pit range\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0354\/7607\/8636\/files\/Firegear-Lume-92822.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear LUME literature: how the smoke-less design works, LUME models (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023, LUME, page 6 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634961285399,"sku":"LUME-SUR1-SL","price":2150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-lume-fire-pit-surround-package-slate-lume-sur1-sl-lifestyle-backyard.jpg?v=1794342503"},{"product_id":"firegear-108-x-24-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l10824","title":"Firegear 108 x 24-Inch Linear Ready-To-Finish Fire Pit Enclosure - RTF-L10824","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Firegear RTF-L10824 is a 108-inch long, 24-inch wide and 18-inch tall Ready-To-Finish (RTF) linear fire pit enclosure: the base structure for a long gas fire feature, delivered with its exterior panels already factory clad in 1\/2-inch PermaBase cement board, ready for the finish you choose. Firegear describes the cement board as impact resistant, moisture resistant and dimensionally stable, and states that it will not rot or swell when exposed to water. The enclosure supports up to 700 lb.\u003c\/p\u003e\n\u003cp\u003eTemplate lines on the top of the unit mark where to cut the opening for your burner, and Firegear includes a VENT-KIT-6X12 vent kit for the enclosure ventilation. It is the largest of Firegear's eight linear RTF sizes (42, 60, 84 and 108 inches long, each 24 or 34 inches wide). The 24-inch width is the narrower option beside the \u003ca href=\"\/products\/firegear-108-x-34-inch-linear-ready-to-finish-fire-pit-enclosure-rtf-l10834\"\u003e108 x 34-inch RTF-L10834\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan ahead: this is an enclosure only. The burner and pan, ignition system, gas connection and fire media are sold separately, and Firegear's RTF literature does not publish an opening size per burner, so send us the burner you have in mind and we will confirm the cut-out before you order. For a long linear burner, see the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003eFiregear Pro Series 60 x 10-inch linear burner system (LOF-6010PS506TPSI)\u003c\/a\u003e, the \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk\"\u003e80-inch Pro Series H-burner kit\u003c\/a\u003e or the \u003ca href=\"\/products\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n\"\u003eAWS all-weather ignition system\u003c\/a\u003e, and our \u003ca href=\"\/collections\/firegear\"\u003eFiregear collection\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e108 x 24 x 18-inch linear footprint:\u003c\/strong\u003e a long, low base for a linear gas fire feature on a patio or beside seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory clad in 1\/2-inch PermaBase cement board:\u003c\/strong\u003e the exterior panels arrive clad and ready for your finish, with a board Firegear rates as impact and moisture resistant and dimensionally stable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupports up to 700 lb:\u003c\/strong\u003e rated by Firegear to carry that load on the enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemplate lines on top:\u003c\/strong\u003e marked lines on the top of the unit guide the burner cut-out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVent kit included:\u003c\/strong\u003e a VENT-KIT-6X12 ships with the enclosure for the cross ventilation gas fire features need.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifetime coverage on construction:\u003c\/strong\u003e Firegear's product guide lists a lifetime warranty on construction and manufacturer defects for RTF enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eFiregear Outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eReady-To-Finish (RTF) enclosures, linear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eRTF-L10824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eReady-to-finish fire pit enclosure (no burner)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShape\u003c\/th\u003e\n\u003ctd\u003eLinear (rectangular)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e108 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e24 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e18 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExterior panels\u003c\/th\u003e\n\u003ctd\u003eFactory clad with 1\/2 in. PermaBase cement board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLoad rating\u003c\/th\u003e\n\u003ctd\u003eSupports up to 700 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner opening\u003c\/th\u003e\n\u003ctd\u003eCut on site along the template lines on the top; size it to the burner and pan you choose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVentilation\u003c\/th\u003e\n\u003ctd\u003eVENT-KIT-6X12 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBurner, ignition, media\u003c\/th\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOther linear sizes\u003c\/th\u003e\n\u003ctd\u003eRTF-L4224, RTF-L4234, RTF-L6024, RTF-L6034, RTF-L8424, RTF-L8434, RTF-L10824, RTF-L10834\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003eLifetime on construction and manufacturer defects (Firegear product guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003eRTF-L10824 linear enclosure, 108 x 24 x 18 in., exterior factory clad in 1\/2 in. PermaBase cement board, with template lines on top\u003c\/li\u003e\n\u003cli\u003eVent kit VENT-KIT-6X12\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eLinear burner and pan: Firegear Pro Series linear burner systems such as the \u003ca href=\"\/products\/firegear-pro-series-60-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-6010ps506tpsi-n\"\u003e60 x 10-inch LOF-6010PS506TPSI\u003c\/a\u003e or \u003ca href=\"\/products\/firegear-pro-series-48-x-10-inch-linear-flat-pan-natural-gas-fire-pit-burner-system-with-tpsi-ignition-lof-4810ps406tpsi-n\"\u003e48 x 10-inch LOF-4810PS406TPSI\u003c\/a\u003e, or the \u003ca href=\"\/products\/firegear-pro-series-80-x-6-75-inch-natural-gas-h-burner-kit-fg-psbr-h80-ngk\"\u003e80 x 6.75-inch H-burner kit FG-PSBR-H80\u003c\/a\u003e; ask us to confirm the fit and cut-out\u003c\/li\u003e\n\u003cli\u003eIgnition: \u003ca href=\"\/products\/firegear-290k-btu-natural-gas-30vdc-all-weather-valve-system-fg-aws30vdc-k-n\"\u003eAWS all-weather ignition system\u003c\/a\u003e (natural gas or propane), for fire features up to 290,000 Btu\/hr\u003c\/li\u003e\n\u003cli\u003eFire media, gas line, shut-off and electrical supply, and your exterior finish and top material\u003c\/li\u003e\n\u003cli\u003eMore burners and parts: \u003ca href=\"\/collections\/fire-pit-burners-components\"\u003efire pit burners and components\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhat Firegear publishes: the RTF literature gives the size, cladding, load rating, template lines and vent kit. It does not publish an assembly manual, a weight or opening sizes for the linear RTF units, so confirm the burner, cut-out and delivery with us before you order.\u003c\/li\u003e\n\u003cli\u003eBurner opening: cut the top along the template lines for the burner and pan you choose, and follow that burner's own instructions for pan depth, clearances to combustibles and media.\u003c\/li\u003e\n\u003cli\u003eVentilation: install the included VENT-KIT-6X12. Firegear's burner and ignition instructions call for at least 18 sq. in. of cross ventilation on each side of the enclosure, at the bottom of the feature for propane (propane is heavier than air), and state that missing ventilation voids the warranty.\u003c\/li\u003e\n\u003cli\u003eSite: Firegear's burner and ignition instructions require a non-combustible enclosure on a level, non-combustible surface, outdoor use only, a drain or water exit in above-ground features, and an LP tank kept outside the enclosure.\u003c\/li\u003e\n\u003cli\u003eGas and electrical: gas work by a qualified installer, service agency or gas supplier, to local codes or, without them, NFPA 54 and NFPA 70; plan the gas line, a manual shut-off and any GFI outlet the ignition system needs before you close up the enclosure.\u003c\/li\u003e\n\u003cli\u003eSize and handling: the unit is 108 inches long; plan the delivery path and the number of people needed to set it, since Firegear does not publish a shipping weight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eFiregear's product guide lists a lifetime warranty on construction and manufacturer defects for RTF enclosures. Firegear's current warranty document (products manufactured after 01\/01\/2026) lists construction and manufacturer defects at lifetime for consumers but does not name RTF enclosures separately, and any burner system you install carries its own warranty; ask us which term applies before you file.\u003c\/p\u003e\n\u003cp\u003eFiregear warrants its products to the end user against defects in material and workmanship. Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification voids the warranty. Full terms are on Firegear's warranty page.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/assets.spotix.com\/manuals\/Firegear\/Firegear-Product-Guide_2023.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2023, RTF enclosures, page 21 (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0667\/5357\/files\/Firegear-Product-Guide_2021.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear product guide 2021, linear enclosures (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.fliphtml5.com\/pdgn\/FG_Product-Guide_4-3-26\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear current product catalog (online)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cms.firegearoutdoors.com\/documents\/All-instructions\/7-Ignition-System-Components\/AWS-Ignition-Systems.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFiregear AWS ignition instructions: enclosure, ventilation and clearance rules (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/online.flipbuilder.com\/gearhead\/qwhm\/\" target=\"_blank\" rel=\"noopener\"\u003eFiregear warranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Firegear","offers":[{"title":"Default Title","offer_id":67634961744151,"sku":"RTF-L10824","price":3068.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/firegear-108-x-24-inch-linear-ready-to-finish-fire-pit-rtf-l10824-enclosure.jpg?v=1794342478"}],"url":"https:\/\/mnkgrills.com\/collections\/firegear.oembed?page=3","provider":"M\u0026K Grills","version":"1.0","type":"link"}