Skip to product information
1 of 2

Firegear

Firegear Pro Series 60 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-P

Firegear Pro Series 60 x 10-Inch Linear Flat Pan Propane Fire Pit Burner System with TPSI Ignition - LOF-6010PS506TPSI-P

Regular price $2,669.00
Regular price Sale price $2,669.00
Sale Sold out
Free shipping Within the contiguous US
Quantity

Order before noon Pacific Time for same-day shipping.*

Estimated delivery within the contiguous US: 2–3 business days after shipping.

*Monday–Friday, excluding holidays.

Shipping details

Orders placed before 12:00 p.m. Pacific Time Monday–Friday ship the same day, excluding holidays. Orders placed after the cutoff, on weekends, or on holidays ship the next business day.

Delivery within the contiguous US typically takes 2–3 business days after shipping. Saturdays, Sundays, and holidays do not count toward this estimate.

Orders with a subtotal over $199.99 before tax qualify for free base shipping to US destinations. Orders with a subtotal of $199.99 or less before tax have a $29.99 base shipping charge per order.

Additional shipping charges may apply to Alaska, Hawaii, and US territories. We will notify you of any additional charge on a case-by-case basis before shipping. See our shipping policy for details and delivery estimates for these destinations.

View our shipping policy

Ask an Expert

Buy with confidence. Talk to a grill expert today.

Hours

Sales & Support Hours (Pacific)

Sales
Mon–Fri 7am–9pm · Sat 8:30am–5pm · Sun 9:30am–6pm
Support
Mon–Fri 8am–5pm · Sat 8:30am–5pm · Sun 9:30am–6pm

Description

The Firegear Pro Series LOF-6010PS506TPSI-P is a complete linear fire pit burner system for propane: a 60 x 10-inch flat pan carrying a Pro Series brass H burner rated at 175,000 Btu/hr, with a TPSI (thermocouple-piloted safety ignition) standing pilot and a battery push-button spark igniter. It is built to drop into a custom fire pit or fire table enclosure that you or your builder make from non-combustible materials, then cover with lava rock or fire glass.

Firegear's Pro Series H burner uses many individual brass injectors instead of one main orifice, for a full flame along the length of the pan. TPSI is a thermocouple-piloted system: a safety valve shuts off the gas if the pilot flame goes out. You light it at the control knob while pressing the spark button, then turn the knob to ON. Firegear lists TPSI as its most popular and lowest-cost ignition, suited to residential installs. The natural gas version is LOF-6010PS506TPSI-N (160,000 Btu); for a shorter pit see the 48 x 10-inch propane LOF-4810PS406TPSI-P, or browse our fire pit burners and components.

Plan ahead: choose the gas type before you order, because Firegear Pro Series systems are built for one gas and cannot be field converted. The enclosure, a manual shut-off valve at the gas supply, cross ventilation, drainage and fire media are not included, and the propane supply and regulator need to be planned with your gas supplier. The enclosure needs at least 18 sq. in. of cross ventilation on each side, and installation must be done by a qualified installer, service agency or gas supplier.

View full details

Features

  • 175,000 Btu/hr on propane: the highest rating in Firegear's Pro Series flat H TPSI model table, for a long linear fire pit or fire table.
  • Brass Pro Series H burner: many individual brass injectors spread the flame along the 60-inch pan instead of feeding from one orifice.
  • TPSI safety pilot: a thermocouple-piloted valve shuts off the gas if the pilot goes out; the push-button Piezo spark igniter runs on one AAA battery.
  • Gas train in the box: Copreci high-capacity valve, 46-inch 1/2-inch stainless flex line, propane pilot assembly with 48-inch leads, faceplate and fittings.
  • Removable pan for service: the flat pan sits on the enclosure so the burner and pilot can be reached for the annual inspection Firegear calls for.
  • Listed for 0 to 4,500 ft: in the U.S. and Canada, installed to NFPA 54 / ANSI Z223.1 or CSA B149.1 where there is no local code.

Specifications

Brand Firegear Outdoors
Series Pro Series linear H burner systems, flat pan, TPSI
Model LOF-6010PS506TPSI-P (propane)
Type Linear fire pit burner system: flat pan, burner and ignition
Pan size 60 in. x 10 in. (pan 78127)
Burner Pro Series brass H burner, 6-3/4 in. wide, multiple individual brass injectors (propane); burner part FG-PSBR-H50-LP
Injector size #72 (0.025 in.), propane
Output 175,000 Btu/hr (propane)
Fuel Propane; ships set for LP and cannot be field converted
Inlet gas pressure Propane: min 8.0 in. WC, normal 11.0 in. WC, max 13.0 in. WC
Ignition TPSI: standing pilot with thermocouple safety shut-off; push-button Piezo spark igniter (1 AAA battery)
Gas valve Copreci high capacity valve (68001599) with control knob CN-ALHC
Gas connection 1/2 in. stainless flex line, 46 in. (T-200-9898-46), to a 1/2 in. male flare fitting on your shut-off valve
Pilot leads 48 in. pilot tubing and thermocouple leads; mount the control plate within reach of them
Enclosure ventilation At least 18 sq. in. of cross ventilation per side
Clearances to combustibles 36 in. side wall, 120 in. ceiling, 18 in. floor, 8 in. ground level; 36 in. maximum overhang; not for an enclosed space
Elevation 0 to 4,500 ft (U.S. and Canada); above that, input is reduced 4% per 1,000 ft, usually with a smaller orifice
Use Outdoor use only
Installation codes Local codes; otherwise ANSI Z223.1/NFPA 54 (U.S.) or CSA B149.1 (Canada)
Fire media (approx.) 40 lb lava rock, or 80 lb fire glass, or 40 lb lava stones (Firegear media chart for 60 x 10 in. H flat pans); sold separately
Not included Enclosure, manual shut-off valve, vents, fire media; propane tank and regulator not confirmed as included (ask us)
Warranty Firegear limited warranty; see Warranty below

What's included

  • 60 x 10 in. flat pan (78127) with Pro Series propane H burner (FG-PSBR-H50-LP)
  • Brass burner support and hardware bag (10850), including injector hoods
  • Copreci high capacity gas valve (68001599), M15 x 1 lock nut (08032504) and control knob (CN-ALHC)
  • 1/2 in. stainless flex gas line, 46 in. (T-200-9898-46)
  • Propane pilot assembly with 48 in. leads (PES-LP495) and 48 in. pilot tube (90-9898-48)
  • Manual spark ignitor module (3042-RB), 23 in. and 48 in. Piezo extension wires (PIEZO23WH, PIEZO48WH) and ground tab
  • TPSI faceplate / control panel (78188)
  • Flare and pipe fittings: U1-8D-S, 49-88 elbow, U3-8D-S, 46-86, 10858 and 113SS4-D2 nipples, plus stainless screws, nuts and washers
  • Firegear installation and operating instructions

Sold separately

  • A non-combustible enclosure; Firegear's linear ready-to-finish enclosures include the 84 x 24 in. RTF-L8424 and 84 x 34 in. RTF-L8434 (ask us to confirm the fit before you order)
  • Manual gas shut-off valve with a 1/2 in. male flare outlet (Firegear 01-387, 01-487, 01-266 or 01-288)
  • Vent kit VENT-KIT-6X12SS (18 sq. in. per side) or PAVER-VENT-4-LNTS / PAVER-VENT-6-LNTS
  • FlexFrame installation collar FLEXFRAME-SS (2-piece) or FLEXFRAME-SS3 (3-piece), which Firegear highly recommends for every installation
  • Paver control panel plate PAVER-CP-TPSI
  • E-Stop 1-hour timer valve ESTOP1-0H
  • Fire media: lava stones FG-LS50 (50 lb), lava rock FG-LAVA-40 (bag) or FG-LAVA-10 (jug), fire glass in 10 lb jugs; log sets L-SF and L-Sedona

Installation planning

  • Who installs: installation and service must be done by a qualified installer, service agency or the gas supplier, to local codes, or without them to ANSI Z223.1/NFPA 54 or CSA B149.1. Outdoor use only; never in a camper, tent, car, home or other enclosed space.
  • Enclosure: only non-combustible materials may touch any part of the fire pit; the underside may be non-combustible or a flat, level combustible surface that meets the clearances. Set it on a flat, stable, level outdoor surface, not on grass, dirt or rocks. Do not exceed Firegear's maximum opening for this pan (ask us for the figure), keep the pan removable, and do not let the coping or cap overlap the pan lip.
  • Ventilation and drainage: provide at least 18 sq. in. of cross ventilation on each side (for example two 6 x 12 in. vents) and build water drainage into the enclosure. Firegear states that failure to provide proper ventilation can void the warranty.
  • Clearances to combustibles: 36 in. to a side wall, 120 in. to a combustible ceiling (48 and 60 in. models), 18 in. to a combustible floor and 8 in. at ground level, with a 36 in. maximum overhang. These clearances are not for an enclosed space.
  • Gas supply: install a manual shut-off valve (not supplied) at the exterior house wall or supply, with a 1/2 in. male flare outlet for the included 46 in. flex line. Firegear recommends at least 3/4 in. black iron pipe and points to NFPA 54 for sizing; its propane chart lists 189,000 Btu/hr for 1/2 in. pipe and 393,000 Btu/hr for 3/4 in. pipe on a 20 ft run (add about 5 ft per fitting), so have a licensed installer size the line. Plan the propane supply and regulator with your gas supplier: Firegear's instructions do not size the tank or say whether a regulator comes with this system, so ask us before you order. Never store an LP cylinder that is not connected for use near this or any other appliance. Flared joints need no tape or compound; threaded joints need gas-rated tape or sealant. Do not kink the flex line. Isolate the appliance for pressure tests and leak-test every connection with soapy water before use.
  • Media: use 1 to 2 in. lava rock or media (base pieces at least 1 in.), placed loosely by hand, not poured. Cover the burner by no more than 1 in. above the ports, keep the pilot screen hood clear and never block the injectors.
  • Weather: gusts of 25 to 30 mph or more can blow out the pilot, and heavy rain or high humidity can cause pilot outages and popping media; after lighting in wet weather, let the media dry at least 30 minutes while watching from a distance.
  • Lighting: hold the red spark button, press and turn the knob to PILOT and hold 30 to 60 seconds, release the button once the pilot lights, then turn to ON. If the pilot will not stay lit, turn to OFF and wait 5 minutes before trying again.

Care: Have a qualified service person inspect and clean the system before first use and at least once a year. Keep the control compartment, burners and air passages clean, clean the brass injectors with compressed air (wear eye protection), check for insect nests, and inspect the gas connection before each use. Cover the fire pit when not in use (remove any combustible cover before lighting) and let it dry after heavy rain. Stainless parts can turn gold or brown with heat, which is normal. Store it indoors only after disconnecting it from the gas supply. Do not use it if any part has been under water; have a qualified technician replace the affected controls.

Warranty

Firegear Outdoors warrants its products to the end user against defects in material and workmanship, from the date of sale to the end user. Firegear's warranty lists terms by component (for example, gas valves, pilot assemblies and controls at 5 years for consumer use and 2 years for commercial use); ask us to confirm the term for the burner and pan before you file.

Coverage is for the original purchaser, with a bill of sale or payment record. Claims go through the dealer to Firegear Technical Support, which confirms the defect and replaces approved parts (a returned part needs an RMA, valid for 30 days); report missing or damaged parts to Firegear as soon as possible, and out-of-box claims within 30 days of purchase and before installation. Not covered: accident, misuse, improper installation or maintenance, relocation, severe weather, chemical exposure such as chlorine or salt, and labor, travel and diagnostic costs. Any tampering or modification, or installation without proper ventilation, voids the warranty. Full terms are on Firegear's warranty page.

Manuals and documents