Features
- 7.1 in. cavity: flush-mounts the heater where ceiling space is shallow, within standard joist spacing.
- Integrated cooling fan and frame: keep the recess cavity within temperature limits, on a dedicated always-on supply.
- Works with every Platinum Electric finish: black and white vent covers are both in the box, so the ceiling finish matches your heater.
- Complete recess hardware: recess box, IP cover, terminal box, trims and screws are included; ceiling fasteners are supplied by the installer.
- Separate element control on 4500W: the larger kit has a 12-terminal block and connectors so the 1500W and 3000W elements can run on separate switches.
- Thermal protection: a self-resetting thermal switch must be plugged in for the heater to run, and a manual-reset thermal switch in the terminal box trips on over-temperature.
Specifications
| Identification | |
|---|---|
| Brand | Bromic Heating |
| Series | Platinum Smart-Heat Electric, Low Clearance (LC) Ceiling Recess Kit, standard |
| Part numbers | BH3623009-1 (2300W), BH3623008-1 (3400W), BH3623012-1 (4500W) |
| Fits | Platinum Smart-Heat Electric 2300W, 3400W and 4500W heaters (heater not included) |
| Ceiling cut-out | |
| 2300W | 995 x 240 mm (39.2 x 9.4 in.) |
| 3400W | 1430 x 240 mm (56.3 x 9.4 in.) |
| 4500W | 1550 x 317 mm (61.0 x 12.5 in.) |
| Kit size (L x W x H) | |
| 2300W | 1039 x 261 x 175 mm (40.9 x 10.3 x 6.9 in.) |
| 3400W | 1475 x 261 x 175 mm (58.1 x 10.3 x 6.9 in.) |
| 4500W | 1595 x 338 x 178 mm (62.8 x 13.3 x 7.0 in.) |
| Installed weight with heater (structural planning) | |
| 2300W | 18.5 kg (41 lb) |
| 3400W | 24 kg (53 lb) |
| Clearances | |
| Vertical space above ceiling | 180 mm (7.1 in.) minimum |
| Terminal box end to nearest surface | 200 mm (7.9 in.) minimum |
| Cut-out to nearest wall | 500 mm (19.7 in.) minimum |
| Between heaters | 500 mm (19.7 in.) minimum, from cut-out edge |
| Heater surface to finished floor | 2400 mm minimum |
| Space between joists | 240 mm (9.4 in.) for 2300W and 3400W; 317 mm (12.5 in.) for 4500W |
| Build and electrical | |
| Material | Brushed stainless steel, grade 304 |
| Ceiling thickness | 10 to 30 mm (0.39 to 1.18 in.); thicker ceilings: contact Bromic |
| Fan supply | 100-127V AC 50/60 Hz, 208V AC 60 Hz or 220-240V AC 50/60 Hz; under 1.0 A; constant, unswitched |
| Heater circuit current | 2300W: 11.1 A at 208V, 9.6 A at 220-240V. 3400W: 16.3 A / 14.2 A. 4500W: 21.6 A / 18.8 A (1500W element 7.2 A / 6.3 A; 3000W element 14.4 A / 12.5 A) |
| Cable gland | M16 (2300W, 3400W); M20 (4500W) |
| Minimum heater supply cable length | 800 mm (2300W), 1000 mm (3400W), 1040 mm (4500W) |
| Terminal wire size | 10 AWG (6.0 mm²) maximum |
| Outdoor wiring parts | IPX5 or better |
| Certification | UL certified (Bromic product page) |
What's included
- Ceiling recess box with integrated cooling fan
- IP cover and terminal box
- Black and white vent covers, with vent cover trims
- Standard trim assembly
- Screws: 8 x M3x6, 8 x M4x8, 1 x M6x10
- 3-way WAGO connectors (4500W kit only)
- Installation instructions
Not included: the heater and the fasteners into the ceiling structure.
Sold separately
- Heaters: Platinum Electric 2300W, 3400W, 4500W
- Controls shown in the wiring diagrams: Affinity Smart-Heat Dimmer (1 channel), Affinity Smart-Heat On/Off (2 channel, for separate element control on the 4500W), or a wall switch such as the Bromic manual wall switch kit; Bromic recommends two 20 A switches for the 4500W
Installation planning
- Installer: a licensed, authorized person, to local electrical codes. Disconnect power during installation and maintenance; the heater must be off and cooled for 2 hours before handling. At least two people are needed for the lifting steps (16 kg maximum safe lift per person).
- Structure: do not cut or notch joists, beams or rafters. Fix the recess box with at least 6 suitable fasteners along the long edge (at least 10 into timber members), into material that can carry the assembly; reinforcement may be needed, and the installer confirms the structure can carry the load.
- Cavity: at least 180 mm (7.1 in.) of vertical space, 200 mm (7.9 in.) at the terminal box end and 500 mm (19.7 in.) from the cut-out to the nearest wall. Never cover the kit or heater with insulation or similar material.
- Weather: protect the recess fully from water from above. Standard (grade 304) heaters must not be directly exposed to rain; use the Marine kit and heater for coastal sites.
- Height and spacing: heater surface at least 2400 mm above the finished floor, and at least 500 mm between heaters from the cut-out edge.
- Wiring: the fan supply must be constant and live at all times, not after a switch, so the fan runs independently of the heater. Rest the heater supply cable on the support structure, never on the heater's rear surface. Use outdoor wiring parts rated IPX5 or better; terminals take up to 10 AWG. The 4500W kit can take separate supplies to control each element.
- Thermal switch: plug the self-resetting thermal switch into the terminal box receptacle, or the heater will not run.
Care: Switch off and wait at least 2 hours before cleaning. Clean the exterior every two weeks with a soft, damp cloth, more often in coastal or harsh conditions. Only an authorized, licensed service person may service it; do not run a malfunctioning heater, and have an electrician inspect it before it is used again. A damaged supply cord must be replaced by Bromic, its service agent or a similarly qualified person. If the manual-reset thermal switch in the terminal box trips (often a fan fault or high ambient temperature), reset it by pressing its center button only with the circuit de-energized.
Warranty
Bromic's published warranty page does not list a separate term for recess kits. It covers Platinum Electric heaters for 3 years from purchase, for the original owner, with Bromic supplying a replacement heater or part and the owner paying labor, removal, reinstallation and shipping costs. Claims start with the dealer that sold the heater. Ask us to confirm the kit's coverage before you order.
Manuals and documents
- Platinum Smart-Heat Electric Low Clearance Ceiling Recess installation instructions, REV10 (PDF)
- LCRK Affinity wiring guide, North America (PDF)
- Bromic Platinum Electric Low-Clearance Recess Kit product page
- Bromic warranty terms
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product.