Features
- Flush ceiling finish: the heater sits up in the recess frame, so only its face shows below the ceiling line.
- Grade 304 stainless: matches the standard Platinum Electric heaters in black or white.
- Sized to each heater: separate kits for the 2300W, 3400W and 4500W heaters.
- Works with standard ceiling linings: 10 to 30 mm (0.4 to 1.2 in.) thick; Bromic advises on thicker ceilings.
- Uses the heater's own bracket: the heater bracket hooks into the recess mounting plate, and the power cable enters through an extra cable gland.
Specifications
| Identification | |
|---|---|
| Brand | Bromic Heating |
| Series | Platinum Smart-Heat Electric, Ceiling Recess Kit (standard clearance) |
| Part numbers | BH3130017 (2300W), BH3130027 (3400W), BH3623000 (4500W, EU/UK/US/CA) |
| Fits | Platinum Smart-Heat Electric Series II 2300W, 3400W and 4500W heaters (heater not included) |
| Material | Brushed stainless steel, grade 304 |
| Ceiling and clearances | |
| Ceiling lining thickness | 10 to 30 mm (0.4 to 1.2 in.); thicker ceilings: contact Bromic |
| Heater face above floor | 2400 mm (94 in.) minimum |
| To nearest wall | 500 mm (20 in.) minimum, on all sides |
| Between heaters | 500 mm (20 in.) minimum, from the heater edge |
| Cut-out and cavity clearances | Shown on the manual's recess diagrams; for the 2300W and 3400W use one clearance option only, never a mix of the two |
| Heater it carries (for structural planning) | |
| 2300W | 840 x 182 x 54 mm (33.0 x 7.0 x 2.0 in.), 7.5 kg (16.5 lb) |
| 3400W | 1275 x 182 x 54 mm (50.2 x 7.0 x 2.0 in.), 10 kg (22 lb) |
| 4500W | 1351 x 257 x 54 mm (53.2 x 10.1 x 2.1 in.), 15 kg (33 lb) |
| Electrical (heater) | |
| Current, 2300W | 11.1 A at 208V; 9.6 A at 220-240V |
| Current, 3400W | 16.3 A at 208V; 14.2 A at 220-240V |
| Current, 4500W | 21.6 A at 208V; 18.8 A at 220-240V |
| Connection | Permanently hard-wired and grounded, by a licensed person |
| Use | Recess installs: land-based and coastal sites only |
What's included
- Ceiling recess frame and the parts and hardware for recessed mounting (Bromic product page)
- Parts the manual's recess steps call for: an extra cable gland, a two-piece recess mounting plate, a bracket end-cap with M5 screws and nuts, straight covers, M6 x 14 mm mounting screws and M4 x 10 mm positioning screws
Bromic does not publish a separate packing list. Not included: the heater and the fasteners into the ceiling structure.
Sold separately
- Heaters: Platinum Electric 2300W, 3400W, 4500W
- Controls: Affinity Smart-Heat On/Off, Affinity Smart-Heat Dimmer or the Bromic manual wall switch kit
- For shallow cavities: Low Clearance Recess Kit
- For Marine heaters: Marine Ceiling Recess Kit
Installation planning
- Installer: a licensed, authorized person, to local electrical codes. The heater is permanently hard-wired to a supply that matches its rating label and is properly grounded. Switch off the power before installation or maintenance.
- Structure: do not cut or notch joists, beams or rafters. Fix the frame at both ends and the center into structural members strong enough to carry the heater (reinforcement may be needed). The locator hole used depends on the ceiling thickness.
- Cavity: keep the clearances to combustibles shown in the manual's recess diagrams. They are fixed minimums and, for the 2300W and 3400W, the two clearance options cannot be combined. Never cover the heater with insulation or similar material, and protect it fully from water from above.
- Height and spacing: heater face at least 2400 mm (94 in.) above the floor, at least 500 mm (20 in.) from the nearest wall on all sides and at least 500 mm (20 in.) between heaters.
- Sequence: cut the opening to the manual's cut-out drawing, fit the recess frame, swap the heater's wall bracket for the extra cable gland, fit the bracket covers and end-cap, add the two-piece mounting plate, make the electrical connection, then raise the heater into the cavity, rotate it level and lower it so the brackets hook into the frame slots.
- Front clearance: Bromic's heater manuals call for 1000 mm (39.4 in.) clear in front of the heater, with combustibles kept at least 1000 mm away.
Care: Switch off and let the heater cool (Bromic says at least 2 hours) before cleaning. Inspect and clean the body and structure at least monthly, and wipe it with a soft damp cloth every two weeks in coastal areas. Do not use steam cleaners or touch the glass surface. Have the heater inspected before use and serviced at least once a year by a qualified, licensed person.
Warranty
Bromic's published warranty page does not list a separate term for recess kits. It covers Platinum Electric heaters for 3 years, for the original owner only, from the date of purchase. Bromic supplies a replacement heater or part; the owner pays service, removal and reinstallation labor, shipping and other costs. Implied warranties are limited to one year. Claims start with the dealer who sold the product. Ask us to confirm the kit's coverage before you order.
Manuals and documents
- Platinum Smart-Heat Electric Series II 2300W / 3400W manual, US version 4 (PDF)
- Platinum Smart-Heat Electric Series II 4500W manual, version 1.3 (PDF)
- Bromic Platinum Electric Recess Kits product page
- Bromic warranty terms
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.