Features
- 30VDC all-weather electronic ignition: low-voltage valve, hot surface igniter and thermopile light and monitor the burner without a match or spark lighter.
- Power supply included: the GOE-30VDC supply plugs into a 120VAC GFI outlet and fits inside the enclosure, so one fire feature is a single-kit install.
- Up to 290,000 Btu/hr per fire feature: sized for large custom fire pits; one valve handles linear burners from 24 inches to 14 feet.
- Set up for propane: propane pilot orifice (FG-PBO-LP) on the pilot, with Firegear's LP orifice table (OAS-LP41 to OAS-LP12) for sizing the main burner.
- Automatic relight and lockout: the controller makes three relight attempts, then locks out until it is switched off and on again.
- Works with your choice of switch: faceplate rocker switch, or optional remote (FG-1420-AOD), wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) or emergency stop (FG-EMER-STOP).
- Certified for the USA and Canada: tested to ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014), per the installation instructions.
Specifications
| Brand | Firegear Outdoors |
|---|---|
| Series | AWS (All Weather Electronic Ignition System) |
| Model | FG-AWS30VDC-GOEK-P (propane) |
| Type | Single fire feature ignition kit (power supply included) |
| Use | One fire feature, installed 10 ft or more from a pool or spa |
| Maximum input | 290,000 Btu/hr per fire feature; propane orifice table 75,000 Btu (OAS-LP41) to 250,000 Btu (OAS-LP12) |
| Linear burner length | 24 in. to 14 ft per valve (longer systems: custom quote) |
| Fuel | Propane (LP). Models are ordered as natural gas or propane; Firegear states only natural gas models can be converted to propane |
| Inlet gas pressure, propane | Min 8.0" WC (1/4 psi), normal 11.0" WC (3/8 psi), max 14.0" WC (1/2 psi), low-pressure LP after regulation |
| LP supply | Tank of 100 lb capacity or more, located outside the fire pit enclosure |
| Main burner orifice | Not included; LP orifices have vent holes at the base, and propane installs need a 3" nipple in the burner before the orifice |
| Gas connection | 1/2" flare x 1/2" MIP fitting (U1-8D-S) at the valve inlet; a 3/4" burner needs a reducer; 46" flex connector from the valve box to the manual key valve |
| Ignition | Hot surface igniter (FG-HSI) and pilot burner assembly (FG-PBA) with LP pilot orifice (FG-PBO-LP) and thermopile (FG-TP); ignition within about 20 seconds; three relights, then lockout |
| Valve power | 30VDC from the power supply; never connect 120VAC directly to the valve wires |
| Power supply | GOE-30VDC included: 3 ft cord to a 120VAC GFI outlet, 3 ft leads to the valve; outdoor rated for damp and dry locations |
| Wiring | 12 AWG or heavier, solid or stranded; dielectric grease on wire nuts and connectors |
| Pilot placement | Pilot assembly within 22" of the valve box (24" pilot gas lines) |
| Manual key valve | Needs a 1-1/4" round clearance hole in the non-combustible enclosure wall |
| Elevation | Listed for 0 to 4,500 ft; above that, reduce input 4% per 1,000 ft with a smaller orifice |
| Certification | Lab Test, USA and Canada: ANSI Z21.97-2014 and CSA C22.2 No. 3-M1998 (R2014) |
| Not included | Pan, burner, main burner orifice, LP tank and regulator |
What's included
- 30VDC AWS gas valve with ignition control box (FG-ICB)
- Pilot burner assembly (FG-PBA) set up for propane, with heat shield (FG-HEATSHIELD)
- Power wire to the valve (10626)
- GOE-30VDC power supply for one fire feature
- Key valve and rocker switch mounting plate (faceplate, 78130) with weatherproof rocker switch (WP-SWITCH)
- Hardware bag (FG-AWS-HARDWARE-BAG): AWS plate, four 10-24 x 3/4" screws, brass nut, two 8-18 x 1/2" screws, 1/2" NPT x 1/2" flare fitting
- Firegear AWS installation and operating instructions
Sold separately
- A fire pit pan and burner, and the propane main burner orifice sized for your Btu (Firegear OAS-LP orifices): browse our fire pit burners and components or the Firegear collection
- On/off remote control with 110V receiver (FG-1420-AOD), 120VAC wired wall switch (FG-WS-OD), 2-hour timer (FG-TIMER-2HR) and electronic emergency stop (FG-EMER-STOP); ask us to order
- Enclosure ventilation: VENT-KIT-6X12SS or PAVER-VENT-4LNTS / PAVER-VENT-6LNTS (each gives 18 sq. in. per side); for propane, vents go at the bottom of the feature
- Fire media: lava rock (1 to 2 in.) or fire glass (1/2 to 3/4 in.)
- Replacement LP pilot orifice FG-PBO-LP
Installation planning
- Who installs: Firegear says gas work should be done by a qualified installer, service agency or gas supplier, and repairs by a qualified service person; in pool and multi-feature installs the gas line must be configured by a licensed plumber. Install to local codes, or without them to NFPA 54 (National Fuel Gas Code) and NFPA 70 (National Electrical Code).
- Enclosure: install the kit with a pan, burner and orifice in a non-combustible enclosure on a level, non-combustible surface; outdoor use only, never in an enclosed space. Pans must be removable for service (304 stainless, 16 gauge or heavier recommended; no perforated metal or stiff screen), with 1/4" drain holes, and above-ground features need a drain or water exit. Below-ground installation is not approved.
- Propane ventilation: provide at least 18 sq. in. of cross ventilation on each side of the enclosure, at the bottom of the feature. Propane is heavier than air and settles, so Firegear requires drainage and ventilation at the bottom and a vent or drain line so gas cannot collect. Firegear states that failure to provide proper ventilation voids the warranty.
- LP tank: use a tank of at least 100 lb capacity, keep every LP tank outside the enclosure, and do not store an LP cylinder that is not connected near this or any other appliance.
- Clearances to combustibles (Firegear table, 75,000 to 150,000 Btu): 36" side wall, 96" ceiling, 18" floor; 150,000 to 250,000 Btu needs a 120" ceiling. Pan depth 2-1/2" to 3". Keep the burner ports facing up, the burner at least 3" inside the pan or bowl and at least 6" from its edge, and mount the pilot within 22" of the valve box using the supplied template.
- Gas: size the supply pipe with Firegear's LP pipe-sizing table for your run length and Btu (add about 5 ft per fitting), install a manual shut-off within 6 ft of the feature, purge new lines, and bond the gas line at each fire feature (NEC 680.26(B)). Isolate the appliance for pressure tests above 1/2 psi. Install a 3" nipple in the burner before the LP orifice, and never run the kit without a main burner orifice. If the wrong pilot orifice is fitted, the pilot will not light.
- Electrical: the power supply needs a 120VAC GFI outlet in a weatherproof box, with the supplied weatherproof box mounted within 6 ft of the GFI box. The GOE-30VDC supply goes inside the enclosure because of its 3 ft leads, and is for one feature at least 10 ft from water.
- Media: lava rock at least 1 to 2 in. or glass at least 1/2 to 3/4 in., no more than 1" deep over the burner ports, and keep the pilot hood clear. Above 4,500 ft, reduce input 4% per 1,000 ft.
- Lighting: open the manual key valve and switch ON; the igniter glows in about 10 seconds, then the pilot valve clicks open. If it has not lit within 20 seconds, switch OFF, wait 5 minutes and try again. Do not stand over the feature while it lights, never leave it unattended, and close the key valve when it will not be used for a while. Wet media can crack or pop: cover the feature when not in use and allow at least 30 minutes after lighting in wet or humid weather.
Care: Have a qualified person inspect the system before use and at least once a year. Keep the control compartment, burners and air passages clean, and inspect the fuel connection before each use. Store it indoors only when it is disconnected from the gas supply. Do not use it if any part has been under water; have a qualified technician replace any affected parts.
Warranty
Firegear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user, for products manufactured after 01/01/2026. Firegear's warranty table lists AWS electronic ignition systems at 3 years (consumer) and 1 year (commercial), and lists gas valves, pilot assemblies, power supplies and controls at 5 years (consumer) and 2 years (commercial); ask us which term applies to your part before you file.
Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts at no charge (a returned part needs an RMA, valid for 30 days); out-of-box claims must be made within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any modification, or installation without the required ventilation, voids the warranty. Full terms are on Firegear's warranty page.
Manuals and documents
- Firegear AWS installation and operating instructions, single and multiple fire feature kits, Rev. C (PDF)
- Firegear AWS installation and operating instructions, FG-AWS30VDC-K kits, Rev. D (PDF)
- Firegear product guide 2021, AWS a la carte systems (PDF)
- Firegear current product catalog (online)
- Firegear AWS Single Fire Feature Ignition System product page
- Firegear warranty
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: this product can expose you to chemicals including benzene and carbon monoxide, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.