Features
- One upright, same drop: a single 24 in. pole for a cleaner line than the twin pole the heater ships with.
- Concealed cable: the heater cable runs up inside the pole and out into the roof cavity, so no wiring shows below the ceiling.
- Round ceiling cap: a round cap slides over the pole and covers the roof bracket for a clean finish at the ceiling.
- Quick head fitting: the heater bracket's two pre-fitted screws hook into a slot in the pole, then two more screws lock it.
- Double-coated steel in matte black: matches the Eclipse heater head and resists corrosion.
Specifications
| Identification | |
|---|---|
| Brand | Bromic Heating |
| Series | Eclipse Smart-Heat Electric accessory |
| Part number | BH3230002 |
| Type | Straight ceiling mount pole |
| Fits | Eclipse Smart-Heat Electric 2900W heater head, 240V (BH0920001-2) or 208V (BH0920003); head not included |
| Build | |
| Length | 24 in. |
| Material | Double-coated steel |
| Finish | Matte black |
| Ceiling fixing | Pendant mount roof bracket, fasteners in four opposing holes into structural supports (fasteners installer supplied) |
| Pole to bracket | 4 x M4 x 6 mm dome head screws |
| Cap to bracket | Round cap, 2 x M4 x 10 mm dome head screws |
| Head to pole | 2 pre-fitted plus 2 extra M4 x 6 mm dome head screws |
| Heater it carries | |
| Heater head | 27.6 x 27.6 x 4.4 in., 30 lb |
| Minimum height above floor | 8 ft (96 in.) |
| Clearance in front of head | 3.3 ft to floors, furniture, plants and heat-sensitive materials |
| Between heaters | 20 in., from the heater edge |
What's included
- Eclipse 24 in. straight pole, BH3230002
Bromic does not publish a separate packing list for the pole. In the heater's ceiling kit the manual lists the pole assembly with six M4 x 6 mm and two M4 x 10 mm dome head screws, and the steps use a pendant mount roof bracket and round cap; ask us to confirm which of these ship with the pole before ordering. Not included: the heater head and the ceiling fasteners.
Sold separately
- Eclipse Smart-Heat Electric 2900W heater, 240V (BH0920001-2) or 208V (BH0920003); ships with the 24 in. twin pole
- Affinity Smart-Heat Eclipse controller, 1 or 5 channel, for heat and light control with the app
- Ceiling mount pole screw set, BH8380009 (replacement fixings; ask us)
- Other poles: 8 in. straight (BH3230001), 24 in. twin (BH3230003), 24 in. curved (BH3230004), 48 in. straight (BH3230005), wall mount (BH3230006)
Installation planning
- Installer: a licensed electrical contractor or authorized technician, to local codes. Two people are needed; Bromic sets a safe lift of 35 lb per person, and the head weighs 30 lb.
- Roof bracket: fasten the pendant mount roof bracket to the ceiling with bolts sized for the surface (not included) in four opposing holes, into structural supports rather than ceiling panels alone. Bromic gives no load rating for the ceiling mount, so the installer chooses fasteners for the load.
- Pole and cap: attach the pole to the bracket with four M4 x 6 mm screws, then slide the round cap over the pole and fix it to the bracket with two M4 x 10 mm screws.
- Fitting the head: keep the cardboard on the head until it is mounted. Feed the cable up through the pole into the roof cavity and take up the slack, hook the heater bracket's two pre-fitted M4 screws into the slot in the pole, add two more M4 x 6 mm screws and tighten all four.
- Position: the head must be level (check with a spirit level), at least 8 ft above the floor, not directly above or in front of an electrical outlet and never facing the ceiling, with 3.3 ft clear in front and to heat-sensitive materials in every direction, and 20 in. between heaters.
- Weather and location: the heater is IP54; Bromic recommends a covered position out of the rain. Keep it away from pools, showers and other water and from areas where flammable liquids are used. Remove all packaging before switching on.
Care: Bromic asks for an inspection before use and a service at least once a year by a qualified technician. Switch off, disconnect power and let the heater cool for at least 2 hours before cleaning. Clean the pole and head with a soft, damp microfiber cloth and lukewarm water with mild dish soap, in gentle strokes in one direction, and let it air dry; do not use abrasive pads, harsh chemicals or a water spray, and do not paint any surface. Near the coast, clean every two weeks and after salt exposure. Do not use the heater if the head or pole is loose, and do not hang anything from the pole.
Warranty
Bromic's warranty page does not list a separate term for the Eclipse poles. The Eclipse Pendant heater is covered for 3 years, for the original owner only: Bromic supplies a replacement heater or part, and the owner pays labor, removal and reinstallation, shipping both ways and other costs. Implied warranties are limited to one year. Claims start with the dealer who sold the product. Ask us to confirm the pole's coverage before you order.
Manuals and documents
- Eclipse Smart-Heat Electric pendant instruction manual, Version 2 US, BMC-00693 (PDF)
- Eclipse Smart-Heat Electric cut sheet (PDF)
- Bromic Eclipse 24 Inch Straight Pole product page
- Bromic warranty terms
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.