Features
- 160,000 Btu/hr on natural gas: the highest output of Firegear's 10-inch-wide Pro Series flat H systems, for a long linear fire pit or fire table.
- Brass Pro Series H burner with 40 injectors: individual injectors spread the flame along the 60-inch pan instead of feeding from one orifice.
- TPSI safety pilot: a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.
- Complete gas train in the box: Copreci high-capacity valve, 46-inch 1/2-inch stainless flex line, pilot assembly with 48-inch leads, faceplate and fittings.
- Removable pan for service: the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.
- Listed for 0 to 4,500 ft: in the U.S. and Canada, installed to NFPA 54 / ANSI Z223.1 or CSA B149.1 where there is no local code.
Specifications
| Brand | Firegear Outdoors |
|---|---|
| Series | Pro Series linear H burner systems, flat pan, TPSI |
| Model | LOF-6010PS506TPSI-N (natural gas) |
| Type | Linear fire pit burner system: flat pan, burner and ignition |
| Pan size | 60 in. x 10 in. |
| Burner | Pro Series brass H burner, 6-3/4 in. wide, 40 individual injectors (natural gas) |
| Injector size | #68 (0.031 in.), natural gas |
| Output | 160,000 Btu/hr (natural gas) |
| Fuel | Natural gas; ships set for NG and cannot be field converted (propane model LOF-6010PS506TPSI-P, 175,000 Btu/hr) |
| Inlet gas pressure | Natural gas: min 3.5 in. WC, normal 7.0 in. WC, max 10.5 in. WC |
| Ignition | TPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery) |
| Gas valve | Copreci high capacity valve (68001599) with control knob CN-ALHC |
| Gas connection | 1/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1/2 in. male flare fitting on your shut-off valve |
| Pilot leads | 48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them |
| Enclosure ventilation | At least 18 sq. in. of cross ventilation per side |
| Clearances to combustibles | 36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space |
| Elevation | 0 to 4,500 ft (U.S. and Canada) |
| Use | Outdoor use only |
| Installation codes | Local codes; otherwise ANSI Z223.1/NFPA 54 (U.S.) or CSA B149.1 (Canada) |
| Fire media (approx.) | 40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately |
| Not included | Enclosure, manual shut-off valve, vents, fire media |
| Warranty | Firegear limited warranty; see Warranty below |
What's included
- 60 x 10 in. flat pan (78127) with Pro Series natural gas H burner
- Brass burner support and hardware bag (10850), including injector hoods
- Copreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)
- 1/2 in. stainless flex gas line, 46 in. (T-200-9898-46)
- Natural gas pilot assembly with 48 in. leads (PSE-NA495) and 48 in. pilot tube (90-9898-48)
- Manual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab
- TPSI faceplate / control panel (78188)
- Flare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers
- Firegear installation and operating instructions
Sold separately
- A non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the 84 x 24 in. RTF-L8424 and 84 x 34 in. RTF-L8434 (ask us to confirm the fit before you order)
- Manual gas shut-off valve with a 1/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)
- Vent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS / PAVER-VENT-6-LNTS
- FlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation
- Paver control panel plate PAVER-CP-TPSI
- E-Stop 1-hour timer valve ESTOP1-0H
- Fire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona
Installation planning
- Who installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.
- Enclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.
- Ventilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.
- Clearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.
- Gas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3/4 in. black iron pipe and points to NFPA 54 for runs over 20 ft on units above 100,000 Btu; its product guide chart shows 3/4 in. pipe at its 160,000 Btu limit on a 20 ft run, so have a licensed plumber size the line. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.
- Media: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.
- Weather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.
- Lighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.
Care: Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Do not use it if any part has been under water; have a qualified technician replace the affected controls.
Warranty
Firegear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.
Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.
Manuals and documents
- Firegear FPB Pro H-Burner Flat Pan Fire Pits with TPSI System, installation and operating instructions, Rev. C (PDF)
- Firegear product guide 2023: Pro Series linear H systems page 14, media chart page 25, gas pipe sizing page 26 (PDF)
- Firegear Linear H Pro Burner Systems product page
- Firegear current product catalog (online)
- Firegear warranty
Legal disclaimers and warnings
Product packaging, owners' manuals, installation instructions, and/or operating instructions may include more information than what is shown on our website. The content on our site is intended to be used for reference purposes only. Please fully read all included manuals and documentation before installing or using this product. WARNING for California residents: Firegear's instructions carry a California Proposition 65 warning for this product. For more information go to www.P65Warnings.ca.gov.