{"product_id":"bromic-tungsten-gas-heat-deflector","title":"Bromic Tungsten Gas Heat Deflector - 300 or 500 Series","description":"\u003ch2 id=\"description\" data-mnk-layout=\"1\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Bromic Tungsten Gas Heat Deflector is a dual-layer stainless steel shield that mounts to the back of a \u003ca href=\"\/products\/bromic-tungsten-smart-heat-gas-300-patio-heater\"\u003eTungsten Smart-Heat Gas 300\u003c\/a\u003e or \u003ca href=\"\/products\/bromic-tungsten-smart-heat-gas-500-patio-heater\"\u003eTungsten Smart-Heat Gas 500\u003c\/a\u003e heater. Bromic rates it to cut the clearance from the heater to a combustible surface above from 3 ft to 14 in. (35.6 cm), which is often what decides whether a mounted gas heater fits under a covered patio, pergola or low soffit. It also absorbs heat that would otherwise escape upward.\u003c\/p\u003e\n\u003cp\u003eChoose the 300 or 500 series above to match your heater. Only the clearance above the heater changes: the side clearance and the minimum mounting height in Bromic's clearance table (3 ft and 8 ft) stay the same. For the Platinum Gas range, see the \u003ca href=\"\/products\/bromic-platinum-gas-heat-deflector\"\u003ePlatinum Gas Heat Deflector\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003ePlan before ordering: the heater is not included and must be installed by authorized personnel. The heater runs from a 36 in. power cord with a 3-pin plug and has no on\/off switch, so it is controlled from the supply.\u003c\/p\u003e\n\u003cul class=\"mnk-glance\"\u003e\n\u003cli\u003e\n\u003cstrong class=\"mnk-glance__label\"\u003eClearance above:\u003c\/strong\u003e 14 in. with deflector, 3 ft without\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong class=\"mnk-glance__label\"\u003eMaterial:\u003c\/strong\u003e Dual-layer stainless steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong class=\"mnk-glance__label\"\u003eFits:\u003c\/strong\u003e Tungsten Smart-Heat Gas 300 or 500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong class=\"mnk-glance__label\"\u003eMounting:\u003c\/strong\u003e To the back of the heater, two screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"features\"\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e14 in. top clearance:\u003c\/strong\u003e down from 3 ft, so the heater can sit closer to a ceiling, beam or awning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-layer stainless steel:\u003c\/strong\u003e absorbs heat that would otherwise rise into the structure above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSized by series:\u003c\/strong\u003e separate 300 and 500 versions to match the 26,000 BTU and 43,000 BTU heaters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple fitting:\u003c\/strong\u003e the brackets go under the washers of two screws on the back of the heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEither fuel:\u003c\/strong\u003e the Tungsten Gas 300 and 500 come as separate propane and natural gas models; the deflector is chosen by series, not fuel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"specifications\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"mnk-specs\"\u003e\u003ctbody\u003e\n\u003ctr class=\"mnk-specs__group\"\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eIdentification\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBromic Heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eTungsten Smart-Heat Gas accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOur part numbers\u003c\/th\u003e\n\u003ctd\u003eBH3030011 (300 series), BH3030012 (500 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFits\u003c\/th\u003e\n\u003ctd\u003eTungsten Smart-Heat Gas 300 and 500, propane or natural gas (heater not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"mnk-specs__group\"\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eBuild and clearances\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eDual-layer stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eBack of the heater; brackets secured under the washers of two screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClearance above heater\u003c\/th\u003e\n\u003ctd\u003e14 in. (35.6 cm) with deflector; 3 ft without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSide clearance\u003c\/th\u003e\n\u003ctd\u003e3 ft (unchanged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum mounting height\u003c\/th\u003e\n\u003ctd\u003e8 ft (unchanged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReplacement fixings\u003c\/th\u003e\n\u003ctd\u003eDeflector screw set including arm, BH8080052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"mnk-specs__group\"\u003e\u003cth colspan=\"2\" scope=\"colgroup\"\u003eHeater it fits\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTungsten Gas 300\u003c\/th\u003e\n\u003ctd\u003e26,000 BTU, 19.3 in. wide, 33 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTungsten Gas 500\u003c\/th\u003e\n\u003ctd\u003e43,000 BTU, 25.4 in. wide, 44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGas supply\u003c\/th\u003e\n\u003ctd\u003eMax 14 in. W.C.; min 11 in. W.C. propane, 6 in. W.C. natural gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e110V, under 2 A; 36 in. cord with 3-pin plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cdiv class=\"mnk-kit\"\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"whats-included\"\u003eWhat's included\u003c\/h3\u003e\n\u003cul class=\"mnk-included\"\u003e\n\u003cli\u003eDual-layer stainless steel heat deflector, 300 or 500 series\u003c\/li\u003e\n\u003cli\u003eAssembly instructions in the deflector carton\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBromic does not publish a full packing list. Not included: the heater and the ceiling pole mount.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mnk-kit__col\"\u003e\n\u003ch3 id=\"sold-separately\"\u003eSold separately\u003c\/h3\u003e\n\u003cul class=\"mnk-optional\"\u003e\n\u003cli\u003eHeaters: \u003ca href=\"\/products\/bromic-tungsten-smart-heat-gas-300-patio-heater\"\u003eTungsten Smart-Heat Gas 300\u003c\/a\u003e, \u003ca href=\"\/products\/bromic-tungsten-smart-heat-gas-500-patio-heater\"\u003eTungsten Smart-Heat Gas 500\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/bromic-smart-heat-gas-ceiling-pole-mount\"\u003eSmart-Heat Gas Ceiling Pole Mount\u003c\/a\u003e, for hanging the heater from a ceiling or beam\u003c\/li\u003e\n\u003cli\u003eDeflector screw set including arm, BH8080052 (replacement fixings; ask us)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 id=\"installation\"\u003eInstallation planning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFitting the deflector:\u003c\/strong\u003e assemble it as shown in the instructions in the deflector carton, then mount it to the back of the heater: loosen the two screws, place the deflector brackets under the washers and retighten.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstaller:\u003c\/strong\u003e installation and service by authorized personnel only, to local codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances to combustibles:\u003c\/strong\u003e 14 in. above the heater with the deflector (3 ft without), 3 ft to the sides and an 8 ft minimum mounting height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting the heater:\u003c\/strong\u003e on the wall bracket the arm sits at 55 degrees and the heater can be set at 0, 10 or 20 degrees. Use M8 flush-head dynabolts in brick or masonry and screws at least 60 mm (2.4 in.) long in timber; ceiling fixings must also be at least 60 mm. A ceiling pole must be at 90 degrees to the ground, and Bromic recommends running the gas and power lines inside it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas hose:\u003c\/strong\u003e replacement hoses must be CSA approved with 3\/8 in. SAE flared ends; check the hose every year.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCare:\u003c\/strong\u003e Inspect and clean the control compartment, burner and air passages at least every six months, more often in harsh conditions, using compressed air at no more than 20 PSI. In salt air, check for corrosion more often. Use only non-combustible, non-corrosive cleaners, and do not add coatings: Bromic says additional coatings void the warranty. Wait 5 minutes after shutdown before relighting.\u003c\/p\u003e\n\u003ch3 id=\"warranty\"\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eBromic's warranty page does not list a separate term for the heat deflector. It covers Tungsten Gas heaters for 2 years, excluding maintenance items such as hoses and igniters, for the original owner only. Bromic supplies a replacement heater or part; the owner pays labor, removal and reinstallation, shipping both ways and other costs. Implied warranties are limited to one year. Claims start with the dealer who sold the product. Ask us to confirm the deflector's coverage before you order.\u003c\/p\u003e\n\u003ch3 id=\"manuals\"\u003eManuals and documents\u003c\/h3\u003e\n\u003cul class=\"mnk-docs\"\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/pim.bromic.com\/wp-content\/uploads\/2026\/05\/Manual-Tungsten-Gas-V2.3.pdf\" target=\"_blank\" rel=\"noopener\"\u003eTungsten Smart-Heat Gas installation, instruction and service manual, Version 2.3 USA\/Canada (PDF)\u003c\/a\u003e \u003cspan class=\"mnk-docs__meta\"\u003eDeflector fitting, clearances, mounting, care, parts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.bromic.com\/product\/tungsten-gas-heat-deflector\/\" target=\"_blank\" rel=\"noopener\"\u003eBromic Tungsten Gas Heat Deflector product page\u003c\/a\u003e \u003cspan class=\"mnk-docs__meta\"\u003eManufacturer description, 300 and 500 options\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.bromic.com\/warranty\/\" target=\"_blank\" rel=\"noopener\"\u003eBromic warranty terms\u003c\/a\u003e \u003cspan class=\"mnk-docs__meta\"\u003eWarranty periods by product line\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 id=\"legal\"\u003eLegal disclaimers and warnings\u003c\/h3\u003e\n\u003cp class=\"mnk-legal\"\u003eProduct packaging, owners' manuals, installation instructions, and\/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.\u003c\/p\u003e\n","brand":"Bromic Heating","offers":[{"title":"300 Series","offer_id":68167512195351,"sku":"BH3030011","price":301.0,"currency_code":"USD","in_stock":true},{"title":"500 Series","offer_id":68167512228119,"sku":"BH3030012","price":345.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1251\/8981\/files\/bromic-tungsten-gas-heat-deflector-300-or-500-series-bh3030011-bh3030012-deflector.jpg?v=1794343355","url":"https:\/\/mnkgrills.com\/products\/bromic-tungsten-gas-heat-deflector","provider":"M\u0026K Grills","version":"1.0","type":"link"}