

Features
- 175,000 Btu/hr on propane: the same rating as Firegear's 25 and 34-inch square and 26, 29, 32 and 34-inch round flat-pan systems with the 21-inch burner, so the 30-inch disc gives that output in a mid-size square pit.
- 21-inch brass Spur burner, four injectors per leg: individual brass injectors spread the flame across the burner instead of feeding it from one orifice.
- TPSI safety pilot: a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.
- Gas train in the box: Copreci high-capacity valve, 46-inch 1/2-inch stainless flex line, propane pilot assembly with 48-inch leads, TPSI faceplate and fittings.
- Flat 30-inch stainless disc: it covers an opening of at least 28 inches and lifts off, so the burner and pilot can be reached for the annual inspection Firegear calls for.
Specifications
| Brand | Firegear Outdoors |
|---|---|
| Series | Pro Series square burner systems, flat pan, Spur burner, TPSI |
| Model | FPB-30SFPSBR21TPSI-P (propane) |
| Type | Square fire pit burner system: flat pan (disc), burner and ignition |
| Pan | 30 in. square flat stainless disc (PAN-SS30SF), 1/16 in. listed disc depth |
| Enclosure opening | 28 in. minimum; do not exceed the 30 in. disc size (Firegear Table 1) |
| Burner | 21 in. Pro Series brass Spur burner, four injectors per leg (propane); burner part FG-PSBR-BS21-LP |
| Injector size | #68 (0.031 in.), propane |
| Output | 175,000 Btu/hr (51.28 kW) |
| Fuel | Propane only; natural gas and propane are separate models |
| Inlet gas pressure | Propane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC |
| Ignition | TPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery) |
| Gas valve | Copreci high capacity valve (68001599) with control knob CN-ALHC |
| Gas connection | 1/2 in. stainless flex line, 46 in. (T200-9898-46), to a 1/2 in. male flare fitting on your shut-off valve |
| Pilot leads | 48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them |
| Enclosure ventilation | At least 18 sq. in. of cross ventilation per side |
| Clearances to combustibles | 8 in. ground level, 36 in. side wall, 120 in. ceiling, 18 in. floor; not for an enclosed space |
| Use | Outdoor use only |
| Installation codes | Local codes; otherwise ANSI Z223.1/NFPA 54 (U.S.) or CSA B149.1 (Canada) |
| Fire media | 1 to 2 in. lava rock or media, sold separately |
| Not included | Enclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us) |
| Warranty | Firegear limited warranty; see Warranty below |
What's included
- 30 in. square flat stainless disc (PAN-SS30SF) with 21 in. Pro Series propane Spur burner (FG-PSBR-BS21-LP)
- Hardware bag with mounting plate screws, injector hoods, Piezo wires and flex connector
- Copreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504), control knob (CN-ALHC) and knob label
- 1/2 in. stainless flex gas line, 46 in. (T200-9898-46)
- Propane pilot assembly with 48 in. leads (PES-LP495) and 48 in. corrugated pilot tube (90-9898-48)
- Manual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab (GROUNDTAB)
- TPSI faceplate / control panel (78188) and 5-1/2 x 3 in. TPSI cover plate (78116)
- Fittings: U1-8D-S flare to MIP, 49-88 elbow, U3-8D-S, 113SS4-D2 nipple, plus stainless screws, nuts and washers
- Firegear installation and operating instructions (Flat Pan Spur TPSI, Rev. C)
Sold separately
- A non-combustible square enclosure; Firegear's ready-to-finish square enclosures include the 42 x 42 in. RTF-S42, 48 x 48 in. RTF-S48 and 60 x 60 in. RTF-S60 (ask us to confirm the cut-out for a 28 to 30 in. opening before you order)
- Manual gas shut-off valve with a 1/2 in. male flare outlet (not supplied)
- Vents giving 18 sq. in. per side: Firegear VENT-KIT-6X12, PAVER-VENT-4-LNTS, PAVER-VENT-6-LNTS or PAVER-VENT-6X12SS
- Firegear FlexFrame installation brackets, which Firegear highly recommends for every installation
- E-Stop 1-hour timer shut-off valve ESTOP1-0H
- Fire media: 1 to 2 in. lava rock, lava stones or fire glass
Installation planning
- Who installs: gas installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.
- Enclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Do not set it on grass, dirt or rocks. Cut the opening to at least 28 inches and no larger than the 30-inch disc size. Firegear highly recommends a FlexFrame kit for every installation. Keep the disc removable for service, and do not let the coping or cap overlap the disc unless it lifts off easily.
- Ventilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two Firegear 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation will void the warranty.
- Clearances to combustibles: 8 in. at ground level, 36 in. to a side wall, 120 in. to a combustible ceiling and 18 in. to a combustible floor, kept on all sides, top and bottom. These clearances are not for an enclosed space.
- Gas supply: install a manual shut-off valve (not supplied) with a 1/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3/4 in. black iron pipe for the supply, says to consult NFPA 54 for runs over 20 ft on units above 100,000 Btu, and adds about 5 ft of pipe per fitting; at 175,000 Btu/hr have a licensed plumber or gas fitter size the line. Plan the propane supply and regulator with your gas supplier: Firegear lists an LP regulator with 32 in. hose (FG-32LPHRK) as a replacement part but does not list it in the carton contents or size the tank, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests at or below 1/2 psig and leak-test every connection with soapy water before use.
- Media: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed by hand, not poured from the bag or packed tight, with the dust removed. Cover the burner completely but no more than 1 in. above the ports, keep media off and under the pilot screen cover, keep the top of the screen hood open and never block the injectors. Avoid materials that hold moisture.
- Weather: gusts of 25 to 30 mph or more can cause pilot outages. After heavy rain or high humidity, let the unit dry, then light it, step back and watch it for at least 30 minutes until any popping stops.
- Lighting: hold the red spark button and listen for the spark in the pilot hood, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again; if there is no spark, shut off the gas and check the igniter gap and battery. Do not stand over the unit while lighting or running it.
Care: Have a qualified service person inspect and clean the system before first use and at least once a year. Inspect the gas connection before each use and leak-test it with soapy water. Keep the control compartment, burner and air passages clean and check the burner orifices for spider webs. If water collects in the fire pit, remove the media, clear the weep holes and refill with clean, dust-free media. Use a ventilated cover when the fire pit is not in use and remove any combustible cover before lighting. Replace faulty parts only with approved Firegear parts. Gold or brown discoloration of the stainless steel is normal.
Warranty
Firegear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and disc before you file.
Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, damage from combustible items left on the unit, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.
Manuals and documents
- Firegear FPB Pro Spur Burners, Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)
- Firegear Square Pro Burner Systems product page
- Firegear installation instructions library
- Firegear current product catalog (online)
- Firegear warranty
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product (benzene and carbon monoxide from the fuel and its combustion). For more information go to www.P65Warnings.ca.gov.