Skip to product information
1 of 2

Firegear

Firegear Propane All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-P

Firegear Propane All Weather Ignition System for Single Fire Feature - FG-AWS30VDC-GOEK-P

Regular price $3,499.00
Regular price Sale price $3,499.00
Sale Sold out
Free shipping Within the contiguous US
Quantity

Order before noon Pacific Time for same-day shipping.*

Estimated delivery within the contiguous US: 2–3 business days after shipping.

*Monday–Friday, excluding holidays.

Shipping details

Orders placed before 12:00 p.m. Pacific Time Monday–Friday ship the same day, excluding holidays. Orders placed after the cutoff, on weekends, or on holidays ship the next business day.

Delivery within the contiguous US typically takes 2–3 business days after shipping. Saturdays, Sundays, and holidays do not count toward this estimate.

Orders with a subtotal over $199.99 before tax qualify for free base shipping to US destinations. Orders with a subtotal of $199.99 or less before tax have a $29.99 base shipping charge per order.

Additional shipping charges may apply to Alaska, Hawaii, and US territories. We will notify you of any additional charge on a case-by-case basis before shipping. See our shipping policy for details and delivery estimates for these destinations.

View our shipping policy

Ask an Expert

Buy with confidence. Talk to a grill expert today.

Hours

Sales & Support Hours (Pacific)

Sales
Mon–Fri 7am–9pm · Sat 8:30am–5pm · Sun 9:30am–6pm
Support
Mon–Fri 8am–5pm · Sat 8:30am–5pm · Sun 9:30am–6pm

Description

This is Firegear's AWS (All Weather System) Single Fire Feature ignition kit for propane, model FG-AWS30VDC-GOEK-P: a 30-volt DC electronic valve and pilot system that lights and monitors the burner in one custom-built gas fire pit or fire feature. It ships with its own GOE-30VDC power supply, which plugs into a 120VAC GFI outlet and converts it to 30VDC for the valve, so a single feature needs no separate power supply. Firegear's product guide notes that all of the kit's components can be housed underneath the burner.

The system is rated for up to 290,000 Btu/hr at the burner, and Firegear's propane orifice table runs from 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12). A hot surface igniter heats the pilot, the pilot valve opens with a click, and the burner should light within about 20 seconds; a thermopile proves the flame, and the controller tries three relights before it locks out. You turn it on and off with the weatherproof rocker switch on the faceplate, or add an optional remote, wall switch, timer or emergency stop.

Plan ahead: this kit is for one fire feature only, installed at least 10 feet from a pool or spa. For two to four features, or any feature within 5 feet of a pool or spa, Firegear specifies the AWS multiple fire feature kit for propane (FG-AWS30VDC-K-P) with the FG-AWS-PS-30V320 pool-certified power supply. Propane needs its own planning: Firegear requires ventilation and drainage at the bottom of the feature, an LP tank of at least 100 lb kept outside the enclosure, and a 3-inch nipple in the burner ahead of the propane orifice. Order the fuel you will use: Firegear states that only natural gas models can be converted to propane. The pan, burner and main burner orifice are not included; see our fire pit burners and components. The natural gas version is the FG-AWS30VDC-GOEK-N.

View full details

Features

  • 30VDC all-weather electronic ignition: low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.
  • Power supply included: the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.
  • Up to 290,000 Btu/hr per fire feature: sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.
  • Set up for propane: propane pilot orifice (FG-PBO-LP) on the pilot, with Firegear's LP orifice table (OAS-LP41 to OAS-LP12) for sizing the main burner.
  • Automatic relight and lockout: the controller makes three relight attempts, then locks out until it is switched off and on again.
  • Works with your choice of switch: faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).
  • Certified for the USA and Canada: tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.

Specifications

Brand Firegear Outdoors
Series AWS (All Weather Electronic Ignition System)
Model FG-AWS30VDC-GOEK-P (propane)
Type Single fire feature ignition kit (power supply included)
Use One fire feature, installed 10 ft or more from a pool or spa
Maximum input 290,000 Btu/hr per fire feature; propane orifice table 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12)
Linear burner length 24 in. to 14 ft per valve (longer systems: custom quote)
Fuel Propane (LP). Models are ordered as natural gas or propane; Firegear states only natural gas models can be converted to propane
Inlet gas pressure, propane Min 8.0" WC (1/4 psi), normal 11.0" WC (3/8 psi), max 14.0" WC (1/2 psi), low-pressure LP after regulation
LP supply Tank of 100 lb capacity or more, located outside the fire pit enclosure
Main burner orifice Not included; LP orifices have vent holes at the base, and propane installs need a 3" nipple in the burner before the orifice
Gas connection 1/2" flare x 1/2" MIP fitting (U1-8D-S) at the valve inlet; a 3/4" burner needs a reducer; 46" flex connector from the valve box to the manual key valve
Ignition Hot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with LP pilot orifice (FG-PBO-LP) and thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout
Valve power 30VDC from the power supply; never connect 120VAC directly to the valve wires
Power supply GOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations
Wiring 12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors
Pilot placement Pilot assembly within 22" of the valve box (24" pilot gas lines)
Manual key valve Needs a 1-1/4" round clearance hole in the non-combustible enclosure wall
Elevation Listed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice
Certification Lab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014)
Not included Pan, burner, main burner orifice, LP tank and regulator

What's included

  • 30VDC AWS gas valve with ignition control box (FG-ICB)
  • Pilot burner assembly (FG-PBA) set up for propane, with heat shield (FG-HEATSHIELD)
  • Power wire to the valve (10626)
  • GOE-30VDC power supply for one fire feature
  • Key valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)
  • Hardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3/4" screws, brass nut, two 8-18 x 1/2" screws, 1/2" NPT x 1/2" flare fitting
  • Firegear AWS installation and operating instructions

Sold separately

  • A fire pit pan and burner, and the propane main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our fire pit burners and components or the Firegear collection
  • On/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order
  • Enclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS / PAVER-VENT-6LNTS (each gives 18 sq. in. per side); for propane, vents go at the bottom of the feature
  • Fire media: lava rock (1 to 2 in.) or fire glass (1/2 to 3/4 in.)
  • Replacement LP pilot orifice FG-PBO-LP

Installation planning

  • Who installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).
  • Enclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1/4" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.
  • Propane ventilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure, at the bottom of the feature. Propane is heavier than air and settles, so Firegear requires drainage and ventilation at the bottom and a vent or drain line so gas cannot collect. Firegear states that failure to provide proper ventilation voids the warranty.
  • LP tank: use a tank of at least 100 lb capacity, keep every LP tank outside the enclosure, and do not store an LP cylinder that is not connected near this or any other appliance.
  • Clearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36" side wall, 96" ceiling, 18" floor; 150,000 to 250,000 Btu needs a 120" ceiling. Pan depth 2-1/2" to 3". Keep the burner ports facing up, the burner at least 3" inside the pan or bowl and at least 6" from its edge, and mount the pilot within 22" of the valve box using the supplied template.
  • Gas: size the supply pipe with Firegear's LP pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1/2 psi. Install a 3" nipple in the burner before the LP orifice, and never run the kit without a main burner orifice. If the wrong pilot orifice is fitted, the pilot will not light.
  • Electrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.
  • Media: lava rock at least 1 to 2 in. or glass at least 1/2 to 3/4 in., no more than 1" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.
  • Lighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.

Care: Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.

Warranty

Firegear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01/01/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.

Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.

Manuals and documents