



Features
- 39,800 BTU: radiant heat for an area of up to 215 sq ft, on propane or natural gas.
- Glass-ceramic screen: a tinted glass-ceramic face on a fully sealed 304 stainless steel body.
- Patented direct ignition, no pilot light: the heater lights itself whenever power is applied, so there is no standing pilot flame.
- Adjustable aim: the wall bracket sets the heater at 0, 10 or 20 degrees of tilt to point heat at the seating area.
- Optional heat deflector: cuts the clearance above the heater from 3 ft to 14 in.; Bromic recommends it when there is less than 1,100 mm (about 43 in.) above the heater or it is exposed to the elements.
- Smart-Heat controls: works with Affinity On/Off controllers and manual wall switches, and with building automation through an On/Off controller plus Bromic's Smart-Heat Link RS232 plug-in.
- IPX4 water rating: with the heater still installed under a protective cover.
Specifications
| Identification | |
|---|---|
| Brand | Bromic Heating |
| Series | Platinum Smart-Heat Gas |
| Model | 500 |
| Part numbers | BH0110004-1 propane, BH0110003-1 natural gas |
| Performance | |
| Gas consumption | 39,800 BTU (propane or natural gas) |
| Heat area | Up to 215 sq ft |
| Ignition | Patented direct ignition, no pilot light |
| Gas supply | |
| Propane line pressure | 11 in. W.C. minimum, 14 in. W.C. maximum |
| Natural gas line pressure | 6 in. W.C. minimum, 14 in. W.C. maximum |
| Manifold pressure | 10 in. W.C. propane, 5 in. W.C. natural gas |
| Orifice size | 0.85 mm propane, 1.3 mm natural gas |
| Gas inlet | 1/2 in. NPT female, at the control box |
| Replacement hose | CSA approved, 3/8 in. SAE flared ends |
| Electrical | |
| Supply | 110 V, under 2 A |
| Power cord | 36 in., grounded three-prong plug |
| Switch | None on the heater; controlled by its power supply |
| Size and build | |
| Width | 29.8 in. |
| Weight | 44 lb |
| Body | 304 stainless steel, fully sealed |
| Screen | Tinted glass-ceramic |
| Mounting | Wall bracket (included) or ceiling pole (sold separately) |
| Tilt | 0, 10 or 20 degrees |
| Clearances | |
| Minimum height above floor | 96 in. (8 ft) |
| Above the heater | 3 ft; 14 in. with the heat deflector |
| Sides | 3 ft |
| Compliance and controls | |
| Certification | Intertek 4009079 |
| Water rating | IPX4 |
| Controls | Affinity On/Off controller, manual wall switch; not dimmable |
| Warranty | 2 years, excluding hoses and igniters |
What's included
- Platinum Smart-Heat Gas 500 heater (BH0110004-1 or BH0110003-1)
- Wall bracket with control housing
Sold separately
- Platinum Gas heat deflector, 500 Series (BH3030002-1): cuts the top clearance to 14 in.
- Smart-Heat Gas ceiling pole mount: 9.69, 13.62, 17.56, 25.43, 33.31 or 41.18 in. (BH3030003 to BH3030008), for ceiling mounting
- Affinity Smart-Heat On/Off controller, 1, 2 or 5 channel (BH3130051, BH3130052, BH3130053), with wireless remote
- Affinity Smart-Heat expansion board (BH3130070)
- Manual wall switch kit, indoor or outdoor (BH3130071, BH3130072, BH3130081, BH3130082)
- Replacement parts listed in the manual for the 500 Series: glass (BH8080009), burner (BH8080030), Honeywell wiring harness and igniter (BH8080011), injector propane (BH8080016) or natural gas (BH8080017), Honeywell gas valve (BH8080014) and control (BH8080015), propane manifold (BH8080090) or natural gas manifold (BH8080037). Ask us for any of these.
Installation planning
- Installer: a licensed, authorized technician, following local codes or, without them, the National Fuel Gas Code ANSI Z223.1/NFPA 54 (US) or CSA B149.1 and B149.2 (Canada). Ground the heater electrically to NEC ANSI/NFPA 70 or CSA C22.1.
- Where it can go: outdoors, above ground, in open air with natural ventilation and no stagnant areas. It must not be installed or used in residential indoor areas, on recreational vehicles or boats, or where gasoline or other flammable liquids or vapors are stored.
- Enclosures: walls on all sides need at least one permanent opening at ground level; an overhead cover with no more than two walls is acceptable; with an overhead cover and more than two walls, at least 25% of the total wall area must be completely open and at least 30% of the remaining wall area open and unrestricted.
- Rain: install it under a protective cover; the heater must be protected from rain.
- Height and clearances: mount it at least 96 in. (8 ft) above the floor, with 3 ft to combustibles above and at the sides. With the heat deflector, the clearance above drops to 14 in. Bromic recommends the deflector when there is less than 1,100 mm (about 43 in.) above the heater or it is exposed to the elements.
- Heat-sensitive materials: plastic, vinyl siding, canvas, tri-ply and similar materials with low heat tolerance can degrade near the heater; protecting them is the installer's responsibility.
- Mounting: the wall arm faces down at 55 degrees and the heater tilts 0, 10 or 20 degrees. A ceiling pole must hang at 90 degrees to the ground.
- Gas: 1/2 in. NPT female inlet at the control box. Use propane on propane models and natural gas on natural gas models only. Leak-test every joint with soapy water, never a flame, and disconnect the heater from the supply piping during any pressure test above 1/2 psi. Above 2,000 ft, size the orifice to NFPA 54 or CSA B149.1.
- Power: 110 V, under 2 A, through a 36 in. cord with a grounded three-prong plug. There is no switch on the heater: it runs when power is applied, so plan an Affinity controller or a wall switch.
Operating notes: Turn on the gas, confirm the supply pressure, then switch on the power; the heater lights by itself with no pilot. If it does not light, switch the power off, wait 5 seconds and switch it on again; after 5 failed attempts, use Bromic's troubleshooting guide or call Bromic. The control needs a shutdown at least every 24 hours to run its self-check. After switching off, wait 5 minutes before relighting. Turn off the power to stop the heater, and the power and gas for longer shutdowns. Bromic advises against running the heater overnight.
Care: Bromic asks for a check before use and at least once a year by a qualified service person. Inspect and clean the control compartment, burners and air passages at least every 6 months, more often in dusty or harsh conditions; blow out the burners, manifold and injectors with compressed air at no more than 20 psi, with the heater off. Check the gas hose at least once a year and replace a worn hose only with a CSA-approved hose with 3/8 in. SAE flared ends. Near salt air, check for corrosion often. Do not apply coatings to the heater (Bromic says added coatings void the warranty) and do not clean it with combustible or corrosive products.
Warranty
Bromic covers the Platinum Smart-Heat Gas heater for 2 years from the date of purchase, excluding maintenance items, which Bromic lists as hoses and igniters. Coverage is for the original owner only: Bromic or its agent supplies a replacement heater or a replacement for the failed part. The owner pays for labor to service, remove and reinstall the heater, shipping to and from the distributor, handling and administrative charges, and any materials or permits needed to install the replacement. Implied warranties are limited to one year. Bromic also states that opening the control without authorization or applying added coatings voids its responsibility.
Start a claim with the dealer who sold you the heater; keep your proof of purchase.
Manuals and documents
- Platinum Smart-Heat Gas cut sheet (PDF)
- Platinum Smart-Heat Gas installation and instruction manual, US and Canada (PDF)
- Platinum and Tungsten Smart-Heat Gas troubleshooting guide (PDF)
- Bromic Platinum Smart-Heat Gas product page
- Bromic warranty terms
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov