





Features
- 2000W from one quartz tube element: the smallest Tungsten Electric output, on a single branch circuit at 8.3 A.
- Soft-glow infrared element: radiant heat with no harsh glare, directed with the adjustable brackets.
- Mirror-finish anodized reflector: Bromic's parabolic specular reflector directs the heat forward.
- Stainless body, IPX4: high-temperature, corrosion-resistant black coating with a honeycomb mesh front.
- Adjustable 6.5 in. brackets: wall or ceiling mounting, rotated to the angle you need and locked with a screw.
- Four mounting methods: wall, ceiling, tube suspension or flush ceiling recess, plus chain suspension.
- No ventilation needed: an electric heater has no combustion, so it suits covered and enclosed-roof patios.
Specifications
| Identification | |
|---|---|
| Brand | Bromic Heating |
| Series | Tungsten Smart-Heat Electric |
| Part number | BH0420030 (220-240V, black) |
| Other versions | 208V and 277V versions are in Bromic's manual (ask us) |
| Performance | |
| Heat output | 2000W |
| Elements | 1 quartz tube element |
| Reflector | Mirror-finish anodized (parabolic specular) |
| Control | Affinity On/Off, Affinity Dimmer, manual wall switch, or hard-wired |
| Electrical | |
| Supply | 220-240V |
| Current | 8.3 A |
| Connection | Hard-wired, grounded; one branch circuit, leads L1/N1 |
| Supply wire | Copper or aluminum, rated 90°C (194°F) minimum |
| Junction box entry | 22 mm (0.86 in.) to standard 1/2 in. weatherproof conduit fitting; IPX4 cord grip rated 90°C |
| Size and build | |
| Dimensions | 44 x 8.5 x 3.5 in. |
| Weight | 19.8 lb |
| Mounting brackets | 6.5 in., two supplied |
| Body | Stainless steel, high-temperature corrosion-resistant coating |
| Front | Honeycomb mesh |
| Color | Black |
| Clearances | |
| Minimum mounting height | Heater surface 96 in. above the floor (required for cETL); cut sheet: wall 72 in., ceiling 96 in. |
| In front of the heater | 3 ft (900 mm) clear |
| Combustible materials | 3 ft from the front; keep them clear of the sides and rear |
| Between heaters | 20 in. from heater edge |
| Heater face to ceiling, tube suspension | 9.84 in. minimum |
| Ceiling recess box length | 46 in. minimum |
| Basis | Surface temperature of 117°F above room temperature |
| Compliance and use | |
| Listing | Intertek ETL / cETL 4005951 |
| Water ingress | IPX4 |
| Use | Indoor and covered outdoor spot heating, residential or commercial |
| Warranty | 2 years heater, 7 years heating element |
What's included
- Tungsten Smart-Heat Electric 2000W heater with front cover
- One tube element
- Two 6.5 in. wall or ceiling mounting brackets
- Mounting hardware
- Installation, instruction and service manual
Not included: fasteners into the wall or ceiling, controls, chains, and recess or suspension kits.
Sold separately
- Tungsten Electric ceiling recess kit, 2000W/4000W size: BH8180010 black; mounts the heater flush in a ceiling box
- Tungsten Electric tube suspension kit, 3 ft: BH8180012 black; hangs the heater 39.39 in. below the ceiling, angled 15, 30 or 45 degrees
- Affinity Smart-Heat On/Off controller, 1, 2 or 5 channel (BH3130051/52/53): full-power control, 6000W per channel
- Affinity Smart-Heat Dimmer controller, 1, 2 or 5 channel (BH3130061/62/63): adjustable heat, 6000W per channel
- Affinity Smart-Heat expansion board (BH3130070): BMS or Ethernet connection for 1 and 2 channel Affinity controllers
- Manual wall switch heater kit: single switch for a one-element heater
- Replacement parts: element 240V BH8180001; front cover BH8180003 black; element end cover set BH8180005; junction box cover and seal set BH8180007; mounting bracket sets BH8180008 short, BH8180009 long (ask us)
Installation planning
- Installer: permanent installation and hard-wiring by a licensed, authorized person to local electrical and building codes, on a properly grounded supply that matches the rating label. Disconnect power before installing or servicing, and build a means of disconnection into the fixed wiring.
- Wiring: one branch circuit only, leads labeled L1 and N1; Bromic's diagram shows a standard wall switch for the 2000W and 3000W models. With an Affinity controller, follow the Affinity manual. Use 90°C-rated wire, an IPX4 cord grip rated 90°C and IPX4 conduit fittings outdoors; the ground screw is in the end of the junction box.
- Orientation: the tube element must be horizontal. Vertical mounting makes the element sag and burn out early, and voids the warranty.
- Brackets: fasten the brackets to the wall or ceiling (fasteners not supplied), lock the heater on with an M5 x 10 screw and nut, rotate it to the angle you want and lock it with a self-tapping screw. Short brackets (sold separately) bring the heater closer to a wall.
- Tube or chain suspension: the 3 ft tubes put the heater surface 39.39 in. below the ceiling and can be cut shorter (drill new holes); keep at least 9.84 in. from the heater face to the ceiling and 96 in. to the floor. For chains, the installer sizes them for the heater's 19.8 lb and fixes them with crimped S-hooks.
- Ceiling recess: the installer builds a ceiling box at least 46 in. long from cement board or similar and lines joists above it with fireproof insulation; the electrical connection is made outside the box.
- Clearances: 3 ft clear in front, combustibles kept 3 ft from the front and clear of the sides and rear (Bromic includes nearby ceiling fans), and 20 in. between heaters. Protect nearby low-heat materials such as vinyl siding, canvas or plastic.
- Placement limits: do not aim the heater at the ceiling or mount it directly below or in front of a wall power socket. Not for bathrooms, laundries, wardrobes, RVs or boats, not near a bathtub, shower or pool (switches and controls must be out of reach of anyone using them), and not where gasoline, paint or other flammable liquids or vapors are used or stored.
- Weather: outdoors, mount it with the face angled down and under cover where possible. Bromic advises against direct exposure to rain, snow or salt mist.
Care: Inspect the heater before use and have a qualified, licensed person check it at least once a year; servicing is done with the power disconnected. Clean the housing regularly with a soft, damp cloth, every two weeks in coastal areas where salt air can rust metal. Keep dust off the reflector and element, because buildup causes overheating and early element failure: turn the heater off, wait at least 2 hours, then wipe them with a soft, dry cloth. If the heat seems too low, Bromic's checklist points to a heater that is too small, mounted too high or far, or on the wrong voltage; a hot spot on a tube usually means the heater is not level or the tube has grease or moisture on it. Stop using the heater if you suspect damage, and have a licensed person replace a damaged supply cord. Bromic says it is not designed for continuous overnight use; switch it off or use a timer or controls.
Warranty
Bromic covers the Tungsten Smart-Heat Electric heater for 2 years and its heating element for 7 years. Coverage is for the original owner only: Bromic or its agent supplies a replacement heater or a replacement for the failed part. The owner pays for labor to service, remove and reinstall the heater, shipping to and from the distributor, handling and administrative charges, and any materials or permits needed to install the replacement. Implied warranties are limited to one year.
The manual states that mounting the heater vertically, or installing the cord grip or conduit fittings incorrectly, voids the warranty. Start a claim with the dealer who sold you the heater; keep your proof of purchase.
Manuals and documents
- Tungsten Smart-Heat Electric installation, instruction and service manual, US, 1125_v1 (PDF)
- Tungsten Smart-Heat Electric product cut sheet (PDF)
- Bromic Tungsten Smart-Heat Electric product page
- Bromic warranty terms
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov