Skip to product information
1 of 3

Lava Heat

Lava Heat Opus 32,000 BTU Patio Heater – Stainless Steel, Natural Gas, Assembled

Lava Heat Opus 32,000 BTU Patio Heater – Stainless Steel, Natural Gas, Assembled

Regular price $2,325.00
Regular price $2,795.00 Sale price $2,325.00
Sale Sold out
Free shipping Within the contiguous US
Quantity

Description

Lava Heat calls the Opus the flagship of its Ravello Lounge collection: a round column of flame with five-stage Clima-Comfort heat control by wireless remote. It is a round cabinet base on two wheels, with the flame running up a borosilicate glass tube inside a round protective guard.

This listing is the Stainless Steel finish, set up for natural gas, shipped assembled (Lava Heat SKU LHI-OPUS-NG-STAINLES).

Its certified input rating is 32,000 BTU/hr, and Lava Heat rates its heat radius at 8 ft all around the heater, about 201 sq. ft. Heat is set by wireless remote or at the control unit. Plan ahead: a natural gas model has to be connected to a fixed gas line by a qualified, licensed gas technician. Keep 36" clear of anything combustible on every side and above it.

  • Certified input: 32,000 BTU/hr
  • Heat radius: 8 ft, about 201 sq. ft.
  • Size: 82" H x 22" in diameter
  • Fuel: Natural gas
  • Control: Wireless remote, five settings
  • Warranty: Lifetime frame, 5 years parts and finish

Availability: Currently unavailable from the manufacturer. Contact M&K Grills for an updated availability estimate.

View full details

Features

  • 32,000 BTU/hr certified input: heat radiates 360 degrees from the glass flame tube, over a rated 8 ft radius (about 201 sq. ft.).
  • Measured comfort zone: on a 50°F evening, Lava Heat measured the air at about 74°F at 3 ft, about 66°F at 5 ft, about 60°F at 8 ft from the heater. It calls this its TruBTU standard: measured temperature at a distance rather than a theoretical output figure. Wind, humidity and nearby walls change what you feel.
  • Remote-controlled heat: digital ignition and five-stage Clima-Comfort control from the wireless remote. At the control unit, each press of POWER steps through the heat settings and off. A two-second press releases a safety lock before ignition.
  • Natural gas: runs continuously on a fixed gas line, with no cylinder to change. It ships with a 10 ft quick-connect hose.
  • Built for coastal air: a 430-grade stainless steel emitter, a marine-grade 6061-T6 aluminum chassis and a borosilicate glass flame tube. Lava Heat salt-spray tests the build for 500 hours to ASTM B117.
  • Safety shutoffs: a tilt switch shuts the heater off if it is knocked over, and a thermocouple flame-failure device cuts the gas if the flame goes out.
  • Removable glass tube: the borosilicate tube lifts out for cleaning soot or debris.
  • Residential and commercial use: outdoors only, with the same warranty terms either way.

Compare all patio and outdoor heaters or shop Lava Heat Italia heaters.

Specifications

Model
Brand Lava Heat Italia
Model The Opus (LHI-OPUS)
Collection Ravello Lounge
Lava Heat SKU LHI-OPUS-NG-STAINLES
UPC 721750415615
Finish Stainless Steel
Ships Assembled
Heat
Certified input 32,000 BTU/hr
Heat radius 8 ft, 360°, about 201 sq. ft.
Comfort zone (50°F evening) 74°F at 3 ft, 66°F at 5 ft, 60°F at 8 ft
Run time Continuous on a natural gas supply
Controls and safety
Ignition and control Digital one-touch ignition and five-stage Clima-Comfort heat control by wireless remote, or at the control unit
Batteries Two AAA batteries (remote)
Safety Tilt-switch auto shutoff, thermocouple flame-failure device
Size and build
Size 82" H x 22" in diameter
Weight 80 lb (Lava Heat spec sheet)
Wheels Two
Materials 430-grade stainless steel emitter, marine-grade 6061-T6 aluminum chassis and borosilicate glass flame tube
Gas
Fuel Natural gas, from a fixed gas line; ships with a 10 ft quick-connect hose
Natural gas pressure 4-7 in. W.C.; supply line at least 3/4" inside diameter
Installation
Clearance to combustibles 36" on every side and above
Use Outdoors only; residential and commercial
Certification CSA certified to ANSI Z83.26 / CSA 2.37; 500-hour ASTM B117 salt-spray tested
Carton 22.4 x 22.4 x 82 in.

What's included

  • The Opus heater, fully assembled
  • Wheel kit with two bolts and two M8 nuts, fitted during setup
  • Gas pressure regulator and a 10 ft quick-connect hose for the natural gas line
  • Wrench

You'll also need

  • A qualified, licensed gas technician to connect it, with an accessible manual shut-off valve and a supply line sized for every appliance on it (at least 3/4" inside diameter)
  • Two AAA batteries (remote), fitted before first use
  • A medium-blade Phillips screwdriver (not supplied)
  • Leak-check solution (not supplied): one part dishwashing liquid to three parts water

Installation planning

  • Outdoors only. Never use it in an enclosed space such as a home, garage, tent, camper or car: it produces carbon monoxide. Under cover, it can have walls on all sides with no roof, or a roof with no more than two side walls, or a roof with three side walls as long as at least 30% of the perimeter stays permanently open.
  • Clearance: 36" from anything combustible at the sides and above the top. Keep it away from windows, air intakes, sprinklers and other water sources, and from anywhere gasoline or other flammable liquids are stored.
  • Surface and weather: stand it on hard, level, non-combustible ground, and run it only when the wind is below 10 mph. It heats less efficiently below 40°F.
  • Setup time: about 10 minutes. Two people are recommended for any step where the heater has to be leaned.
  • Natural gas: installation must follow local codes or, where there are none, the National Fuel Gas Code ANSI Z223.1/NFPA 54 (CSA B149.1 in Canada). Never connect a gas line to the heater without the supplied pressure regulator.
  • Leak check: before the first lighting, brush leak-check solution on every gas connection and open the valve. Bubbles mean a leak. Repeat the test whenever a connection is loosened. Never use a flame to check for leaks.
  • Altitude: above 2,000 ft, installation must follow local codes, or ANSI Z223.1/NFPA 54 or CSA B149.1.

Using the heater

  • Lighting: open the gas supply, point the remote at the receiver (or use the control unit), press POWER for two seconds, release it and press again. On first use or with a new cylinder, light it from the control unit and allow at least a minute for air to purge from the gas line. If the display shows an error code, Lava Heat's control-panel troubleshooting guide explains each one.
  • First use: manufacturing oils burn off with some smoke and odor for about 30 minutes.
  • Relighting: if the pilot goes out, close all valves and wait at least five minutes before trying again.
  • After use: turn it off, close the gas supply, and don't touch, move or cover it for at least 45 minutes while it cools. Some discoloration of the emitter screen is normal.

Care and maintenance

  • Cleaning: warm soapy water on the outside. Never use flammable or corrosive cleaners, and keep the burner and pilot area dry. A gas control that has been under water must be replaced.
  • Glass tube: carbon deposits are a fire hazard. Remove the reflector and one protective guard, lift out the tube, wash and dry it, and refit it. Handle it with both hands and set it on something soft, never concrete or stone.
  • Spiders and insects: they can nest in the burner and orifices and make the heater unsafe. Clear the burner holes with a heavy-duty pipe cleaner or compressed air.
  • Salt air: check for corrosion often near the coast and repair it promptly.
  • Inspection: check the heater before each use, inspect the whole hose assembly at least once a year for cuts or wear, and have a qualified service person inspect it annually.
  • Storage: store it upright and sheltered from the weather, with the gas off. Remove the batteries if it will sit unused for a long time.

Warranty

Lava Heat Italia's limited warranty starts on the date of purchase shown on your receipt and covers residential and commercial installations on the same terms:

  • Frame and structure: lifetime
  • Parts: 5 years
  • Finish: 5 years
  • Burner and glass: 1 year
  • Gas hose and regulator assembly: 1 year

It covers parts only; labor and freight are not included. It is for the original purchaser, so keep your receipt. It does not cover damage caused by non-genuine parts, accident, alteration, misuse, abuse, or incorrect installation or removal, or consumable items and items damaged in service. Lava Heat handles warranty service, technical support and replacement parts directly (310-559-1700, customerservice@lavaheat.com). When ordering a part, quote the model (LHI-OPUS), the part letter from the setup or assembly guide, and the finish. Full terms are at lavaheat.com/warranty-and-product-care.

Manuals and documents