Features
- 33,000 BTU propane burner: WPPO says it takes the Traditional 25 oven up to 700°F
- Hose and regulator included: connects to a standard 20 lb LP cylinder
- Made for the Traditional 25 Dual Fueled oven: a spare or replacement burner for the WKE-04WG ovens
- Push-and-turn ignition: the control knob sparks the burner on LOW, then turns up to HI
- 13" x 9" x 4" burner: WPPO's listed size, for checking against the burner you are replacing
Specifications
| Brand | WPPO (WPPO LLC) |
|---|---|
| Series | Traditional 25" Dual Fueled oven parts |
| Model | WKEA-04-GAS (Gas Burner for Dual Fueled Outdoor Oven) |
| Type | Replacement gas burner |
| Fits | WPPO Traditional 25" Dual Fueled oven (WKE-04WG-BLK, WKE-04WG-RED) |
| Output | 33,000 BTU |
| Oven temperature on gas | Up to 700°F in the Traditional 25 (WPPO) |
| Fuel | LP (propane) only |
| Gas supply | Supplied regulator and hose; 20 lb cylinder maximum, 12" diameter x 18" tall, DOT (or CAN/CSA-B339), Type 1 outlet, OPD |
| Ignition | Push-and-turn control knob with pulse igniter (AA battery); match lighting as a backup |
| Size | 13" x 9" x 4" |
| Included | Burner, hose and regulator |
| Clearance on gas | 10 ft (3.0 m) from any structure, combustible material or other gas cylinder; 25 ft (7.5 m) from flammable liquids |
| Codes | ANSI Z223.1/NFPA 54, ANSI/NFPA 58; CSA B149.1 and B149.2 in Canada; local codes first |
| Use | Outdoor, residential |
| Warranty | 1-year limited from the date of purchase (gas appliance) |
What's included
- Gas burner
- Hose
- Regulator
Sold separately
- WPPO Traditional 25" Dual Fueled oven, black (WKE-04WG-BLK): the oven this burner fits
- WPPO Traditional 25" Dual Fueled oven, red (WKE-04WG-RED): the same oven in red
- WPPO pro aluminum 4-piece utensil kit (WKPA-01): peels, coal rake and stone brush
- 20 lb LP cylinder: not included
Installation planning
- Fitting the burner: follow the Traditional 25" manual's assembly diagrams. The valve orifice must sit inside the burner tube; WPPO warns that a tube not fitted over the orifice can cause a fire or explosion when lit.
- Gas connection: LP only, with the supplied regulator and hose and a 20 lb cylinder 12" (30.5 cm) across and 18" (45.7 cm) tall, built to DOT (or CAN/CSA-B339) with a Type 1 outlet, safety relief valve and listed overfill protection device. Install to ANSI Z223.1/NFPA 54 and ANSI/NFPA 58, or CSA B149.1 and B149.2 in Canada, with local codes first. With the knob OFF and the tank closed, push the regulator nipple into the tank valve and hand-tighten the coupling nut clockwise to a solid stop.
- Leak test: with the tank open and the knob off, brush a 50/50 mix of mild soap and water on the valve, hose and regulator connections; growing bubbles mean a leak. Close the tank, retighten and test again, and replace parts rather than repairing a leak. Never use a flame, and repeat the test after every refill or tank exchange. If you hear gas rushing at a connection, turn it off at once.
- Lighting: open the cylinder valve, push and turn the knob to LOW to spark the burner and hold it about 5 seconds once lit, then adjust up to HI. If it does not light within 5 seconds, turn it OFF, wait 5 minutes and try again. The igniter in the control knob takes an AA battery; a lit match at the burner pipe also works.
- Location: outdoors only, 10 ft (3.0 m) from any structure, wall, combustible material or other gas cylinder and 25 ft (7.5 m) from flammable liquids, never under an overhang or in a garage, porch or covered patio. Keep the hose away from hot surfaces. Wind can blow out the flame: move out of the wind and relight.
- Troubleshooting: if the burner does not light, check that the regulator nut is tight on the tank valve, the tank valve is open (counterclockwise) and the tank is filled, and move out of high wind.
Care: Check the burner flame regularly, and inspect and clean the burner and venturi tubes for insect nests, which can cause a fire under the oven. Inspect the hose and regulator for cuts, wear or leaks before each use and replace a damaged hose before lighting. WPPO advises a yearly service by a gas retailer or qualified technician. When not in use, turn off the knob and tank, disconnect the cylinder and cap the valve; store the cylinder upright outdoors, never in a garage, porch or vehicle, and never keep a spare cylinder under or near the oven.
Warranty
The Traditional 25" manual gives the gas appliance a one-year limited warranty from the date of purchase for the original buyer: defective parts are replaced free and installed by the owner, and labor is not covered. It excludes non-genuine parts, commercial use, shipping damage, alteration, abuse or misuse, installation or labor charges and incidental or consequential damage. WPPO's oven warranty also excludes non-approved appliances or burners, so use WPPO's own burner in its ovens.
Contact WPPO first rather than returning the part to the store: 815-745-1021 (9:00 am to 5:00 pm Central, Monday to Friday) or info@wppollc.com. The full terms are in the Traditional 25" manual and WPPO's Resource Center.
Manuals and documents
- WPPO Traditional 25" Gas/Wood Hybrid user manual (PDF)
- WPPO Gas Burner for Dual Fueled Outdoor Oven product page
- WPPO accessories
- WPPO Resource Center
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.